CoChat

Trends in Use of Implantable Cardioverter-Defibrillator Therapy Among Patients Hospitalized for Heart Failure: Have the Previously Observed Sex and Racial Disparities Changed Over Time?

Open access
Al-Khatib, Sana M., Hellkamp, Anne S., Hernandez, Adrian F., Fonarow, Gregg C., Thomas, Kevin L., Al-Khalidi, Hussein R., Heidenreich, Paul A., Hammill, Stephen, Yancy, Clyde, Peterson, Eric D., for the Get With the Guidelines Steering Committee and Hospitals · 2012 · Circulation
Cited by 139

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background—: Prior studies have demonstrated low use of implantable cardioverter defibrillators (ICDs) as primary prevention, particularly among women and blacks. The degree to which the overall use of ICD therapy and disparities in use have changed is unclear. Methods and Results—: We examined 11 880 unique patients with a history of heart failure and left ventricular ejection fraction ≤35% who were ≥65 years old and enrolled in the Get With the Guidelines–Heart Failure (GWTG-HF) program from January 2005 through December 2009. We determined the rate of ICD use by year for the overall population and for sex and race groups. From 2005 to 2007, overall ICD use increased from 30.2% to 42.4% and then remained unchanged in 2008 to 2009. After adjustment for potential confounders, ICD use increased significantly in the overall study population during 2005 to 2007 (odds ratio, 1.28; 95% confidence interval, 1.11–1.48 per year; P =0.0008) and in black women (odds ratio, 1.82; 95% confidence interval, 1.28–2.58 per year; P =0.0008), white women (odds ratio, 1.30; 95% confidence interval, 1.06–1.59 per year; P =0.010), black men (odds ratio, 1.54; 95% confidence interval, 1.19–1.99 per year; P =0.0009), and white men (odds ratio, 1.25; 95% confidence interval, 1.06–1.48 per year; P =0.0072). The increase in ICD use was greatest among blacks. Conclusions—: In the GWTG-HF quality improvement program, a significant increase in ICD therapy use was observed over time in all sex and race groups. The previously described racial disparities in ICD use were no longer present by the end of the study period; however, sex differences persisted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.111.066605

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 139

Metadata

Authors
Al-Khatib, S. M., Hellkamp, A. S., Hernandez, A. F., Fonarow, G. C., Thomas, K. L., Al-Khalidi, H. R., Heidenreich, P. A., Hammill, S., Yancy, C., Peterson, E. D., & for the Get With the Guidelines Steering Committee and Hospitals
Venue
Circulation
Published
2012-03-06
Volume
125
Issue
9
Pages
1094-1101
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2044150913
Cited by
139
References
6
FWCI
8.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trends in Use of Implantable Cardioverter-Defibrillator Therapy Among Patients Hospitalized for Heart Failure: Have the Previously Observed Sex and Racial Disparities Changed Over Time? https://app.cochat.ai/papers/10.1161/circulationaha.111.066605
The paper
Al-Khatib, S. M., Hellkamp, A. S., Hernandez, A. F., Fonarow, G. C., Thomas, K. L., Al-Khalidi, H. R., Heidenreich, P. A., Hammill, S., Yancy, C., Peterson, E. D., & for the Get With the Guidelines Steering Committee and Hospitals. (2012). Trends in Use of Implantable Cardioverter-Defibrillator Therapy Among Patients Hospitalized for Heart Failure: Have the Previously Observed Sex and Racial Disparities Changed Over Time? Circulation. https://doi.org/10.1161/circulationaha.111.066605

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.