Human Semilunar Cardiac Valve Remodeling by Activated Cells From Fetus to Adult: Implications for Postnatal Adaptation, Pathology, and Tissue Engineering
Abstract
Background— The evolution of cell phenotypes and matrix architecture in cardiac valves during fetal maturation and postnatal adaptation through senescence remains unexplored. Methods and Results— We hypothesized that valvular interstitial (VIC) and endothelial cell (VEC) phenotypes, critical for maintaining valve function, change throughout life in response to environmental stimuli. We performed quantitative histological assessment of 91 human semilunar valves obtained from fetuses at 14 to 19 and 20 to 39 weeks’ gestation; neonates minutes to 30 days old; children aged 2 to 16 years; and adults. A trilaminar architecture appeared by 36 weeks of gestation but remained rudimentary compared with that of adult valves. VECs expressed an activated phenotype throughout fetal development. VIC density, proliferation, and apoptosis were significantly higher in fetal than adult valves. Pulmonary and aortic fetal VICs showed an activated myofibroblast-like phenotype (α-actin expression), abundant embryonic myosin, and matrix metalloproteinase-collagenases, which indicates an immature/activated phenotype engaged in matrix remodeling versus a quiescent fibroblast-like phenotype in adults. At birth, the abrupt change from fetal to neonatal circulation was associated with a greater number of α-actin–positive VICs in neonatal aortic versus pulmonary valves. Collagen content increased from early to late fetal stages but was subsequently unchanged, whereas elastin significantly increased postnatally. Collagen fiber color analysis revealed a progressive temporal decrease in thin fibers and a corresponding increase in thick fibers. Additionally, collagen fibers were more aligned in adult than fetal valves. Conclusions— Fetal valves possess a dynamic/adaptive structure and contain cells with an activated/immature phenotype. During postnatal life, activated cells gradually become quiescent, whereas collagen matures, which suggests a progressive, environmentally mediated adaptation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robbins and Cotran Pathologic Basis of Disease
Hoda, S. A., & Hoda, R. S. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa163 · Cited by 3,365
Molecular Regulation of Atrioventricular Valvuloseptal Morphogenesis
Eisenberg, L. M., & Markwald, R. R. (1995) · Circulation Research · doi:10.1161/01.res.77.1.1 · Cited by 648
Rabkin, E., Aikawa, M., Stone, J. R., Fukumoto, Y., Libby, P., & Schoen, F. J. (2001) · Circulation · doi:10.1161/hc4601.099489 · Cited by 620
Self-citationAikawa, M., Rabkin, E., Okada, Y., Voglic, S. J., Clinton, S. K., Brinckerhoff, C. E., Sukhova, G. K., & Libby, P. (1998) · Circulation · doi:10.1161/01.cir.97.24.2433 · Cited by 555
Self-citationWhittaker, P., Kloner, R. A., Boughner, D. R., & Pickering, J. G. (1994) · Basic Research in Cardiology · doi:10.1007/bf00788278 · Cited by 496
Self-citationRich, L. F., & Whittaker, P. (2005) · Cited by 363
Self-citationDynamic and reversible changes of interstitial cell phenotype during remodeling of cardiac valves.
Aikawa, E. R., Farber, M., Aikawa, M., & Schöen, F. J. (2004) · PubMed · Cited by 354
Self-citationAikawa, M., Sivam, P. N., Kuro-o, M., Kimura, K., Nakahara, K., Takewaki, S., Ueda, M., Yamaguchi, H., Yazaki, Y., & Periasamy, M. (1993) · Circulation Research · doi:10.1161/01.res.73.6.1000 · Cited by 339
Self-citationNew polarized light microscope with precision universal compensator
OLDENBOURG, R., & MEI, G. (1995) · Journal of Microscopy · doi:10.1111/j.1365-2818.1995.tb03669.x · Cited by 326
Butcher, J. T., Penrod, A. M., García, A. J., & Nerem, R. M. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000130462.50769.5a · Cited by 295
The Myofibroblast: A Quarter Century After Its Discovery
Schürch, W., Seemayer, T. A., & Gabbiani, G. (1998) · The American Journal of Surgical Pathology · doi:10.1097/00000478-199802000-00001 · Cited by 294
Development of heart valve leaflets and supporting apparatus in chicken and mouse embryos
Lincoln, J., Alfieri, C. M., & Yutzey, K. E. (2004) · Developmental Dynamics · doi:10.1002/dvdy.20051 · Cited by 271
Deguchi, J.-O., Aikawa, E., Libby, P., Vachon, J. R., Inada, M., Krane, S. M., Whittaker, P., & Aikawa, M. (2005) · Circulation · doi:10.1161/circulationaha.105.562041 · Cited by 224
Self-citationSchroeder, J. A., Jackson, L. F., Lee, D. C., & Camenisch, T. D. (2003) · Journal of Molecular Medicine · doi:10.1007/s00109-003-0456-5 · Cited by 207
Cardiovascular tissue engineering
Rabkin, E., & Schoen, F. J. (2002) · Cardiovascular Pathology · doi:10.1016/s1054-8807(02)00130-8 · Cited by 200
Self-citationMitchell, R. N., Jonas, R. A., & Schoen, F. J. (1998) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70450-7 · Cited by 183
Self-citationSchöen, F. J. (1997) · PubMed · Cited by 176
Poelmann, R. E., Mikawa, T., & Gittenberger-De Groot, A. C. (1998) · Developmental Dynamics · doi:10.1002/(sici)1097-0177(199807)212:3<373::aid-aja5>3.0.co;2-e · Cited by 172
Clinical pulmonary autograft valves: Pathologic evidence of adaptive remodeling in the aortic site
Rabkin-Aikawa, E., Aikawa, M., Farber, M., Kratz, J. R., Garcia-Cardena, G., Kouchoukos, N. T., Mitchell, M. B., Jonas, R. A., & Schoen, F. J. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.04.016 · Cited by 169
Self-citationApoptosis During Cardiovascular Development
Fisher, S. A., Langille, B. L., & Srivastava, D. (2000) · Circulation Research · doi:10.1161/01.res.87.10.856 · Cited by 158
The Human Cardiovascular System. Facts and Concepts.
Fry, C. H. (1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-6-879_5 · Cited by 155
Intracardiac pressures in the human fetus
Johnson, P., Maxwell, D. J., Tynan, M. J., & Allan, L. D. (2000) · Heart · doi:10.1136/heart.84.1.59 · Cited by 153
Ghaisas, N., Foley, J. B., O'Briain, D. S., Crean, P., Kelleher, D., & Walsh, M. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00998-0 · Cited by 143
Aikawa, E. R., Hoerstrup, S. P., Aikawa, M., Mayer, J. E., & Schöen, F. J. (2002) · PubMed · Cited by 139
Self-citationAïkawa, E., Mayer, J. E., & Schöen, F. J. (2005) · Advances in biochemical engineering, biotechnology · doi:10.1007/b100003 · Cited by 128
The development of the semilunar valves in the human heart.
Maron, B. J., & Gm, H. (1974) · PubMed · Cited by 119
Whittaker, P., & Canham, P. B. (1991) · Matrix · doi:10.1016/s0934-8832(11)80227-1 · Cited by 96
Self-citationDevelopment of mouse semilunar valves
Hurlé, J. M., Colv�e, E., & Blanco, A. M. (1980) · Anatomy and Embryology · doi:10.1007/bf00315651 · Cited by 64
Mol, A., Bouten, C. V. C., Baaijens, F. F., Zünd, G., Turina, M. I., & Hoerstrup, S. P. (2004) · PubMed · Cited by 61
Batschelet, E., Hillman, D., Smolensky, M. H., & Franz Halberg, A. (1973) · PubMed · Cited by 40
Romańska, H., Ikonen, T. S., Bishop, A. E., Morris, R. E., & Polak, J. M. (2000) · The Journal of Pathology · doi:10.1002/(sici)1096-9896(200005)191:1<54::aid-path568>3.0.co;2-y · Cited by 28
Human pulmonary valve endothelial cells express functional adhesion molecules for leukocytes.
Dvorin, E. L., Jacobson, J. P., Roth, S. J., & Bischoff, J. E. (2003) · PubMed · Cited by 16
Cited by
Swirski, F. K., Libby, P., Aikawa, E., Alcaide, P., Luscinskas, F. W., Weissleder, R., & Pittet, M. J. (2007) · Journal of Clinical Investigation · doi:10.1172/jci29950 · Cited by 1,148
Self-citation3D Bioprinting of heterogeneous aortic valve conduits with alginate/gelatin hydrogels
Duan, B., Hockaday, L. A., Kang, K. H., & Butcher, J. T. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34420 · Cited by 1,002
Rajamannan, N. M., Evans, F. J., Aikawa, E., Grande-Allen, K. J., Demer, L. L., Heistad, D. D., Simmons, C. A., Masters, K. S., Mathieu, P., O'Brien, K. D., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.006767 · Cited by 842
Self-citationAikawa, E., Nahrendorf, M., Figueiredo, J.-L., Swirski, F. K., Shtatland, T., Kohler, R. H., Jaffer, F. A., Aikawa, M., & Weissleder, R. (2007) · Circulation · doi:10.1161/circulationaha.107.732867 · Cited by 698
Self-citationThe Emerging Role of Valve Interstitial Cell Phenotypes in Regulating Heart Valve Pathobiology
Liu, A. C., Joag, V. R., & Gotlieb, A. I. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.070251 · Cited by 632
Metadata
- Authors
- Aikawa, E., Whittaker, P., Farber, M., Mendelson, K., Padera, R. F., Aikawa, M., & Schoen, F. J.
- Venue
- Circulation
- Published
- 2006-03-14
- Volume
- 113
- Issue
- 10
- Pages
- 1344-1352
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2040321633
- Cited by
- 426
- References
- 32
- FWCI
- 12.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.