CoChat

Bioartificial Sinus Node Constructed via In Vivo Gene Transfer of an Engineered Pacemaker HCN Channel Reduces the Dependence on Electronic Pacemaker in a Sick-Sinus Syndrome Model

Tse, Hung-Fat, Xue, Tian, Lau, Chu-Pak, Siu, Chung-Wah, Wang, Kai, Zhang, Qing-Yong, Tomaselli, Gordon F., Akar, Fadi G., Li, Ronald A. · 2006 · Circulation
Cited by 155

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background— The normal cardiac rhythm originates in the sinoatrial (SA) node that anatomically resides in the right atrium. Malfunction of the SA node leads to various forms of arrhythmias that necessitate the implantation of electronic pacemakers. We hypothesized that overexpression of an engineered HCN construct via somatic gene transfer offers a flexible approach for fine-tuning cardiac pacing in vivo. Methods and Results— Using various electrophysiological and mapping techniques, we examined the effects of in situ focal expression of HCN1-ΔΔΔ, the S3-S4 linker of which has been shortened to favor channel opening, on impulse generation and conduction. Single left ventricular cardiomyocytes isolated from guinea pig hearts preinjected with the recombinant adenovirus Ad-CMV-GFP-IRES-HCN1-ΔΔΔ in vivo uniquely exhibited automaticity with a normal firing rate (237±12 bpm). High-resolution ex vivo optical mapping of Ad-CGI-HCN1-ΔΔΔ–injected Langendorff-perfused hearts revealed the generation of spontaneous action potentials from the transduced region in the left ventricle. To evaluate the efficacy of our approach for reliable atrial pacing, we generated a porcine model of sick-sinus syndrome by guided radiofrequency ablation of the native SA node, followed by implantation of a dual-chamber electronic pacemaker to prevent bradycardia-induced hemodynamic collapse. Interestingly, focal transduction of Ad-CGI-HCN1-ΔΔΔ in the left atrium of animals with sick-sinus syndrome reproducibly induced a stable, catecholamine-responsive in vivo “bioartificial node” that exhibited a physiological heart rate and was capable of reliably pacing the myocardium, substantially reducing electronic pacing. Conclusions— The results of the present study provide important functional and mechanistic insights into cardiac automaticity and have further refined an HCN gene–based therapy for correcting defects in cardiac impulse generation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.615385

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Tse, H.-F., Xue, T., Lau, C.-P., Siu, C.-W., Wang, K., Zhang, Q.-Y., Tomaselli, G. F., Akar, F. G., & Li, R. A.
Venue
Circulation
Published
2006-09-05
Volume
114
Issue
10
Pages
1000-1011
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2155944121
Cited by
155
References
4
FWCI
10.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.