The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Contrast-Enhanced Multidetector Computed Tomography Viability Imaging After Myocardial Infarction: Characterization of Myocyte Death, Microvascular Obstruction, and Chronic Scar
Open accessAbstract
Background— The ability to distinguish dysfunctional but viable myocardium from nonviable tissue has important prognostic implications after myocardial infarction. The purpose of this study was to validate the accuracy of contrast-enhanced multidetector computed tomography (MDCT) for quantifying myocardial necrosis, microvascular obstruction, and chronic scar after occlusion/reperfusion myocardial infarction. Methods and Results— Ten dogs and 7 pigs underwent balloon occlusion of the left anterior descending coronary artery (LAD) followed by reperfusion. Contrast-enhanced (Visipaque, 150 mL, 325 mg/mL) MDCT (0.5 mm × 32 slice) was performed before occlusion and 90 minutes (canine) or 8 weeks (porcine) after reperfusion. MDCT images were analyzed to define infarct size/extent and microvascular obstruction and compared with postmortem myocardial staining (triphenyltetrazolium chloride) and microsphere blood flow measurements. Acute and chronic infarcts by MDCT were characterized by hyperenhancement, whereas regions of microvascular obstruction were characterized by hypoenhancement. MDCT infarct volume compared well with triphenyltetrazolium chloride staining (acute infarcts 21.1±7.2% versus 20.4±7.4%, mean difference 0.7%; chronic infarcts 4.15±1.93% versus 4.92±2.06%, mean difference −0.76%) and accurately reflected morphology and the transmural extent of injury in all animals. Peak hyperenhancement of infarcted regions occurred ≈5 minutes after contrast injection. MDCT-derived regions of microvascular obstruction were also identified accurately in acute studies and correlated with reduced flow regions as measured by microsphere blood flow. Conclusions— The spatial extent of acute and healed myocardial infarction can be determined and quantified accurately with contrast-enhanced MDCT. This feature, combined with existing high-resolution MDCT coronary angiography, may have important implications for the comprehensive assessment of cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,602
Ito, H., Tomooka, T., Sakai, N., Yu, H., Higashino, Y., Fujii, K., Masuyama, T., Kitabatake, A., & Minamino, T. (1992) · Circulation · doi:10.1161/01.cir.85.5.1699 · Cited by 1,054
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Results of coronary artery surgery in patients with poor left ventricular function (CASS).
Alderman, E. L., Fisher, L. D., Litwin, P., Kaiser, G. C., Myers, W. O., Maynard, C., Levine, F., & Schloss, M. (1983) · Circulation · doi:10.1161/01.cir.68.4.785 · Cited by 804
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Lima, J. A. C., Judd, R. M., Bazille, A., Schulman, S. P., Atalar, E., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.5.1117 · Cited by 474
Self-citationJudd, R. M., Lugo-Olivieri, C. H., Arai, M., Kondo, T., Croisille, P., Lima, J. A. C., Mohan, V., Becker, L. C., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1902 · Cited by 463
Self-citationPagley, P. R., Beller, G. A., Watson, D. D., Gimple, L. W., & Ragosta, M. (1997) · Circulation · doi:10.1161/01.cir.96.3.793 · Cited by 392
Wu, K. C., Kim, R. J., Bluemke, D. A., Rochitte, C. E., Zerhouni, E. A., Becker, L. C., & Lima, J. A. C. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00429-x · Cited by 321
Self-citationOshinski, J. N., Yang, Z., Jones, J. R., Mata, J. F., & French, B. A. (2001) · Circulation · doi:10.1161/hc4801.100351 · Cited by 251
Stable labeled microspheres to measure perfusion: validation of a neutron activation assay technique
Reinhardt, C. P., Dalhberg, S., Tries, M. A., Marcel, R., & Leppo, J. A. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.1.h108 · Cited by 134
Noninvasive Imaging of Myocardial Viability: Current Techniques and Future Developments
Wu, K. C., & Lima, J. A. C. (2003) · Circulation Research · doi:10.1161/01.res.0000103863.40055.e8 · Cited by 116
Self-citationSaeed, M., Bremerich, J., Wendland, M. F., Wyttenbach, R., Weinmann, H., & Higgins, C. B. (1999) · Radiology · doi:10.1148/radiology.213.1.r99se30247 · Cited by 116
Cited by
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citationLancellotti, P., Nkomo, V. T., Badano, L. P., Bergler, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.005 · Cited by 484
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler-Klein, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet123 · Cited by 353
Buck, A. K., Nekolla, S., Ziegler, S., Beer, A., Krause, B. J., Herrmann, K., Scheidhauer, K., Wester, H.-J., Rummeny, E. J., Schwaiger, M., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050195 · Cited by 282
Metadata
- Authors
- Lardo, A. C., Cordeiro, M. A. S., Silva, C., Amado, L. C., George, R. T., Saliaris, A. P., Schuleri, K. H., Fernandes, V. R., Zviman, M., Nazarian, S., Halperin, H. R., Wu, K. C., Hare, J. M., & Lima, J. A. C.
- Venue
- Circulation
- Published
- 2006-01-24
- Volume
- 113
- Issue
- 3
- Pages
- 394-404
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2169415812
- Cited by
- 383
- References
- 15
- FWCI
- 35.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.