Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System

Erlandsen, E. J, Randers, E, Kristensen, J. H·1999·Scandinavian Journal of Clinical and Laboratory Investigation

Abstract

The Dade Behring N Latex Cystatin C assay, a particle-enhanced nephelometric immunoassay for measuring serum cystatin C, was evaluated on the Dade Behring Nephelometer II. The assay time was 6 min and the throughput was 75 samples per hour. The sample volume was 40 microL and the measuring range was 0.25-7.90 mg/L. Imprecision studies revealed within-run CVs < 1.8% and between-run CVs < 1.8% in the concentration range 0.87-4.63 mg/L. Recovery was 92.4-101.3%. Linearity studies showed excellent correlation between the theoretical and obtained values. No interferences were detected from haemoglobin < 1.0 mmol/ L, bilirubin <512 micromol/L and Intralipid <20 g/L. Stability of cystatin C in serum was 7 days at temperatures from 20 degrees C to 20 degrees C and 6 months at -80 degrees C. Measurements of cystatin C in heparin-plasma and EDTA-plasma did not differ significantly from cystatin C measured in serum. Fifty patient samples run on the Dade Behring Nephelometer II (y) were compared to the Dako Cystatin C assay (x). The Passing-Bablok regression analysis revealed y = 1.105x - 0.340. In conclusion, the Dade Behring N Latex Cystatin C assay was precise and correlated with the Dako Cystatin C assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365519950185940

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 258

Metadata

Authors
Erlandsen, E. J., Randers, E., & Kristensen, J. H.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
1999-01
Volume
59
Issue
1
Pages
1-8
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2144367890
Cited by
258
References
2
FWCI
4.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System. https://app.cochat.ai/papers/10.1080/00365519950185940
The paper
Erlandsen, E. J., Randers, E., & Kristensen, J. H. (1999). Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365519950185940

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.