The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Model for End-Stage Liver Disease Score Predicts Left Ventricular Assist Device Operative Transfusion Requirements, Morbidity, and Mortality
Open accessAbstract
Background— The Model for End-Stage Liver Disease (MELD) predicts events in cirrhotic subjects undergoing major surgery and may offer similar prognostication in left ventricular assist device candidates with comparable degrees of multisystem dysfunction. Methods and Results— Preoperative MELD scores were calculated for subjects enrolled in the University of Michigan Health System (UMHS) mechanical circulatory support database. Univariate and multiple regression analyses were performed to investigate the ability of patient characteristics, laboratory data (including MELD scores), and hemodynamic measurements to predict total perioperative blood product exposure and operative mortality. The ability of preoperative MELD scores to predict operative mortality was evaluated in subjects enrolled in the Interagency Registry of Mechanically Assisted Circulatory Support (INTERMACS), and results were compared with those from the UMHS cohort. The mean±SD MELD scores for the UMHS (n=211) and INTERMACS (n=324) cohorts were 13.7±6.1 and 15.2±5.8, respectively, with 29 (14%) and 19 (6%) perioperative deaths. In the UMHS cohort, median total perioperative blood product exposure was 74 units (25th and 75th percentiles, 44 and 120 units). Each 5-unit MELD score increase was associated with 15.1±3.8 units (β±SE) of total perioperative blood product exposure. Each 10-unit increase in total perioperative blood product exposure increased the odds of operative death (odds ratio, 1.05; 95% confidence interval, 1.01 to 1.10). Odds ratios, measuring the ability of MELD scores to predict perioperative mortality, were 1.5 (95% confidence interval, 1.1 to 2.0) and 1.5 (95% confidence interval, 1.1 to 2.1) per 5 MELD units for the UMHS and INTERMACS cohorts, respectively. When MELD scores were dichotomized as ≥17 and <17, risk-adjusted Cox proportional-hazard ratios for 6-month mortality were 2.5 (95% confidence interval, 1.2 to 5.3) and 2.5 (95% confidence interval, 1.1 to 5.4) for the UMHS and INTERMACS cohorts, respectively. Conclusion— The MELD score identified left ventricular assist device candidates at high risk for perioperative bleeding and mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malinchoc, M., Kamath, P. S., Gordon, F. D., Peine, C. J., Rank, J., & ter Borg, P. C. J. (2000) · Hepatology · doi:10.1053/he.2000.5852 · Cited by 2,893
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371
Cited by
Mehra, M. R., Canter, C. E., Hannan, M. M., Semigran, M. J., Uber, P. A., Baran, D. A., Danziger-Isakov, L., Kirklin, J. K., Kirk, R., Kushwaha, S. S., et al. (2016) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2015.10.023 · Cited by 1,431
Feldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Self-citationInteractions of the heart and the liver
Møller, S., & Bernardi, M. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht246 · Cited by 490
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Heart Failure and Liver Disease
Xanthopoulos, A., Starling, R. C., Kitai, T., & Triposkiadis, F. (2019) · JACC: Heart Failure · doi:10.1016/j.jchf.2018.10.007 · Cited by 341
Metadata
- Authors
- Matthews, J. C., Pagani, F. D., Haft, J. W., Koelling, T. M., Naftel, D. C., & Aaronson, K. D.
- Venue
- Circulation
- Published
- 2010-01-19
- Volume
- 121
- Issue
- 2
- Pages
- 214-220
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2087248947
- Cited by
- 200
- References
- 2
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.