The DOI matches its Crossref record, with a small difference in title or year; 14 of the 14 references it cites were found in a registry or an index.
Perception of Atrial Fibrillation Before and After Radiofrequency Catheter Ablation: Relevance of Asymptomatic Arrhythmia Recurrence
Abstract
Background— The objective of this study was to assess the incidence and impact of asymptomatic arrhythmia in patients with highly symptomatic atrial fibrillation (AF) who qualified for radiofrequency (RF) catheter ablation. Methods and Results— In this prospective study, 114 patients with at least 3 documented AF episodes together with corresponding symptoms and an ineffective trial of at least 1 antiarrhythmic drug were selected for RF ablation. With the use of CARTO, circumferential lesions around the pulmonary veins and linear lesions at the roof of the left atrium and along the left atrial isthmus were placed. A continuous, 7-day, Holter session was recorded before ablation, right after ablation, and after 3, 6, and 12 months of follow-up. During each 7-day Holter monitoring, the patients recorded quality and duration of any complaints by using a detailed symptom log. More than 70 000 hours of ECG recording were analyzed. In the 7-day Holter records before ablation, 92 of 114 patients (81%) had documented AF episodes. All episodes were symptomatic in 35 patients (38%). In 52 patients (57%), both symptomatic and asymptomatic episodes were recorded, whereas in 5 patients (5%), all documented AF episodes were asymptomatic. After ablation, the percentage of patients with only asymptomatic AF recurrences increased to 37% ( P <0.05) at the 6-month follow-up. An analysis of patient characteristics and arrhythmia patterns failed to identify a specific subset who were at high risk for the development of asymptomatic AF. Conclusions— Even in patients presenting with highly symptomatic AF, asymptomatic episodes may occur and significantly increase after catheter ablation. A symptom-only–based follow-up would substantially overestimate the success rate. Objective measures such as long-term Holter monitoring are needed to identify asymptomatic AF recurrences after ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Indeed, catheter ablation may increase the proportion of AF events that are asymptomatic, probably by alteration of cardiac neural element (Hindricks et al., 2005).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Hindricks et al., 2005
Experimental — accuracy not yet measuredIn the citing paper
“Patient should also be aware that symptomatic and asymptomatic AF recurrences are frequent after catheter ablation.119,781,782”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [119]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 779
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627 · cited 1×
“For patients with documented AF, the median total arrhythmia duration during the 7-day ECG periods measured 38 (10, 133) hours before ablation and postinterventionally declined to 36 (22, 79) hours immediately after ablation (P 0.”
BackgroundLong-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 478
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339
Kottkamp, H., Tanner, H., Kobza, R., Schirdewahn, P., Dorszewski, A., Gerds‐Li, J., Carbucicchio, C., Piorkowski, C., & Hindricks, G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.049 · Cited by 196
Self-citationClinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers
Gerstenfeld, E. P., Guerra, P. G., SPARKS, P. B., Hattori, K., & Lesh, M. D. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00900.x · Cited by 191
Asymptomatic or “Silent” Atrial Fibrillation
Page, R. L., Tilsch, T. W., Connolly, S. J., Schnell, D., Marcello, S. R., Wilkinson, W. E., & Pritchett, E. L. C. (2003) · Circulation · doi:10.1161/01.cir.0000051455.44919.73 · Cited by 165
Flagged first, then by citations
Research works printed but not linked: 1
- 10.1161/circ.89.1.8281651 · DOI
Cited by
Sorted by citations
Items 201–300 of 507
Kochhäuser, S., Alipour, P., Haig-Carter, T., Trought, K., Hache, P., Khaykin, Y., Wulffhart, Z. A., Pantano, A. A., Tsang, B., Birnie, D. H., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13138 · Cited by 21
Large‐scale screening studies for atrial fibrillation – is it worth the effort?
Engdahl, J., & Rosenqvist, M. (2021) · Journal of Internal Medicine · doi:10.1111/joim.13217 · Cited by 22
Pulmonary Vein Isolation With and Without Posterior Wall Isolation in Paroxysmal Atrial Fibrillation
Aryana, A., Thiemann, A. M., Pujara, D. K., Cossette, L. L., Allen, S. L., Bowers, M. R., Gandhavadi, M. B., Heath, R. R., Trivedi, A. D., O’Neill, P. G., et al. (2023) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.01.014 · Cited by 22
Long-term Success and Follow-up After Atrial Fibrillation Ablation
Kircher, S., Hindricks, G., & Sommer, P. (2012) · Current Cardiology Reviews · doi:10.2174/157340312803760758 · Cited by 21
Self-citationWinkle, R. A., Mead, R. H., Engel, G., Kong, M. H., & Patrawala, R. A. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.05.012 · Cited by 20
Balabanski, T., Brugada, J., Arbelo, E., Laroche, C., Maggioni, A. P., Blomström‐Lundqvist, C., Kautzner, J., Tavazzi, L., Tritto, M. V., Kułakowski, P., et al. (2019) · EP Europace · doi:10.1093/europace/euz216 · Cited by 20
A probability density function method for detecting atrial fibrillation using R – R intervals
Lu, H., Ying, S., Min, L., Li, P., & Zheng, Z. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.04.013 · Cited by 20
Detecting and monitoring arrhythmia recurrence following catheter ablation of atrial fibrillation
Ajijola, O. A., Boyle, N. G., & Shivkumar, K. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00090 · Cited by 20
Verdoia, M., Schaffer, A., Pergolini, P., Rolla, R., Barbieri, L., Bellomo, G., Sinigaglia, F., Marino, P. N., Suryapranata, H., & Luca, G. D. (2015) · Journal of Cardiovascular Pharmacology · doi:10.1097/fjc.0000000000000240 · Cited by 20
Defining endpoints in clinical trials on atrial fibrillation
Camm, A. J., & Reiffel, J. A. (2008) · European Heart Journal Supplements · doi:10.1093/eurheartj/sun028 · Cited by 20
Nergårdh, A., & Frick, M. (2006) · Heart · doi:10.1136/hrt.2005.082156 · Cited by 20
Atrial fibrillation detection algorithms for very long term ECG monitoring
PETRUCCI, E., Balian, V., Filippini, G., & Mainardi, L. T. (2005) · Computers in cardiology · doi:10.1109/cic.2005.1588178 · Cited by 20
EURASIAN CLINICAL RECOMMENDATIONS ON DIAGNOSIS AND TREATMENT OF ATRIAL FIBRILLATION
Sp, G., Панченко, Е. П., Станиславовна, К. Е., Laiovich, L. I., Maykov, E. B., Mironov, N. Y., & Shakhmatova, O. O. (2019) · Eurasian heart journal · doi:10.38109/2225-1685-2019-4-4-85 · Cited by 21
Informe del Grupo de Trabajo para la elaboración de guías de práctica clínica del American College of Cardiology y de la American Heart Association, del Comité de Guías de Práctica Clínica de la Sociedad Europea de Cardiología (comité de redacción para la revisión de la Guía de práctica clínica sobre el manejo de pacientes con fibrilación auricular, 2., & Desarrollado en colaboración con las asociaciones European Heart Rhythm Association y Heart Rhythm Society (2006) · Revista Española de Cardiología · doi:10.1157/13096583 · Cited by 20
Page, R. L., Pritchett, E. L. C., Connolly, S. J., Wilkinson, W. E., & For the SVA‐4 Investigators (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00985.x · Cited by 19
Yamada, T., Yoshida, N., Murakami, Y., Okada, T., Yoshida, Y., Muto, M., Inden, Y., & Murohara, T. (2009) · EP Europace · doi:10.1093/europace/eup330 · Cited by 19
Santini, M., Loiaconi, V., Tocco, M. P., Mele, F., & Pandozi, C. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9650-5 · Cited by 18
Luik, A., Merkel, M., Hoeren, D., Riexinger, T., Kieser, M., & Schmitt, C. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.01.008 · Cited by 18
Quality of Life after Surgical Ablation of Persistent Atrial Fibrillation: A Prospective Evaluation
Chernyavskiy, A. М., Карева, Ю. Е., Алексеевна, П. И., Собирович, Р. С., Pokushalov, E. A., & Romanov, A. B. (2015) · Heart Lung and Circulation · doi:10.1016/j.hlc.2015.08.015 · Cited by 18
Forkmann, M., Schwab, C., Edler, D., Vevecka, A. H., Butz, S., Haller, B., Brachmann, J., & Busch, S. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14109 · Cited by 18
Left Atrial Volume as a Biomarker of Atrial Fibrillation at Routine Chest CT: Deep Learning Approach
Bratt, A. K., Guenther, Z. D., Hahn, L. D., Kadoch, M. A., Adams, P. L., Leung, A. N. C., & Guo, H. H. (2019) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.2019190057 · Cited by 17
Katritsis, D. G., Ellenbogen, K. A., Giazitzoglou, E., Sougiannis, D., Paxinos, G., Fragakis, N., & Camm, A. J. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9247-9 · Cited by 18
Cardioversion of Atrial Fibrillation for Maintenance of Sinus Rhythm: A Road to Nowhere
Wyse, D. G. (2009) · Circulation · doi:10.1161/circulationaha.109.884387 · Cited by 18
JCS / JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia
Takase, B., Ikeda, T., Shimizu, W., Abe, H., Aiba, T., Chinushi, M., Koba, S., KUSANO, K. F., Niwano, S., Takahashi, N., et al. (2024) · Journal of Arrhythmia · doi:10.1002/joa3.13052 · Cited by 19
Jędrzejczyk‐Patej, E., Lenarczyk, R., Mazurek, M., Liberska, A., Przybylska-Siedlecka, K., Podolecki, T., Kowalczyk, J. P., Sokal, A., Leopold-Jadczyk, A., Kowalski, O., et al. (2015) · EP Europace · doi:10.1093/europace/euv095 · Cited by 17
Moreira, W., Timmermans, C. C., Wellens, H. J. J., Mizusawa, Y., Perez, D., Philippens, S., & Rodriguez, L. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-007-9197-7 · Cited by 17
Lobodzinski, S. M., & Laks, M. M. (2006) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.05.016 · Cited by 17
Yoshida, N., Yamada, T., Murakami, Y., Okada, T., Ninomiya, Y., Toyama, J., Yoshida, Y., Tsuboi, N., Muto, M., Inden, Y., et al. (2009) · Circulation Journal · doi:10.1253/circj.cj-08-0599 · Cited by 17
Adverse Clinical Events during Long-Term Follow-Up After Catheter Ablation of Atrial Fibrillation
Arai, M., Okumura, Y., Nagashima, K., Watanabe, I., Watanabe, R., Wakamatsu, Y., Otsuka, N., Yagyu, S., Kurokawa, S., Ohkubo, K., et al. (2019) · International Heart Journal · doi:10.1536/ihj.18-517 · Cited by 16
Assessment and management of asymptomatic atrial fibrillation
Andrade, J. G., Deyell, M. W., Bennett, R. G., & Macle, L. (2023) · Heart · doi:10.1136/heartjnl-2023-322428 · Cited by 16
Looi, K., Gajendragadkar, P. R., Taha, T., Elsik, M., Scully, E., Heck, P. M., Fynn, S. P., Virdee, M., & Begley, D. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9744-8 · Cited by 16
Eckardt, L., Deneke, T., Diener, H., Hindricks, G., Hoffmeister, H. M., Hohnloser, S. H., Kirchhof, P. F., & Stellbrink, C. (2017) · Der Kardiologe · doi:10.1007/s12181-017-0141-5 · Cited by 16
Self-citationDeng, L., Xiao, Y., & Hong, H. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13494 · Cited by 16
Symptoms and health‐related quality of life 5 years after catheter ablation of atrial fibrillation
Walfridsson, U., Jönsson, A. H., Karlsson, L., Liuba, I., Almroth, H., Sandgren, E., Walfridsson, H., & Charitakis, E. (2021) · Clinical Cardiology · doi:10.1002/clc.23752 · Cited by 16
Manganiello, S., Anselmino, M., Amellone, C., Pelissero, E., Giuggia, M., Trapani, G. D., GIORDANO, B., SENATORE, G., & Gaïta, F. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12387 · Cited by 16
What Does The Blanking Period Blank?
Mariani, M. A., Pozzoli, A., Maat, G. D., Alfieri, O., & Benussi, S. (2015) · PubMed Central · doi:10.4022/jafib.1268 · Cited by 16
Romero, I. (2013) · Cardiology in Review · doi:10.1097/crd.0b013e31828a8294 · Cited by 16
Hermans, A. N. L., Pluymaekers, N. A. H. A., Lankveld, T., van Mourik, M. J. W., Zeemering, S., Dinh, T., den Uijl, D. W., LUERMANS, J. G. L. M., Vernooy, K., Crijns, H. J. G. M., et al. (2021) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2021.100870 · Cited by 15
Pezawas, T., Ristl, R., Schukro, C., & Schmidinger, H. (2015) · Clinical Research in Cardiology · doi:10.1007/s00392-015-0879-3 · Cited by 15
Savelieva, I., Kirchhof, P. F., Danchin, N., de Graeff, P. A., & Camm, A. J. (2011) · EP Europace · doi:10.1093/europace/eur181 · Cited by 15
Atarashi, H., Ogawa, S., & Inoue, H. (2008) · Journal of Cardiology · doi:10.1016/j.jjcc.2008.06.006 · Cited by 15
Inhibition of the Renin-Angiotensin System for Prevention of Atrial Fibrillation
Zografos, T. A., & Katritsis, D. G. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02832.x · Cited by 15
Management of Atrial Fibrillation
Watson, T., & Lip, G. Y. H. (2006) · Herz · doi:10.1007/s00059-006-2932-5 · Cited by 15
Continuous rhythm monitoring‐guided anticoagulation after atrial fibrillation ablation
Pothineni, N. V. K., Amankwah, N., Santangeli, P., Schaller, R. D., Supple, G. E., Deo, R., Nazarian, S., Garcia, F. C., Dixit, S., Callans, D. J., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14864 · Cited by 14
Schwab, C., Anić, A., Farkowski, M. M., Palmero, M. J. G., Iliodromitis, K. E., Jubele, K., Providencia, R. A., Chun, K. R. J., & Bovéda, S. (2022) · EP Europace · doi:10.1093/europace/euac194 · Cited by 14
Senoo, K., Yukawa, A., Ohkura, T., Iwakoshi, H., Nishimura, T., Shimoo, S., Inoue, K., Sakatani, T., Kakita, K., Hattori, T., et al. (2023) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2023.101177 · Cited by 15
Veasey, R. A., Segal, O. R., Large, J., Lewis, M. E., Trivedi, U., Cohen, A. S., Hyde, J., & Sulke, A. N. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9576-y · Cited by 14
Zado, E. S., Pammer, M. R., Parham, T., Lin, D., Frankel, D. S., Dixit, S., & Marchlinski, F. E. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13859 · Cited by 14
Han, J., Li, G., Zhang, D., Wang, X., & Guo, X. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.907817 · Cited by 14
Nagarakanti, R., Saksena, S. V., Hettrick, D. A., Koehler, J. L., Grammatico, A., & Padeletti, L. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9601-1 · Cited by 14
Gone Fishing (for Silent Atrial Fibrillation)
Ahmad, Y., & Kirchhof, P. F. (2013) · Circulation · doi:10.1161/circulationaha.112.000985 · Cited by 14
Heeger, C.-H. H., Tscholl, V., Salloum, O., Wißner, E., Fink, T., Rottner, L., Wohlmuth, P., Bellmann, B., Roser, M., Mathew, S., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.07.016 · Cited by 13
Singer, D. E., Atlas, S. J., Go, A. S., Lópes, R. D., Lubitz, S. A., McManus, D. D., Revkin, J. H., Mills, D. J., Crosson, L. A., Lenane, J. C., et al. (2022) · American Heart Journal · doi:10.1016/j.ahj.2022.04.005 · Cited by 13
Atrial Fibrillation Ablation: Indications, Emerging Techniques, and Follow-Up
Gerstenfeld, E. P., & Duggirala, S. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.07.008 · Cited by 13
Epidemiología de la fibrilación auricular y comorbilidades asociadas
García‐Seara, J., & González‐Juanatey, J. R. (2012) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(12)70045-6 · Cited by 13
Relevance of Monitoring Atrial Fibrillation in Clinical Practice
Lewalter, T., & Boriani, G. (2012) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2012.1.54 · Cited by 13
Kimura, T., Aizawa, Y., Kurata, N., Nakajima, K., Kashimura, S., Kunitomi, A., Nishiyama, T., Katsumata, Y., Nishiyama, N., Fukumoto, K., et al. (2016) · Heart and Vessels · doi:10.1007/s00380-016-0866-2 · Cited by 12
Kistler, P. M., Sanders, P., Amarena, J., Bain, C., Chia, K. K. M., Choo, W. K., Eslick, A., Hall, T. L., Hopper, I., Kotschet, E., et al. (2024) · Heart Lung and Circulation · doi:10.1016/j.hlc.2023.12.024 · Cited by 12
Ablation of atrial fibrillation
Wright, M. J., & Narayan, S. M. (2014) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2014.11.009 · Cited by 12
Perego, G. B., Iacopino, S., Molon, G., Arena, G., Verlato, R., Pieragnoli, P., Curnis, A., Allocca, G., Nicolis, D., Sciarra, L., et al. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.02.015 · Cited by 12
Wakamatsu, Y., Nagashima, K., Watanabe, R., Arai, M., Yokoyama, K., Matsumoto, N., Otsuka, T., Suzuki, S. S., Hirata, A., Murakami, M., et al. (2020) · International Heart Journal · doi:10.1536/ihj.20-335 · Cited by 12
Cecchini, F., Mugnai, G., Iacopino, S., Abugattás-Torres, J. P., Adriaenssens, B., Housari, M. A., Almorad, A., Bala, G., Bisignani, A., de Asmundis, C., et al. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01313-x · Cited by 12
Björkenheim, A., Brandes, A., Chemnitz, A., Magnuson, A., Edvardsson, N. G., & Poçi, D. (2016) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12916 · Cited by 12
Smith, D., Lip, G. Y. H., & Lane, D. A. (2010) · EP Europace · doi:10.1093/europace/euq083 · Cited by 12
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.07.001 · Cited by 11
Self-citationMorttada, A. (2018) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2012 · Cited by 11
Novedades en estimulación cardiaca
de Carranza, M. J. S.-T., Fidalgo-Andrés, M. L., Ferrer, J. M., & Mateas, F. R. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2011.11.017 · Cited by 11
Ablation vs. drug use for atrial fibrillation
Jaı̈s, P., & Packer, D. L. (2007) · European Heart Journal Supplements · doi:10.1093/eurheartj/sum050 · Cited by 11
A Critical Perspective on the Role of Catheter Ablation in Management of Atrial Fibrillation
Wyse, D. G. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.03.001 · Cited by 10
Long-term clinical outcome of patients who failed catheter ablation of atrial fibrillation
Bottoni, N., Bertaglia, E., Donateo, P., Quartieri, F., Iori, M., Maggi, R., Zoppo, F., BRANDOLINO, G., & Brignole, M. (2014) · EP Europace · doi:10.1093/europace/euu229 · Cited by 10
Pezawas, T., Ristl, R., Bilinski, M., Schukro, C., & Schmidinger, H. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.03.013 · Cited by 10
Hafner, F., Seinost, G., Gary, T., Froehlich, H., Pilger, E., & Brodmann, M. (2010) · European Radiology · doi:10.1007/s00330-010-1801-z · Cited by 10
Patel, N. N., Chung, E. H., Mounsey, J. P., Schwartz, J., Pursell, I. W., & Gehi, A. K. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.02.022 · Cited by 10
Is Time to First Recurrence of Atrial Fibrillation Correlated With Atrial Fibrillation Burden?
Pérez, F. J., Lung, T., Ellenbogen, K. A., & Wood, M. A. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.050 · Cited by 10
Pharmacologic approaches to rhythm versus rate control in atrial fibrillation—where are we now?
Wyse, D. G. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.12.001 · Cited by 10
Ha, A. C. T., & Dorian, P. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9721-2 · Cited by 10
Surgical Treatment of Atrial Fibrillation
Abo‐Salem, E., Lockwood, D. J., Boersma, L. V. A., Deneke, T., Pison, L., PAONE, R. F., & NUGENT, K. M. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12731 · Cited by 10
Hæusler, K. G., Koch, L., Ueberreiter, J., Endres, M., Schultheiss, H., Heuschmann, P. U., Schirdewan, A., & Fiebach, J. B. (2010) · BMC Neurology · doi:10.1186/1471-2377-10-63 · Cited by 10
Fleury, Q., Dubois, R., Christophle-Boulard, S., Extramiana, F., & Maison‐Blanche, P. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.09.007 · Cited by 9
Jackman, W. M., Stevenson, W. G., Estes, M., Richard, L., Ezekowitz, M. D., Curtis, A. B., January, C. T., Ellenbogen, K. A., & James, E. A. (2011) · Cited by 9
Osaka, Y., Takigawa, M., Takahashi, A., Kuwahara, T., Okubo, K., Takahashi, Y., Tanaka, Y., Kawaguchi, N., Yamao, K., Watari, Y., et al. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.07.009 · Cited by 9
Choudhury, R., Coutiño, H., Darciuc, R., Ströker, E., Regibus, V. D., Mugnai, G., Paparella, G., Terasawa, M., Varnavas, V., Salghetti, F., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.08.015 · Cited by 10
Advances in atrial fibrillation ablation.
Darge, A., Reynolds, M. R., & Germano, J. J. (2009) · PubMed · Cited by 9
Cardioversion for Atrial Fibrillation: Does Inflammation Matter?
Watson, T., Kakar, P., & Lip, G. Y. H. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.12.089 · Cited by 9
Pratola, C., BALDO, E., Notarstefano, P., Toselli, T., & Ferrari, R. (2008) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e3280bad879 · Cited by 9
Brugada-like electrocardiogram detected after reconstructive operation for oesophageal cancer
Sasaki, A., & Nakazato, Y. (2010) · EP Europace · doi:10.1093/europace/euq256 · Cited by 9
Non-invasive Electronic Biosensor Circuits and Systems
Gargiulo, G. D., Bifulco, P., Rafael, A., Cesarelli, M., Jin, C. T., McEwan, A. L., & van, A. (2010) · InTech eBooks · doi:10.5772/7027 · Cited by 10
Shah, D. C. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn108 · Cited by 9
Atlas, S. J., Ashburner, J. M., Chang, Y., Borowsky, L. H., Ellinor, P. T., McManus, D. D., Lubitz, S. A., & Singer, D. E. (2023) · BMC Family Practice · doi:10.1186/s12875-023-02087-5 · Cited by 8
Skin sympathetic nerve activity in symptomatic and asymptomatic paroxysmal atrial fibrillation
Mao, J., Liu, X., Kote, A., Andersson, K. T., Li, X., Albert, C. M., & Chen, P. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.06.015 · Cited by 8
Catheter ablation for chronic atrial fibrillation
Oral, H. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.008 · Cited by 8
Kim, D., Lee, D. I., Ahn, J., Lee, K., Roh, S., Shim, J., Choi, J., & Kim, Y. (2018) · PLoS ONE · doi:10.1371/journal.pone.0201061 · Cited by 8
Maj, R., Ceglia, S. D., Piazzi, E., Pozzi, M., Montemerlo, E., Casiraghi, M., Fienga, M., Gressoni, S., & Rovaris, G. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14998 · Cited by 8
Maagh, P., Bracht, M. V., Butz, T., Trappe, H., & Meißner, A. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9498-0 · Cited by 8
Simulation of monitoring strategies for atrial arrhythmia detection.
Censi, F., Calcagnini, G., Mattei, E., Gargaro, A., BIANCALANA, G., & Capucci, A. (2013) · PubMed · doi:10.4415/ann_13_02_09 · Cited by 8
“Spot” ECGs Underestimate Atrial Fibrillation Recurrence after Surgical Ablation
Puskas, J. D., Corvera, J. S., Neill, A. A., Kilgo, P., Vassiliades, T. A., & Guyton, R. A. (2008) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e318164aa89 · Cited by 7
Rybak, K., D´Ancona, G., Glück, S., Haerer, W., Goss, F., & for the SPIDER-AF Investigators (2023) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02283-4 · Cited by 7
Tang, X. W., Wang, J., Ouyang, X., Chen, Q., Dong, R., Luo, Y., Zhong, J., Huang, Z., Peng, L., Xie, X., et al. (2024) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.123.012486 · Cited by 7
The Year in Review of Clinical Cardiac Electrophysiology
Marcus, G. M., Keung, E. C., & Scheinman, M. M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.062 · Cited by 7
Böhm, A., Urban, Ľ., Tóthová, Ľ., Bachárová, L., Musil, P., Kyselovič, J., Michalek, P., Uher, T., Bezák, B., Olejník, P., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-00972-6 · Cited by 7
Metadata
- Authors
- Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H.
- Affiliations
- Leipzig University (DE)
- From the Heart Center, Department of Electrophysiology, University of Leipzig, Leipzig, Germany.
- ORCID
- Venue
- Circulation
- Published
- 2005-07-19
- Volume
- 112
- Issue
- 3
- Pages
- 307-313
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1988904908
- Cited by
- 506
- References
- 14
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 9 · 2023: 11 · 2022: 14 · 2021: 14 · 2020: 15 · 2019: 20 · 2018: 15 · 2017: 18 · 2016: 19 · 2015: 17 · 2014: 34 · 2013: 28 · 2012: 37
- FWCI
- 27.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, asymptomatic atrial fibrillation, radiofrequency catheter ablation, atrial fibrillation recurrence, Holter monitoring, pulmonary vein isolation, antiarrhythmic drug failure, long-term follow-up
- MeSH terms
- Adrenergic beta-Antagonists, Adult, Aged, Anti-Arrhythmia Agents, Atrial Fibrillation, Atrial Flutter, Electrocardiography, Female, Heart Rate, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review