The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients
Abstract
Background— Right ventricular outflow tract (RVOT) reconstruction with valved conduits in infancy and childhood leads to reintervention for pulmonary regurgitation and stenosis in later life. Methods and Results— Patients with pulmonary regurgitation with or without stenosis after repair of congenital heart disease had percutaneous pulmonary valve implantation (PPVI). Mortality, hemodynamic improvement, freedom from explantation, and subjective and objective changes in exercise tolerance were end points. PPVI was performed successfully in 58 patients, 32 male, with a median age of 16 years and median weight of 56 kg. The majority had a variant of tetralogy of Fallot (n=36), or transposition of the great arteries, ventricular septal defect with pulmonary stenosis (n=8). The right ventricular (RV) pressure (64.4±17.2 to 50.4±14 mm Hg, P <0.001), RVOT gradient (33±24.6 to 19.5±15.3, P <0.001), and pulmonary regurgitation (PR) (grade 2 of greater before, none greater than grade 2 after, P <0.001) decreased significantly after PPVI. MRI showed significant reduction in PR fraction (21±13% versus 3±4%, P <0.001) and in RV end-diastolic volume (EDV) (94±28 versus 82±24 mL · beat −1 · m −2 , P <0.001) and a significant increase in left ventricular EDV (64±12 versus 71±13 mL · beat −1 · m −2 , P =0.005) and effective RV stroke volume (37±7 versus 42±9 mL · beat −1 · m −2 , P =0.006) in 28 patients (age 19±8 years). A further 16 subjects, on metabolic exercise testing, showed significant improvement in V̇ o 2 max (26±7 versus 29±6 mL · kg −1 · min −1 , P <0.001). There was no mortality. Conclusions— PPVI is feasible at low risk, with quantifiable improvement in MRI-defined ventricular parameters and pulmonary regurgitation, and results in subjective and objective improvement in exercise capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Merckx, J., Aggoun, Y., Bonnet, D., Acar, P., Le Bidois, J., Sidi, D., & Kachaner, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02844-0 · Cited by 1,095
Self-citationDavlouros, P. A., Kilner, P. J., Hornung, T. S., Li, W., Francis, J. M., Moon, J. C. C., Smith, G. C., Tat, T., Pennell, D. J., & Gatzoulis, M. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02566-4 · Cited by 553
Therrien, J., Siu, S. C., McLaughlin, P. R., Liu, P. P., Williams, W. G., & Webb, G. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00930-x · Cited by 543
Therrien, J., Siu, S. C., Harris, L., Dore, A., Niwa, K., Janousek, J., Williams, W. G., Webb, G., & Gatzoulis, M. A. (2001) · Circulation · doi:10.1161/01.cir.103.20.2489 · Cited by 467
Vliegen, H. W., van Straten, A., de Roos, A., Roest, A. A. W., Schoof, P. H., Zwinderman, A. H., Ottenkamp, J., van der Wall, E. E., & Hazekamp, M. G. (2002) · Circulation · doi:10.1161/01.cir.0000030995.59403.f8 · Cited by 372
Transcatheter Implantation of a Bovine Valve in Pulmonary Position: A Lamb Study
Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Hausse, A. O., Aggoun, Y., Bonnet, D., Sidi, D., & Kachaner, J. (2000) · Circulation · doi:10.1161/01.cir.102.7.813 · Cited by 320
Self-citationRASTELLI, G. C., WALLACE, R. B., & ONGLEY, P. A. (1969) · Circulation · doi:10.1161/01.cir.39.1.83 · Cited by 307
Percutaneous insertion of the pulmonary valve
Bonhoeffer, P., Boudjemline, Y., Qureshi, S. A., Le Bidois, J., Iserin, L., Acar, P., Merckx, J., Kachaner, J., & Sidi, D. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01822-3 · Cited by 307
Self-citationLate pulmonary valve replacement after repair of tetralogy of Fallot
Discigil, B., Dearani, J. A., Puga, F. J., Schaff, H. V., Hagler, D. J., Warnes, C. A., & Danielson, G. K. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.111209 · Cited by 276
Cited by
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Apitz, C., Webb, G. D., & Redington, A. N. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60657-7 · Cited by 653
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
McElhinney, D. B., Hellenbrand, W. E., Zahn, E. M., Jones, T. K., Cheatham, J. P., Lock, J. E., & Vincent, J. A. (2010) · Circulation · doi:10.1161/circulationaha.109.921692 · Cited by 577
Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart Valves
Webb, J. G., Wood, D. A., Ye, J., Gurvitch, R., Masson, J.-B., Rodés-Cabau, J., Osten, M., Horlick, E., Wendler, O., Dumont, E., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.924613 · Cited by 508
Levine, G. N., Gomes, A. S., Arai, A. E., Bluemke, D. A., Flamm, S. D., Kanal, E., Manning, W. J., Martin, E. T., Smith, J. M., Wilke, N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187256 · Cited by 489
Lurz, P., Coats, L., Khambadkone, S., Nordmeyer, J., Boudjemline, Y., Schievano, S., Muthurangu, V., Lee, T. Y., Parenzan, G., Derrick, G., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.735779 · Cited by 481
Self-citationZahn, E. M., Hellenbrand, W. E., Lock, J. E., & McElhinney, D. B. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.034 · Cited by 322
Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients
Eicken, A., Ewert, P., Hager, A., Peters, B., Fratz, S., Kuehne, T., Busch, R., Hess, J., & Berger, F. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq520 · Cited by 296
Indications and Timing of Pulmonary Valve Replacement After Tetralogy of Fallot Repair
Geva, T. (2006) · Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2006.02.009 · Cited by 275
Wald, R. M., Haber, I., Wald, R., Valente, A. M., Powell, A. J., & Geva, T. (2009) · Circulation · doi:10.1161/circulationaha.108.816546 · Cited by 265
Kenny, D., Hijazi, Z. M., Kar, S., Rhodes, J., Mullen, M., Makkar, R., Shirali, G., Fogel, M., Fahey, J., Heitschmidt, M. G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.07.040 · Cited by 263
Bhatt, A. B., Foster, E., Kuehl, K., Alpert, J., Brabeck, S., Crumb, S., Davidson, W. R., Earing, M. G., Ghoshhajra, B. B., Karamlou, T., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000204 · Cited by 253
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Tetralogy of Fallot: From fetus to adult
Shinebourne, E. A., Babu-Narayan, S. V., & Carvalho, J. S. (2006) · Heart · doi:10.1136/hrt.2005.061143 · Cited by 134
“Recently Bonhoeffer’s group introduced transcatheter pulmonary valve implantation, using a stent-mounted bovine jugular venous valve.”
BackgroundGerling, C., Rukosujew, A., Kehl, H.-G., Tjan, T. D. T., Hoffmeier, A., Vogt, J., Scheld, H.-H., & Krasemann, T. (2009) · Herz Kardiovaskuläre Erkrankungen · doi:10.1007/s00059-009-3169-x · Cited by 15
Metadata
- Authors
- Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., Pellerin, D., Deanfield, J., & Bonhoeffer, P.
- Venue
- Circulation
- Published
- 2005-08-23
- Volume
- 112
- Issue
- 8
- Pages
- 1189-1197
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2110917599
- Cited by
- 459
- References
- 25
- FWCI
- 21.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.