Embolic Protection and Platelet Inhibition During Renal Artery Stenting
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background— Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. Methods and Results— One hundred patients undergoing renal artery stenting at 7 centers were randomly assigned to an open-label embolic protection device, Angioguard, or double-blind use of a platelet glycoprotein IIb/IIIa inhibitor, abciximab, in a 2×2 factorial design. The main effects of treatments and their interaction were assessed on percentage change in Modification in Diet in Renal Disease–derived glomerular filtration rate from baseline to 1 month using centrally analyzed creatinine. Filter devices were analyzed for the presence of platelet-rich thrombus. With stenting alone, stenting and embolic protection, and stenting with abciximab alone, glomerular filtration rate declined ( P <0.05), but with combination therapy, it did not decline and was superior to the other allocations in the 2×2 design ( P <0.01). The main effects of treatment demonstrated no overall improvement in glomerular filtration rate; although abciximab was superior to placebo (0±27% versus −10±20%; P <0.05), embolic protection was not (−1±28% versus −10±20%; P =0.08). An interaction was observed between abciximab and embolic protection ( P <0.05), favoring combination treatment. Abciximab reduced the occurrence of platelet-rich emboli in the filters from 42% to 7% ( P <0.01). Conclusions— Renal artery stenting alone, stenting with embolic protection, and stenting with abciximab were associated with a decline in glomerular filtration rate. An unanticipated interaction between Angioguard and abciximab was seen, with combination therapy better than no treatment or either treatment alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Linear Statistical Models
Ziegel, E. R., Neter, J., Wasserman, W., & Kutner, M. (1992) · Technometrics · doi:10.2307/1269588 · Cited by 9,907
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
STUDIES ON EXPERIMENTAL HYPERTENSION
Goldblatt, H., Lynch, J., Hanzal, R. F., & Summerville, W. W. (1934) · Journal of Experimental Medicine · doi:10.1084/jem.59.3.347 · Cited by 2,142
(1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362401 · Cited by 1,883
Safian, R. D., & Textor, S. C. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102083440607 · Cited by 1,068
Self-citationThe Effect of Balloon Angioplasty on Hypertension in Atherosclerotic Renal-Artery Stenosis
van Jaarsveld, B. C., Krijnen, P., Pieterman, H., Derkx, F. H. M., Deinum, J., Postma, C. T., Dees, A., Woittiez, A. J. J., Bartelink, A. K. M., Man in `t Veld, A. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200004063421403 · Cited by 897
van de Ven, P. J., Kaatee, R., Beutler, J. J., Beek, F. J., Woittiez, A.-J. J., Buskens, E., Koomans, H. A., & Mali, W. P. T. (1999) · The Lancet · doi:10.1016/s0140-6736(98)04432-8 · Cited by 583 · cited 1×
“Congestive heart failure 6 (21) 6 (27) 6 (25) 7 (28) 0.”
Prevalence of renovascular disease in the elderly: A population-based study
Hansen, K. J., Edwards, M. S., Craven, T. E., Cherr, G. S., Jackson, S. A., Appel, R. G., Burke, G. L., & Dean, R. H. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.127351 · Cited by 506
Applied Linear Statistical Models (3rd ed.).
Lorenz, F. O., Neter, J., Wasserman, W., & Kutner, M. H. (1992) · Journal of the American Statistical Association · doi:10.2307/2290239 · Cited by 478
Effect of renal-artery stenting on progression of renovascular renal failure
Harden, P., MacLeod, M., Rodger, R., Baxter, G., Connell, J., Dominiczak, A., Junor, B., Briggs, J., & Moss, J. (1997) · The Lancet · doi:10.1016/s0140-6736(96)10093-3 · Cited by 367
Dorros, G., Jaff, M., Mathiak, L., Dorros, I. I., Lowe, A., Murphy, K., & He, T. (1998) · Circulation · doi:10.1161/01.cir.98.7.642 · Cited by 361 · cited 2×
“Congestive heart failure 6 (21) 6 (27) 6 (25) 7 (28) 0.”
Effect of Renal-Artery Stenting on Progression of Renovascular Renal Failure
Harden, P. N., MacLeod, M. J., Rodger, R. S. C., Baxter, G. M., Connell, J. M. C., Dominiczak, A. F., Junor, B. J. R., Brigs, J. D., & Moss, J. G. (1999) · The Journal of Urology · doi:10.1097/00005392-199903000-00090 · Cited by 356
Cooper, C. J., Murphy, T. P., Matsumoto, A., Steffes, M., Cohen, D. J., Jaff, M., Kuntz, R., Jamerson, K., Reid, D., Rosenfield, K., et al. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.09.011 · Cited by 287
Self-citationEvaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System
Erlandsen, E. J., Randers, E., & Kristensen, J. H. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185940 · Cited by 258 · cited 1×
“N-acetylcysteine or sodium bicarbonate 5 (18) 3 (14) 1 (4) 3 (12) 0.”
Rocha-Singh, K., Jaff, M. R., & Rosenfield, K. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.11.073 · Cited by 167
Self-citationKennedy, D. J., Colyer, W. R., Brewster, P. S., Ankenbrandt, M., Burket, M. W., Nemeth, A. S., Khuder, S., Thomas, W. J., Shapiro, J. I., & Cooper, C. J. (2003) · American Journal of Kidney Diseases · doi:10.1016/j.ajkd.2003.06.004 · Cited by 114
Self-citationUehata, A., Matsuguchi, T., Bittl, J. A., Orav, E. J., Meredith, I. T., Anderson, T. J., Selwyn, A. P., Ganz, P., & Yeung, A. C. (1993) · Circulation · doi:10.1161/01.cir.88.4.1724 · Cited by 104 · cited 1×
“N-acetylcysteine or sodium bicarbonate 5 (18) 3 (14) 1 (4) 3 (12) 0.”
Protected Renal Stenting With the PercuSurge GuardWire Device:A Pilot Study
Henry, M., Klonaris, C., henry, I. P., Tzetanov, K., Borgne, E. L., Foliguet, B., & Hugel, M. (2001) · Journal of Endovascular Therapy · doi:10.1177/152660280100800301 · Cited by 89
Baboolal, K., Evans, C., & Moore, R. (1998) · American Journal of Kidney Diseases · doi:10.1053/ajkd.1998.v31.pm9631841 · Cited by 88
Distal embolic protection during renal artery angioplasty and stenting
Edwards, M. S., Craven, B. L., Stafford, J. M., Craven, T. E., Sauve, K. J., Ayerdi, J. A., Geary, R. L., & Hansen, K. J. (2006) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.03.022 · Cited by 69
Low-profile Stent System for Treatment of Atherosclerotic Renal Artery Stenosis: The GREAT Trial
Sapoval, M. R., Zähringer, M., Pattynama, P. M. T., Rabbia, C., Vignali, C., Maleux, G. A., Boyer, L., Szczerbo‐Trojanowska, M., Jaschke, W. R., Hafsahl, G., et al. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000171765.67665.d3 · Cited by 59
Diagnosis and evaluation of renovascular hypertension. Indications for therapy.
Pickering, T. G. (1991) · PubMed · Cited by 44
Hammoudeh, A. J., Chaaban, F., Watson, R. M., & Millman, A. E. (1996) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/(sici)1097-0304(199603)37:3<243::aid-ccd3>3.0.co;2-c · Cited by 31
Cited by
ESC Guidelines on the diagnosis and treatment of peripheral artery diseases
Endorsed by: the European Stroke Organisation (ESO), Authors/Task Force Members, Tendera, M., Aboyans, V., Bartelink, M.-L., Baumgartner, I., Clément, D., Collet, J.-P., Cremonesi, A., De Carlo, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr211 · Cited by 1,506
Nadim, M. K., Forni, L. G., Bihorac, A., Hobson, C., Koyner, J. L., Shaw, A., Arnaoutakis, G. J., Ding, X., Engelman, D. T., Gasparovic, H., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008834 · Cited by 340
Renovascular Hypertension and Ischemic Nephropathy
Textor, S. C., & Lerman, L. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2010.174 · Cited by 196
Raman, G., Adam, G. P., Halladay, C. W., Langberg, V. N., Azodo, I. A., & Balk, E. M. (2016) · Annals of Internal Medicine · doi:10.7326/m16-1053 · Cited by 81
Renal Artery Stenosis: Optimal Therapy and Indications for Revascularization
Patel, S. M., Li, J., & Parikh, S. A. (2015) · Current Cardiology Reports · doi:10.1007/s11886-015-0623-7 · Cited by 16
Metadata
- Authors
- Cooper, C. J., Haller, S. T., Colyer, W., Steffes, M., Burket, M. W., Thomas, W. J., Safian, R., Reddy, B., Brewster, P., Ankenbrandt, M. A., Virmani, R., Dippel, E., Rocha-Singh, K., Murphy, T. P., Kennedy, D. J., Shapiro, J. I., D'Agostino, R. D., Pencina, M. J., & Khuder, S.
- Venue
- Circulation
- Published
- 2008-05-27
- Volume
- 117
- Issue
- 21
- Pages
- 2752-2760
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1964147727
- Cited by
- 173
- References
- 25
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.