Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Repolarization Alternans Reveals Vulnerability to Human Atrial Fibrillation

Open access
Narayan, Sanjiv M., Franz, Michael R., Clopton, Paul, Pruvot, Etienne J., Krummen, David E. · 2011 · Circulation

Abstract

Background—: The substrates for human atrial fibrillation (AF) are poorly understood, but involve abnormal repolarization (action potential duration [APD]). We hypothesized that beat-to-beat oscillations in APD may explain AF substrates, and why vulnerability to AF forms a spectrum from control subjects without AF to patients with paroxysmal then persistent AF. Methods and Results—: In 33 subjects (12 with persistent AF, 13 with paroxysmal AF, and 8 controls without AF), we recorded left (n=33) and right (n=6) atrial APD on pacing from cycle lengths 600 to 500 ms (100 to 120 bpm) up to the point where AF initiated. Action potential duration alternans required progressively faster rates for patients with persistent AF, patients with paroxysmal AF, and controls (cycle length 411±94 versus 372±72 versus 218±33 ms; P <0.01). In AF patients, APD alternans occurred at rates as slow as 100 to 120 bpm, unrelated to APD restitution ( P >0.10). In this milieu, spontaneous ectopy initiated AF. At fast rates, APD alternans disorganized to complex oscillations en route to AF. Complex oscillations also arose at progressively faster rates for persistent AF, paroxysmal AF, and controls (cycle length: 316±99 versus 266±19 versus 177±16 ms; P =0.02). In paroxysmal AF, APD oscillations amplified before AF ( P <0.001). In controls, APD alternans arose only at very fast rates (cycle length <250 ms; P <0.001 versus AF groups) just preceding AF. In 4 AF patients in whom rapid pacing did not initiate AF, APD alternans arose transiently then extinguished. Conclusions—: Atrial APD alternans reveals dynamic substrates for AF, arising most readily (at lower rates and higher magnitudes) in persistent AF then paroxysmal AF, and least readily in controls. APD alternans preceded all AF episodes and was absent when AF did not initiate. The cellular mechanisms for APD alternans near resting heart rates require definition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.977827

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 190

Metadata

Authors
Narayan, S. M., Franz, M. R., Clopton, P., Pruvot, E. J., & Krummen, D. E.
Venue
Circulation
Published
2011-06-28
Volume
123
Issue
25
Pages
2922-2930
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1998730638
Cited by
190
References
2
FWCI
11.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repolarization Alternans Reveals Vulnerability to Human Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circulationaha.110.977827
The paper
Narayan, S. M., Franz, M. R., Clopton, P., Pruvot, E. J., & Krummen, D. E. (2011). Repolarization Alternans Reveals Vulnerability to Human Atrial Fibrillation. Circulation. https://doi.org/10.1161/circulationaha.110.977827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.