Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 459

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients

Khambadkone, Sachin, Coats, Louise, Taylor, Andrew, Boudjemline, Younes, Derrick, Graham, Tsang, Victor, Cooper, Jeffrey, Muthurangu, Vivek, Hegde, Sanjeet R., Razavi, Reza S., Pellerin, Denis, Deanfield, John, Bonhoeffer, Philipp·2005·Circulation

Abstract

Background— Right ventricular outflow tract (RVOT) reconstruction with valved conduits in infancy and childhood leads to reintervention for pulmonary regurgitation and stenosis in later life. Methods and Results— Patients with pulmonary regurgitation with or without stenosis after repair of congenital heart disease had percutaneous pulmonary valve implantation (PPVI). Mortality, hemodynamic improvement, freedom from explantation, and subjective and objective changes in exercise tolerance were end points. PPVI was performed successfully in 58 patients, 32 male, with a median age of 16 years and median weight of 56 kg. The majority had a variant of tetralogy of Fallot (n=36), or transposition of the great arteries, ventricular septal defect with pulmonary stenosis (n=8). The right ventricular (RV) pressure (64.4±17.2 to 50.4±14 mm Hg, P <0.001), RVOT gradient (33±24.6 to 19.5±15.3, P <0.001), and pulmonary regurgitation (PR) (grade 2 of greater before, none greater than grade 2 after, P <0.001) decreased significantly after PPVI. MRI showed significant reduction in PR fraction (21±13% versus 3±4%, P <0.001) and in RV end-diastolic volume (EDV) (94±28 versus 82±24 mL · beat −1 · m −2 , P <0.001) and a significant increase in left ventricular EDV (64±12 versus 71±13 mL · beat −1 · m −2 , P =0.005) and effective RV stroke volume (37±7 versus 42±9 mL · beat −1 · m −2 , P =0.006) in 28 patients (age 19±8 years). A further 16 subjects, on metabolic exercise testing, showed significant improvement in V̇ o 2 max (26±7 versus 29±6 mL · kg −1 · min −1 , P <0.001). There was no mortality. Conclusions— PPVI is feasible at low risk, with quantifiable improvement in MRI-defined ventricular parameters and pulmonary regurgitation, and results in subjective and objective improvement in exercise capacity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.523266

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 459

Metadata

Authors
Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., Pellerin, D., Deanfield, J., & Bonhoeffer, P.
Venue
Circulation
Published
2005-08-23
Volume
112
Issue
8
Pages
1189-1197
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2110917599
Cited by
459
References
1
FWCI
21.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients. https://app.cochat.ai/papers/10.1161/circulationaha.104.523266
The paper
Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., Pellerin, D., Deanfield, J., & Bonhoeffer, P. (2005). Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients. Circulation. https://doi.org/10.1161/circulationaha.104.523266

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.