Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record.

Comparisons of Baseline Demographics, Clinical Presentation, and Long-Term Outcome Among Patients With Early, Late, and Very Late Stent Thrombosis of Sirolimus-Eluting Stents: Observations From the Registry of Stent Thrombosis for Review and Reevaluation (RESTART)

Open access
Kimura, Takeshi, Morimoto, Takeshi, Kozuma, Ken, Honda, Yasuhiro, Kume, Teruyoshi, Aizawa, Tadanori, Mitsudo, Kazuaki, Miyazaki, Shunichi, Yamaguchi, Tetsu, Hiyoshi, Emi, Nishimura, Eizo, Isshiki, Takaaki·2010·Circulation

Abstract

Background— Stent thrombosis (ST) after sirolimus-eluting stent implantation has not yet been adequately characterized, mainly because of its low incidence. Methods and Results— The Registry of Stent Thrombosis for Review and Reevaluation (RESTART) is a Japanese nationwide registry of sirolimus-eluting stent–associated ST comprising 611 patients with definite ST (early [within 30 days; EST], 322 patients; late [between 31 and 365 days; LST], 105 patients; and very late [>1 year; VLST], 184 patients). Baseline demographics, clinical presentation, and long-term outcome of sirolimus-eluting stent–associated ST were compared among patients with EST, LST, and VLST. Baseline demographics were significantly different according to the timing of ST. Characteristic demographic factors for LST/VLST versus EST identified by multivariable model were hemodialysis, end-stage renal disease not on hemodialysis, absence of circumflex target, target of chronic total occlusion, prior percutaneous coronary intervention, and age <65 years. For LST versus VLST, they were hemodialysis, heart failure, insulin-dependent diabetes mellitus, and low body mass index. Patients with LST had a significantly higher rate of Thrombolysis in Myocardial Infarction grade 2/3 flow (36%) at the time of ST than those with EST (13%) ( P <0.0001) and VLST (17%; P <0.0001). Mortality rate at 1 year after ST was significantly lower in patients with VLST (10.5%) compared with those with EST (22.4%; P =0.003) or LST (23.5%; P =0.009). Conclusion— ST timing–dependent differences in baseline demographic features, Thrombolysis in Myocardial Infarction flow grade, and mortality rate suggest possible differences in the predominant pathophysiological mechanisms of ST according to timing after sirolimus-eluting stent implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.903955

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Kimura, T., Morimoto, T., Kozuma, K., Honda, Y., Kume, T., Aizawa, T., Mitsudo, K., Miyazaki, S., Yamaguchi, T., Hiyoshi, E., Nishimura, E., & Isshiki, T.
Venue
Circulation
Published
2010-07-06
Volume
122
Issue
1
Pages
52-61
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2092885086
Cited by
238
References
0
FWCI
24.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparisons of Baseline Demographics, Clinical Presentation, and Long-Term Outcome Among Patients With Early, Late, and Very Late Stent Thrombosis of Sirolimus-Eluting Stents: Observations From the Registry of Stent Thrombosis for Review and Reevaluation (RESTART). https://app.cochat.ai/papers/10.1161/circulationaha.109.903955
The paper
Kimura, T., Morimoto, T., Kozuma, K., Honda, Y., Kume, T., Aizawa, T., Mitsudo, K., Miyazaki, S., Yamaguchi, T., Hiyoshi, E., Nishimura, E., & Isshiki, T. (2010). Comparisons of Baseline Demographics, Clinical Presentation, and Long-Term Outcome Among Patients With Early, Late, and Very Late Stent Thrombosis of Sirolimus-Eluting Stents: Observations From the Registry of Stent Thrombosis for Review and Reevaluation (RESTART). Circulation. https://doi.org/10.1161/circulationaha.109.903955

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.