The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement
Abstract
Background—: Recent transcatheter aortic valve replacement studies have raised concerns about adverse cerebrovascular events. The etiopathology of the embolized material is currently unknown. Methods and Results—: A total of 40 patients underwent transcatheter aortic valve replacement with the use of a dual filter–based embolic protection device (Montage Dual Filter System, Claret Medical, Inc). Macroscopic material liberated during the transcatheter aortic valve replacement procedure was captured in the device filter baskets in 30 (75%) patients and sent for histopathologic analysis. The captured material varied in size from 0.15 to 4.0 mm. Amorphous calcified material (size, 0.55–1.8 mm) was identified in 5 patients (17%). In 8 patients (27%), the captured material (size, 0.25–4.0 mm) contained valve tissue composed of loose connective tissue (collagen and elastic fibers) with focal areas of myxoid stroma, with or without coverage by endothelial cells and intermixed with fibrin. In another 13 (43%) patients, collagenous tissue, which may represent elements of vessel wall and valvelike structures, was identified. In 9 patients (30%), thrombotic material was intermixed with neutrophils (size, 0.15–2.0 mm). Overall, thrombotic material was found in 52% of patients, and tissue fragments compatible with aortic valve leaflet or aortic wall origin were found in 52% (21/40) of patients. Conclusions—: Embolic debris traveling to the brain was captured in 75% of transcatheter aortic valve replacement procedures where a filter-based embolic protection device was used. The debris consisted of fibrin, or amorphous calcium and connective tissue derived most likely from either the native aortic valve leaflets or aortic wall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationStandardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Self-citationGénéreux, P., Head, S. J., Van Mieghem, N. M., Kodali, S., Kirtane, A. J., Xu, K., Smith, C., Serruys, P. W., Kappetein, A. P., & Leon, M. B. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.022 · Cited by 593
Self-citationKahlert, P., Knipp, S. C., Schlamann, M., Thielmann, M., Al-Rashid, F., Weber, M., Johansson, U., Wendt, D., Jakob, H. G., Forsting, M., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.855866 · Cited by 521
Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation
Ghanem, A., Müller, A., Nähle, C. P., Kocurek, J., Werner, N., Hammerstingl, C., Schild, H. H., Schwab, J. O., Mellert, F., Fimmers, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.026 · Cited by 345
Cerebral Embolization During Transcatheter Aortic Valve Implantation: A Transcranial Doppler Study
Kahlert, P., Al-Rashid, F., Döttger, P., Mori, K., Plicht, B., Wendt, D., Bergmann, L., Kottenberg, E., Schlamann, M., Mummel, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.092544 · Cited by 335
Central nervous system injury associated with cardiac surgery
Newman, M. F., Mathew, J. P., Grocott, H. P., Mackensen, G. B., Monk, T., Welsh-Bohmer, K. A., Blumenthal, J. A., Laskowitz, D. T., & Mark, D. B. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69254-4 · Cited by 327
Cerebral Embolism Following Transcatheter Aortic Valve Implantation
Rodés-Cabau, J., Dumont, E., Boone, R. H., Larose, E., Bagur, R., Gurvitch, R., Bédard, F., Doyle, D., De Larochellière, R., Jayasuria, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.036 · Cited by 298
Cited by
Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement
Kapadia, S. R., Kodali, S., Makkar, R., Mehran, R., Lazar, R. M., Zivadinov, R., Dwyer, M. G., Jilaihawi, H., Virmani, R., Anwaruddin, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.023 · Cited by 509
Self-citationProsthetic Heart Valve Thrombosis
Dangas, G. D., Weitz, J. I., Giustino, G., Makkar, R., & Mehran, R. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.09.958 · Cited by 502
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., et al. (2016) · JAMA · doi:10.1001/jama.2016.10302 · Cited by 367
Rodés-Cabau, J., Masson, J.-B., Welsh, R. C., Garcia del Blanco, B., Pelletier, M., Webb, J. G., Al-Qoofi, F., Généreux, P., Maluenda, G., Thoenes, M., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.04.014 · Cited by 331
Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement
Kapadia, S. R., Makkar, R., Leon, M., Abdel-Wahab, M., Waggoner, T., Massberg, S., Rottbauer, W., Horr, S., Sondergaard, L., Karha, J., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2204961 · Cited by 325
Metadata
- Authors
- Van Mieghem, N. M., Schipper, M. E. I., Ladich, E., Faqiri, E., van der Boon, R., Randjgari, A., Schultz, C., Moelker, A., van Geuns, R.-J., Otsuka, F., Serruys, P. W., Virmani, R., & de Jaegere, P. P.
- Venue
- Circulation
- Published
- 2013-06-04
- Volume
- 127
- Issue
- 22
- Pages
- 2194-2201
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2057546425
- Cited by
- 263
- References
- 20
- FWCI
- 16.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1161/circulationaha.112.001091
- The paper
- Van Mieghem, N. M., Schipper, M. E. I., Ladich, E., Faqiri, E., van der Boon, R., Randjgari, A., Schultz, C., Moelker, A., van Geuns, R.-J., Otsuka, F., Serruys, P. W., Virmani, R., & de Jaegere, P. P. (2013). Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement. Circulation. https://doi.org/10.1161/circulationaha.112.001091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.