CoChat

Inadequate Blood Glucose Control Is Associated With In-Hospital Mortality and Morbidity in Diabetic and Nondiabetic Patients Undergoing Cardiac Surgery

Open access
Ascione, R., Rogers, C.A., Rajakaruna, C., Angelini, G.D. · 2008 · Circulation
Cited by 140

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background— Derangement of glucose metabolism after surgery is not specific to patients with diabetes mellitus. We investigated the effect of different degrees of blood glucose control (BGC) on clinical outcomes after cardiac surgery. Methods and Results— We analyzed 8727 adults operated on between April 1996 and March 2004. The highest blood glucose level recorded over the first 60 hours postoperatively was used to classify patients as having good (<200 mg/dL), moderate (200 to 250 mg/dL), or poor (>250 mg/dL) BGC; 7547 patients (85%) had good, 905 (10%) had moderate, and 365 (4%) had poor BGC. Patients with inadequate BGC were more likely to present with advanced New York Heart Association class, congestive heart failure, hypertension, renal dysfunction, and ejection fraction <50% ( P ≤0.001). We found that 52% of patients with poor, 31% with moderate, and 8% with good BGC had diabetes mellitus. Inadequate BGC, but not diabetes mellitus ( P =0.79), was associated with in-hospital mortality (good, 1.8%; moderate, 4.2%; poor, 9.6%; adjusted odds ratio: poor versus good BGC, 3.90 [95% confidence interval, 2.47 to 6.15]; moderate versus good BGC, 1.68 [95% confidence interval, 1.25 to 2.25]). Inadequate BGC also was associated with postoperative myocardial infarction (eg, odds ratio, poor versus good BGC: 2.73 [95% confidence interval, 1.74 to 4.26]) and with pulmonary and renal complications in patients without known diabetes mellitus (eg, odds ratio, poor versus good BGC: 2.27 [95% confidence interval, 1.65 to 3.12] and 2.82 [95% confidence interval, 1.54 to 5.14] respectively). Conclusions— More than 50% of patients with moderate to poor BGC after cardiac surgery were not previously identified as diabetic. Inadequate postoperative BGC is a predictor of in-hospital mortality and morbidity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.706416

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 140

Metadata

Authors
Ascione, R., Rogers, C. A., Rajakaruna, C., & Angelini, G. D.
Venue
Circulation
Published
2008-07-08
Volume
118
Issue
2
Pages
113-123
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2045241567
Cited by
140
References
3
FWCI
6.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inadequate Blood Glucose Control Is Associated With In-Hospital Mortality and Morbidity in Diabetic and Nondiabetic Patients Undergoing Cardiac Surgery. https://app.cochat.ai/papers/10.1161/circulationaha.107.706416
The paper
Ascione, R., Rogers, C. A., Rajakaruna, C., & Angelini, G. D. (2008). Inadequate Blood Glucose Control Is Associated With In-Hospital Mortality and Morbidity in Diabetic and Nondiabetic Patients Undergoing Cardiac Surgery. Circulation. https://doi.org/10.1161/circulationaha.107.706416

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.