The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Open accessAbstract
Background— Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. Methods and Results— The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81±6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6±0.2 to 1.6±0.4 cm 2 . There were no intraprocedural deaths. At follow-up of 75±55 days, 16 patients (89%) remained alive. Conclusions— This initial experience suggests that percutaneous transarterial aortic valve implantation is feasible in selected high-risk patients with satisfactory short-term outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Evaluation of aortic insufficiency by Doppler color flow mapping
Perry, G. J., Helmcke, F., Nanda, N. C., Byard, C., & Soto, B. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80254-1 · Cited by 882
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Otto, C. M., Mickel, M. C., Kennedy, J. W., Alderman, E. L., Bashore, T. M., Block, P. C., Brinker, J. A., Diver, D., Ferguson, J., & Holmes, D. R. (1994) · Circulation · doi:10.1161/01.cir.89.2.642 · Cited by 476
Cardiac Catheterization, Angiography, and Intervention
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-8-664_3 · Cited by 423
Balloon aortic valvuloplasty in adults: Failure of procedure to improve long-term survival
Lieberman, E. B., Bashore, T. M., Hermiller, J. B., Wilson, J. S., Pieper, K. S., Keeler, G. P., Pierce, C. H., Kisslo, K. B., Harrison, J. K., & Davidson, C. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00363-0 · Cited by 299
Grossman & Baim's Cardiac Catheterization, Angiography, and Intervention
Baim, D. S., & Grossman, W. (2013) · Cited by 262
Bonow, R. O., Carabello, B., de Leon, A. C., Edmunds, L. H., Fedderly, B. J., Freed, M. D., Gaasch, W. H., McKay, C. R., Nishimura, R. A., O’Gara, P. T., et al. (2000) · Indian Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/s12055-000-0010-9 · Cited by 246
Cited by
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationRecommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationWebb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Self-citationGrube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Carabello, B. A., & Paulus, W. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60211-7 · Cited by 818
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Self-citationVahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Piazza, N., de Jaegere, P., Schultz, C., Becker, A. E., Serruys, P. W., & Anderson, R. H. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.780858 · Cited by 651
Ribeiro, H. B., Webb, J. G., Makkar, R. R., Cohen, M. G., Kapadia, S. R., Kodali, S., Tamburino, C., Barbanti, M., Chakravarty, T., Jilaihawi, H., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.040 · Cited by 647
Self-citationTranscatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes
Webb, J. G., Altwegg, L., Boone, R. H., Cheung, A., Ye, J., Lichtenstein, S., Lee, M., Masson, J. B., Thompson, C., Moss, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.837807 · Cited by 589
Self-citationTransfemoral Aortic Valve Implantation
Hayashida, K., Lefèvre, T., Chevalier, B., Hovasse, T., Romano, M., Garot, P., Mylotte, D., Uribe, J., Farge, A., Donzeau-Gouge, P., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.03.019 · Cited by 564
Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience
Lichtenstein, S. V., Cheung, A., Ye, J., Thompson, C. R., Carere, R. G., Pasupati, S., & Webb, J. G. (2006) · Circulation · doi:10.1161/circulationaha.106.632927 · Cited by 561
Self-citationEltchaninoff, H., Prat, A., Gilard, M., Leguerrier, A., Blanchard, D., Fournial, G., Iung, B., Donzeau-Gouge, P., Tribouilloy, C., Debrux, J.-L., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq261 · Cited by 554
Zamorano, J. L., Badano, L. P., Bruce, C., Chan, K.-L., Gonçalves, A., Hahn, R. T., Keane, M. G., La Canna, G., Monaghan, M. J., Nihoyannopoulos, P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.07.003 · Cited by 532
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Colombo, A., Lange, R., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.001545 · Cited by 524
Kahlert, P., Knipp, S. C., Schlamann, M., Thielmann, M., Al-Rashid, F., Weber, M., Johansson, U., Wendt, D., Jakob, H. G., Forsting, M., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.855866 · Cited by 521
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Self-citationBagur, R., Webb, J. G., Nietlispach, F., Dumont, E., De Larochelliere, R., Doyle, D., Masson, J.-B., Gutierrez, M. J., Clavel, M.-A., Bertrand, O. F., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp552 · Cited by 477
Self-citationRibeiro, H. B., Rodés-Cabau, J., Blanke, P., Leipsic, J., Kwan Park, J., Bapat, V., Makkar, R., Simonato, M., Barbanti, M., Schofer, J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx455 · Cited by 430
Self-citationMultimodal Assessment of the Aortic Annulus Diameter
Messika-Zeitoun, D., Serfaty, J.-M., Brochet, E., Ducrocq, G., Lepage, L., Detaint, D., Hyafil, F., Himbert, D., Pasi, N., Laissy, J.-P., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.063 · Cited by 422
Dewey, T. M., Brown, D., Ryan, W. H., Herbert, M. A., Prince, S. L., & Mack, M. J. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.09.011 · Cited by 405
Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
Détaint, D., Lepage, L., Himbert, D., Brochet, E., Messika-Zeitoun, D., Iung, B., & Vahanian, A. (2009) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2009.07.003 · Cited by 386
One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
Lefevre, T., Kappetein, A. P., Wolner, E., Nataf, P., Thomas, M., Schachinger, V., De Bruyne, B., Eltchaninoff, H., Thielmann, M., Himbert, D., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq427 · Cited by 376
Grube, E., Buellesfeld, L., Mueller, R., Sauren, B., Zickmann, B., Nair, D., Beucher, H., Felderhoff, T., Iversen, S., & Gerckens, U. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.819839 · Cited by 352
The German Aortic Valve Registry (GARY): in-hospital outcome
Hamm, C. W., Mollmann, H., Holzhey, D., Beckmann, A., Veit, C., Figulla, H.-R., Cremer, J., Kuck, K.-H., Lange, R., Zahn, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht381 · Cited by 328
Coronary Obstruction Following Transcatheter Aortic Valve Implantation
Ribeiro, H. B., Nombela-Franco, L., Urena, M., Mok, M., Pasian, S., Doyle, D., DeLarochellière, R., Côté, M., Laflamme, L., DeLarochellière, H., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.11.014 · Cited by 337
Cerebral Embolization During Transcatheter Aortic Valve Implantation: A Transcranial Doppler Study
Kahlert, P., Al-Rashid, F., Döttger, P., Mori, K., Plicht, B., Wendt, D., Bergmann, L., Kottenberg, E., Schlamann, M., Mummel, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.092544 · Cited by 335
Zamorano, J. L., Badano, L. P., Bruce, C., Chan, K.-L., Goncalves, A., Hahn, R. T., Keane, M. G., La Canna, G., Monaghan, M. J., Nihoyannopoulos, P., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr259 · Cited by 320
Multicenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve
Webb, J., Gerosa, G., Lefèvre, T., Leipsic, J., Spence, M., Thomas, M., Thielmann, M., Treede, H., Wendler, O., & Walther, T. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.026 · Cited by 313
Self-citationTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Vahanian, A., Alfieri, O. R., Al-Attar, N., Antunes, M. J., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.04.039 · Cited by 305
Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves
Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., Gick, M., Buettner, H.-J., Leipsic, J., Langer, M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv526 · Cited by 292
Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
Leipsic, J., Gurvitch, R., LaBounty, T. M., Min, J. K., Wood, D., Johnson, M., Ajlan, A. M., Wijesinghe, N., & Webb, J. G. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.014 · Cited by 287
Self-citationHimbert, D., Descoutures, F., Al-Attar, N., Iung, B., Ducrocq, G., Détaint, D., Brochet, E., Messika-Zeitoun, D., Francis, F., Ibrahim, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.032 · Cited by 280
Svensson, L. G., Dewey, T., Kapadia, S., Roselli, E. E., Stewart, A., Williams, M., Anderson, W. N., Brown, D., Leon, M., Lytle, B., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.04.049 · Cited by 278
Kenny, D., Hijazi, Z. M., Kar, S., Rhodes, J., Mullen, M., Makkar, R., Shirali, G., Fogel, M., Fahey, J., Heitschmidt, M. G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.07.040 · Cited by 263
Gurvitch, R., Wood, D. A., Tay, E. L., Leipsic, J., Ye, J., Lichtenstein, S. V., Thompson, C. R., Carere, R. G., Wijesinghe, N., Nietlispach, F., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.948877 · Cited by 258
Self-citationComprehensive Analysis of Mortality Among Patients Undergoing TAVR
Svensson, L. G., Blackstone, E. H., Rajeswaran, J., Brozzi, N., Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Tuzcu, E. M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.08.1666 · Cited by 88
Self-citation
Metadata
- Authors
- Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S.
- Venue
- Circulation
- Published
- 2006-02-14
- Volume
- 113
- Issue
- 6
- Pages
- 842-850
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2148154533
- Cited by
- 900
- References
- 23
- FWCI
- 55.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.