Incidence and Predictors of Drug-Eluting Stent Thrombosis During and After Discontinuation of Thienopyridine Treatment
Open accessAbstract
Background— The need for prolonged aspirin and thienopyridine therapy and the risk of stent thrombosis (ST) remain as drawbacks associated with drug-eluting stents. Methods and Results— A prospective observational cohort study was conducted between June 2002 and January 2004 on 3021 patients consecutively and successfully treated in 5389 lesions with drug-eluting stents. Detailed patient information was collected on antiplatelet therapy. We analyzed the incidence of ST throughout the 18-month follow-up period and its relationship with thienopyridine therapy. ST occurred in 58 patients (1.9%) at 18 months. Forty-two patients (1.4%) experienced the event within 6 months of stent implantation. Acute myocardial infarction (fatal or nonfatal) occurred in 46 patients (79%) and death in 23 patients (39%) with ST. The median interval from discontinuation of thienopyridine therapy to ST was 13.5 days (interquartile range 5.2 to 25.7 days) for the first 6 months and 90 days (interquartile range 30 to 365 days) between 6 and 18 months. On multivariable analysis, the strongest predictor for ST within 6 months of stenting was discontinuation of thienopyridine therapy (hazard ratio, 13.74; 95% CI, 4.04 to 46.68; P <0.001). Thienopyridine discontinuation after 6 months did not predict the occurrence of ST (hazard ratio, 0.94; 95% CI, 0.30 to 2.98; P =0.92). Conclusions— Discontinuation of thienopyridine therapy was the major determinant of ST within the first 6 months, but insufficient information is available to determine whether there is benefit in continuing a thienopyridine beyond 6 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Antman, E., Bassand, J.-P., Klein, W., Ohman, M., Lopez Sendon, J. L., Rydén, L., Simoons, M., & Tendera, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00804-4 · Cited by 4,821
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Steinhubl, S. R., Berger, P. B., Mann III, J. T., Fry, E. T. A., DeLago, A., Wilmer, C., Topol, E. J., & for the CREDO Investigators (2002) · JAMA · doi:10.1001/jama.288.19.2411 · Cited by 3,078
Mehta, S. R., Yusuf, S., Peters, R. J., Bertrand, M. E., Lewis, B. S., Natarajan, M. K., Malmberg, K., Rupprecht, H.-J., Zhao, F., Chrolavicius, S., et al. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05701-4 · Cited by 2,809
Mehta, S. R., Yusuf, S., & Peters, R. J. G. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)00559-7 · Cited by 2,578
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Medication Adherence: WHO Cares?
Brown, M. T., & Bussell, J. K. (2011) · Mayo Clinic Proceedings · doi:10.4065/mcp.2010.0575 · Cited by 1,928
“001).(43) In a study of 500 drug-eluting stent recipients, 13.”
BackgroundLanas, A., & Chan, F. K. L. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32404-7 · Cited by 984
Palmerini, T., Biondi-Zoccai, G., Riva, D. D., Stettler, C., Sangiorgi, D., D'Ascenzo, F., Kimura, T., Briguori, C., Sabatè, M., Kim, H.-S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60324-9 · Cited by 959
Self-citationEverolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
Predictors of Coronary Stent Thrombosis
van Werkum, J. W., Heestermans, A. A., Zomer, A. C., Kelder, J. C., Suttorp, M.-J., Rensing, B. J., Koolen, J. J., Brueren, B. R. G., Dambrink, J.-H. E., Hautvast, R. W., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.055 · Cited by 700
Valgimigli, M., Campo, G., Monti, M., Vranckx, P., Percoco, G., Tumscitz, C., Castriota, F., Colombo, F., Tebaldi, M., Fucà, G., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.071589 · Cited by 672
Sibbing, D., Braun, S., Morath, T., Mehilli, J., Vogt, W., Schömig, A., Kastrati, A., & von Beckerath, N. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.11.030 · Cited by 651
Mehran, R., Baber, U., Steg, P. G., Ariti, C., Weisz, G., Witzenbichler, B., Henry, T. D., Kini, A. S., Stuckey, T., Cohen, D. J., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61720-1 · Cited by 616
Self-citationGwon, H.-C., Hahn, J.-Y., Park, K. W., Song, Y. B., Chae, I.-H., Lim, D.-S., Han, K.-R., Choi, J.-H., Choi, S.-H., Kang, H.-J., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.059022 · Cited by 614
Feres, F. (2013) · JAMA · doi:10.1001/jama.2013.282183 · Cited by 589
Duration of Dual Antiplatelet Therapy after Implantation of Drug-Eluting Stents
Park, S.-J., Park, D.-W., Kim, Y.-H., Kang, S.-J., Lee, S.-W., Lee, C. W., Han, K.-H., Park, S.-W., Yun, S.-C., Lee, S.-G., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001266 · Cited by 511
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Incidence and Correlates of Drug-Eluting Stent Thrombosis in Routine Clinical Practice
Wenaweser, P., Daemen, J., Zwahlen, M., van Domburg, R., Jüni, P., Vaina, S., Hellige, G., Tsuchida, K., Morger, C., Boersma, E., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.006 · Cited by 481
Colombo, A., Chieffo, A., Frasheri, A., Garbo, R., Masotti-Centol, M., Salvatella, N., Oteo Dominguez, J. F., Steffanon, L., Tarantini, G., Presbitero, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.008 · Cited by 430
Self-citationPrice, M. J., Angiolillo, D. J., Teirstein, P. S., Lillie, E., Manoukian, S. V., Berger, P. B., Tanguay, J.-F., Cannon, C. P., & Topol, E. J. (2011) · Circulation · doi:10.1161/circulationaha.111.029165 · Cited by 396
Holmes, D. R., Kereiakes, D. J., Garg, S., Serruys, P. W., Dehmer, G. J., Ellis, S. G., Williams, D. O., Kimura, T., & Moliterno, D. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.016 · Cited by 367
Antiplatelet Therapy and Stent Thrombosis After Sirolimus-Eluting Stent Implantation
Kimura, T., Morimoto, T., Nakagawa, Y., Tamura, T., Kadota, K., Yasumoto, H., Nishikawa, H., Hiasa, Y., Muramatsu, T., Meguro, T., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.808311 · Cited by 358
Duration of Dual Antiplatelet Therapy After Drug-Eluting Stent Implantation
Giustino, G., Baber, U., Sartori, S., Mehran, R., Mastoris, I., Kini, A. S., Sharma, S. K., Pocock, S. J., & Dangas, G. D. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.01.039 · Cited by 344
Collet, J.-P., Silvain, J., Barthélémy, O., Rangé, G., Cayla, G., Van Belle, E., Cuisset, T., Elhadad, S., Schiele, F., Lhoest, N., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60612-7 · Cited by 303
Khonsari, S., Subramanian, P., Chinna, K., Latif, L. A., Ling, L. W., & Gholami, O. (2015) · European Journal of Cardiovascular Nursing · doi:10.1177/1474515114521910 · Cited by 127
Quilici, J., Fugon, L., Beguin, S., Morange, P. E., Bonnet, J.-L., Alessi, M.-C., Carrieri, P., & Cuisset, T. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.252 · Cited by 68
“Aspirin resistance [2] or non-adherence [3,4] has been identified as important risk factor for recurrent ischemic events.”
Background
Metadata
- Authors
- Airoldi, F., Colombo, A., Morici, N., Latib, A., Cosgrave, J., Buellesfeld, L., Bonizzoni, E., Carlino, M., Gerckens, U., Godino, C., Melzi, G., Michev, I., Montorfano, M., Sangiorgi, G. M., Qasim, A., Chieffo, A., Briguori, C., & Grube, E.
- Venue
- Circulation
- Published
- 2007-08-14
- Volume
- 116
- Issue
- 7
- Pages
- 745-754
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1980915088
- Cited by
- 455
- References
- 25
- FWCI
- 32.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.