Background— The extent of the peri-infarct zone by magnetic resonance imaging (MRI) has been related to all-cause mortality in patients with coronary artery disease. This relationship may result from arrhythmogenesis in the infarct border. However, the relationship between tissue heterogeneity in the infarct periphery and arrhythmic substrate has not been investigated. In the present study, we quantify myocardial infarct heterogeneity by contrast-enhanced MRI and relate it to an electrophysiological marker of arrhythmic substrate in patients with left ventricular (LV) systolic dysfunction undergoing prophylactic implantable cardioverter defibrillator placement. Methods and Results— Before implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death, 47 patients underwent cine and contrast-enhanced MRI to measure LV function, volumes, mass, and infarct size. A method for quantifying the heterogeneous infarct periphery and the denser infarct core is described. MRI indices were related to inducibility of sustained monomorphic ventricular tachycardia during electrophysiological or device testing. For the noninducible versus inducible patients, LV ejection fraction (30±10% versus 29±7%, P =0.79), LV end-diastolic volume (220±70 versus 228±57 mL, P =0.68), and infarct size by standard contrast-enhanced MRI definitions ( P =NS) were similar. Quantification of tissue heterogeneity at the infarct periphery was strongly associated with inducibility for monomorphic ventricular tachycardia (noninducible versus inducible: 13±9 versus 19±8 g, P =0.015) and was the single significant factor in a stepwise logistic regression. Conclusions— Tissue heterogeneity is present and quantifiable within human infarcts. More extensive tissue heterogeneity correlates with increased ventricular irritability by programmed electrical stimulation. These findings support the hypothesis that anatomic tissue heterogeneity increases susceptibility to ventricular arrhythmias in patients with prior myocardial infarction and LV dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Zipes, D. P., & Wellens, H. J. J. (1998) · Circulation · doi:10.1161/01.cir.98.21.2334 · Cited by 2,744
Cited by
Schulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097
Self-citationOakes, R. S., Badger, T. J., Kholmovski, E. G., Akoum, N., Burgon, N. S., Fish, E. N., Blauer, J. J. E., Rao, S. N., DiBella, E. V. R., Segerson, N. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.811877 · Cited by 1,123
Assessment of Myocardial Fibrosis With Cardiovascular Magnetic Resonance
Mewton, N., Liu, C. Y., Croisille, P., Bluemke, D., & Lima, J. A. C. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.013 · Cited by 984
Self-citationEHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Fishman, G. I., Chugh, S. S., DiMarco, J. P., Albert, C. M., Anderson, M. E., Bonow, R. O., Buxton, A. E., Chen, P.-S., Estes, M., Jouven, X., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976092 · Cited by 614
Metadata
- Authors
- Schmidt, A., Azevedo, C. F., Cheng, A., Gupta, S. N., Bluemke, D. A., Foo, T. K., Gerstenblith, G., Weiss, R. G., Marbán, E., Tomaselli, G. F., Lima, J. A. C., & Wu, K. C.
- Venue
- Circulation
- Published
- 2007-04-17
- Volume
- 115
- Issue
- 15
- Pages
- 2006-2014
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2118333950
- Cited by
- 823
- References
- 2
- FWCI
- 36.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Infarct Tissue Heterogeneity by Magnetic Resonance Imaging Identifies Enhanced Cardiac Arrhythmia Susceptibility in Patients With Left Ventricular Dysfunction. https://app.cochat.ai/papers/10.1161/circulationaha.106.653568
- The paper
- Schmidt, A., Azevedo, C. F., Cheng, A., Gupta, S. N., Bluemke, D. A., Foo, T. K., Gerstenblith, G., Weiss, R. G., Marbán, E., Tomaselli, G. F., Lima, J. A. C., & Wu, K. C. (2007). Infarct Tissue Heterogeneity by Magnetic Resonance Imaging Identifies Enhanced Cardiac Arrhythmia Susceptibility in Patients With Left Ventricular Dysfunction. Circulation. https://doi.org/10.1161/circulationaha.106.653568
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.