The DOI matches its Crossref record.
Magnetic Resonance Imaging Contrast Agent Targeted Toward Activated Platelets Allows In Vivo Detection of Thrombosis and Monitoring of Thrombolysis
Abstract
Background— Platelets are the key to thrombus formation and play a role in the development of atherosclerosis. Noninvasive imaging of activated platelets would be of great clinical interest. Here, we evaluate the ability of a magnetic resonance imaging (MRI) contrast agent consisting of microparticles of iron oxide (MPIOs) and a single-chain antibody targeting ligand-induced binding sites (LIBS) on activated glycoprotein IIb/IIIa to image carotid artery thrombi and atherosclerotic plaques. Methods and Results— Anti-LIBS antibody or control antibody was conjugated to 1-μm MPIOs (LIBS MPIO/control MPIO). Nonocclusive mural thrombi were induced in mice with 6% ferric chloride. MRI (at 9.4 T) was performed once before and repeatedly in 12-minute-long sequences after LIBS MPIO/control MPIO injection. After 36 minutes, a significant signal void, corresponding to MPIO accumulation, was observed with LIBS MPIOs but not control MPIOs ( P <0.05). After thrombolysis, in LIBS MPIO-injected mice, the signal void subsided, indicating successful thrombolysis. On histology, the MPIO content of the thrombus, as well as thrombus size, correlated significantly with LIBS MPIO-induced signal void (both P <0.01). After ex vivo incubation of symptomatic human carotid plaques, MRI and histology confirmed binding to areas of platelet adhesion/aggregation for LIBS MPIOs but not for control MPIOs. Conclusions— LIBS MPIOs allow in vivo MRI of activated platelets with excellent contrast properties and monitoring of thrombolytic therapy. Furthermore, activated platelets were detected on the surface of symptomatic human carotid plaques by ex vivo MRI. This approach represents a novel noninvasive technique allowing the detection and quantification of platelet-containing thrombi.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Leuschner, F., & Nahrendorf, M. (2011) · Circulation Research · doi:10.1161/circresaha.110.232678 · Cited by 110
Metadata
- Authors
- von zur Muhlen, C., von Elverfeldt, D., Moeller, J. A., Choudhury, R. P., Paul, D., Hagemeyer, C. E., Olschewski, M., Becker, A., Neudorfer, I., Bassler, N., Schwarz, M., Bode, C., & Peter, K.
- Venue
- Circulation
- Published
- 2008-07-15
- Volume
- 118
- Issue
- 3
- Pages
- 258-267
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2069888156
- Cited by
- 163
- References
- 0
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging Contrast Agent Targeted Toward Activated Platelets Allows In Vivo Detection of Thrombosis and Monitoring of Thrombolysis. https://app.cochat.ai/papers/10.1161/circulationaha.107.753657
- The paper
- von zur Muhlen, C., von Elverfeldt, D., Moeller, J. A., Choudhury, R. P., Paul, D., Hagemeyer, C. E., Olschewski, M., Becker, A., Neudorfer, I., Bassler, N., Schwarz, M., Bode, C., & Peter, K. (2008). Magnetic Resonance Imaging Contrast Agent Targeted Toward Activated Platelets Allows In Vivo Detection of Thrombosis and Monitoring of Thrombolysis. Circulation. https://doi.org/10.1161/circulationaha.107.753657
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.