The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Safety and Efficacy of Drug-Eluting and Bare Metal Stents: Comprehensive Meta-Analysis of Randomized Trials and Observational Studies
Abstract
Background— The safety and efficacy of drug-eluting stents (DES) among more generalized “real-world” patients than those enrolled in pivotal randomized controlled trials (RCTs) are controversial. We sought to perform a meta-analysis of DES studies to estimate the relative impact of DES versus bare metal stents (BMS) on safety and efficacy end points, particularly for non–Food and Drug Administration–labeled indications. Methods and Results— Comparative DES versus BMS studies published or presented through February 2008 with ≥100 total patients and reporting mortality data with cumulative follow-up of ≥1 year were identified. Data were abstracted from studies comparing DES with BMS; original source data were used when available. Data from 9470 patients in 22 RCTs and from 182 901 patients in 34 observational studies were included. RCT and observational data were analyzed separately. In RCTs, DES (compared with BMS) were associated with no detectable differences in overall mortality (hazard ratio [HR], 0.97; 95% confidence interval [CI], 0.81 to 1.15; P =0.72) or myocardial infarction (HR, 0.95; 95% CI, 0.79 to 1.13; P =0.54), with a significant 55% reduction in target vessel revascularization (HR, 0.45; 95% CI, 0.37 to 0.54; P <0.0001); point estimates were slightly lower in off-label compared with on-label analyses. In observational studies, DES were associated with significant reductions in mortality (HR, 0.78; 95% CI, 0.71 to 0.86), myocardial infarction (HR, 0.87; 95% CI, 0.78 to 0.97), and target vessel revascularization (HR, 0.54; 95% CI, 0.48 to 0.61) compared with BMS. Conclusions— In RCTs, no significant differences were observed in the long-term rates of death or myocardial infarction after DES or BMS use for either off-label or on-label indications. In real-world nonrandomized observational studies with greater numbers of patients but the admitted potential for selection bias and residual confounding, DES use was associated with reduced death and myocardial infarction. Both RCTs and observational studies demonstrated marked and comparable reductions in target vessel revascularization with DES compared with BMS. These data in aggregate suggest that DES are safe and efficacious in both on-label and off-label use but highlight differences between RCT and observational data comparing DES and BMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Operating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citationDaemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Self-citationColombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Analysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., Menichelli, M., Sabaté, M., Suttorp, M. J., Baumgart, D., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067484 · Cited by 1,006
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Bhatt, D. L., Flather, M. D., Hacke, W., Berger, P. B., Black, H. R., Boden, W. E., Cacoub, P., Cohen, E. A., Creager, M. A., Easton, J. D., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.025 · Cited by 805
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Self-citation2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Schampaert, E., Cohen, E. A., Schlüter, M., Reeves, F., Traboulsi, M., Title, L. M., Kuntz, R. E., & Popma, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.024 · Cited by 575
Sirolimus-Eluting versus Uncoated Stents in Acute Myocardial Infarction
Spaulding, C., Henry, P., Teiger, E., Beatt, K., Bramucci, E., Carrié, D., Slama, M. S., Merkely, B., Erglis, A., Margheri, M., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa062006 · Cited by 564
Effectiveness and Safety of Drug-Eluting Stents in Ontario
Tu, J. V., Bowen, J., Chiu, M., Ko, D. T., Austin, P. C., He, Y., Hopkins, R., Tarride, J.-E., Blackhouse, G., Lazzam, C., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071076 · Cited by 383
Self-citationClinical Outcomes and Stent Thrombosis Following Off-Label Use of Drug-Eluting Stents
Win, H. K., Caldera, A. E., Maresh, K., Lopez, J., Rihal, C. S., Parikh, M. A., Granada, J. F., Marulkar, S., Nassif, D., Cohen, D. J., et al. (2007) · JAMA · doi:10.1001/jama.297.18.2001 · Cited by 343
Randomized Clinical Trials and Observational Studies
Hannan, E. L. (2008) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.01.008 · Cited by 283
Self-citationA Comparison of Bare-Metal and Drug-Eluting Stents for Off-Label Indications
Marroquin, O. C., Selzer, F., Mulukutla, S. R., Williams, D. O., Vlachos, H. A., Wilensky, R. L., Tanguay, J.-F., Holper, E. M., Abbott, J. D., Lee, J. S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706258 · Cited by 270
Menichelli, M., Parma, A., Pucci, E., Fiorilli, R., Felice, F. D., Nazzaro, M. S., Giulivi, A., Alborino, D., Azzellino, A., & Violini, R. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.081 · Cited by 222
Doyle, B., Rihal, C. S., O’Sullivan, C. J., Lennon, R. J., Wiste, H. J., Bell, M., Bresnahan, J., & Holmes, D. R. (2007) · Circulation · doi:10.1161/circulationaha.107.707331 · Cited by 217
Stone, G. W., Ellis, S. G., Colombo, A., Dawkins, K. D., Grube, E., Cutlip, D. E., Friedman, M., Baim, D. S., & Koglin, J. (2007) · Circulation · doi:10.1161/circulationaha.106.687186 · Cited by 181
Self-citationSerruys, P. W. J. C., Ong, A. T. L., Morice, M., Bruyne, B. D., Colombo, A., Macaya, C., Richardt, G., Fajadet, J. C., Hamm, C. W., Dawkins, K. D., et al. (2005) · PubMed · Cited by 170
van der Hoeven, B. L., Liem, S., Jukema, J. W., Suraphakdee, N., Putter, H., Dijkstra, J., Atsma, D. E., Bootsma, M., Zeppenfeld, K., Oemrawsingh, P. V., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.056 · Cited by 160
Long-Term Clinical Outcomes Following Drug-eluting and Bare Metal Stenting in Massachusetts
Mauri, L., Silbaugh, T. S., Wolf, R., Zelevinsky, K., Lovett, A. F., Zhou, Z., Resnic, F. S., & Normand, S. (2008) · Circulation · doi:10.1161/circulationaha.108.781377 · Cited by 152
Williams, D. O., Abbott, J. D., & Kip, K. E. (2006) · Circulation · doi:10.1161/circulationaha.106.667915 · Cited by 150
Applegate, R. J., Sacrinty, M. T., Kutcher, M. A., dos Santos, R. M., Gandhi, S. K., Baki, T. T., & Little, W. C. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.064 · Cited by 95
Self-citationValgimigli, M., Campo, G. C., Arcozzi, C., Malagutti, P., Carletti, R., Ferrari, F., Barbieri, D., Parrinello, G., Percoco, G., & Ferrari, R. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.029 · Cited by 81
Cleophas, T. J., & Zwinderman, A. H. (2007) · Circulation · doi:10.1161/circulationaha.105.594960 · Cited by 67
Jeremias, A., & Kirtane, A. J. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-3-200802050-00199 · Cited by 57
Self-citationHoffmann, R., Stellbrink, E., Schröder, J. W., Gräwe, A., Vogel, G., Blindt, R., Kelm, M., & Radke, P. W. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.06.021 · Cited by 50
Harjai, K. J., Orshaw, P., Shenoy, C., Acharji, S., Sporn, D., Aboufares, A. F., & Stapleton, D. D. (2008) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2008.00380.x · Cited by 14
Self-citation
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Self-citationDeveloped with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
Metadata
- Authors
- Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., Park, S.-J., Perry, R., Racz, M., Saia, F., Tu, J. V., Waksman, R., Lansky, A. J., Mehran, R., & Stone, G. W.
- Venue
- Circulation
- Published
- 2009-06-30
- Volume
- 119
- Issue
- 25
- Pages
- 3198-3206
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2162162242
- Cited by
- 577
- References
- 33
- FWCI
- 76.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.