CoChat

Embolic Protection and Platelet Inhibition During Renal Artery Stenting

Cooper, Christopher J., Haller, Steven T., Colyer, William, Steffes, Michael, Burket, Mark W., Thomas, William J., Safian, Robert, Reddy, Bhagat, Brewster, Pamela, Ankenbrandt, Mary Ann, Virmani, Renu, Dippel, Eric, Rocha-Singh, Krishna, Murphy, Timothy P., Kennedy, David J., Shapiro, Joseph I., D'Agostino, Ralph D., Pencina, Michael J., Khuder, Sadik · 2008 · Circulation
Cited by 173

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Background— Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. Methods and Results— One hundred patients undergoing renal artery stenting at 7 centers were randomly assigned to an open-label embolic protection device, Angioguard, or double-blind use of a platelet glycoprotein IIb/IIIa inhibitor, abciximab, in a 2×2 factorial design. The main effects of treatments and their interaction were assessed on percentage change in Modification in Diet in Renal Disease–derived glomerular filtration rate from baseline to 1 month using centrally analyzed creatinine. Filter devices were analyzed for the presence of platelet-rich thrombus. With stenting alone, stenting and embolic protection, and stenting with abciximab alone, glomerular filtration rate declined ( P <0.05), but with combination therapy, it did not decline and was superior to the other allocations in the 2×2 design ( P <0.01). The main effects of treatment demonstrated no overall improvement in glomerular filtration rate; although abciximab was superior to placebo (0±27% versus −10±20%; P <0.05), embolic protection was not (−1±28% versus −10±20%; P =0.08). An interaction was observed between abciximab and embolic protection ( P <0.05), favoring combination treatment. Abciximab reduced the occurrence of platelet-rich emboli in the filters from 42% to 7% ( P <0.01). Conclusions— Renal artery stenting alone, stenting with embolic protection, and stenting with abciximab were associated with a decline in glomerular filtration rate. An unanticipated interaction between Angioguard and abciximab was seen, with combination therapy better than no treatment or either treatment alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.730259

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 173

Metadata

Authors
Cooper, C. J., Haller, S. T., Colyer, W., Steffes, M., Burket, M. W., Thomas, W. J., Safian, R., Reddy, B., Brewster, P., Ankenbrandt, M. A., Virmani, R., Dippel, E., Rocha-Singh, K., Murphy, T. P., Kennedy, D. J., Shapiro, J. I., D'Agostino, R. D., Pencina, M. J., & Khuder, S.
Venue
Circulation
Published
2008-05-27
Volume
117
Issue
21
Pages
2752-2760
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1964147727
Cited by
173
References
25
FWCI
21.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Embolic Protection and Platelet Inhibition During Renal Artery Stenting. https://app.cochat.ai/papers/10.1161/circulationaha.107.730259
The paper
Cooper, C. J., Haller, S. T., Colyer, W., Steffes, M., Burket, M. W., Thomas, W. J., Safian, R., Reddy, B., Brewster, P., Ankenbrandt, M. A., Virmani, R., Dippel, E., Rocha-Singh, K., Murphy, T. P., Kennedy, D. J., Shapiro, J. I., D'Agostino, R. D., Pencina, M. J., & Khuder, S. (2008). Embolic Protection and Platelet Inhibition During Renal Artery Stenting. Circulation. https://doi.org/10.1161/circulationaha.107.730259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.