Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement: Current Knowledge
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
New Drugs and Technologies 397T ranscatheter aortic valve replacement (TAVR) is now well-established as the standard of care for patients with severe symptomatic aortic stenosis who are deemed inoperable, 1 and is seen as an alternative treatment option to surgical aortic valve replacement (SAVR) in a subset of patients with high postoperative mortality.2 The native valve is typically not removed but instead crushed by the superimposed bioprosthesis, which can result in an incomplete seal of the bioprosthetic valve and aortic annulus, with subsequent occurrence of paravalvular leak (PVL).Two types of Transcatheter Heart Valves (THV) that have been widely used, the balloon-expandable Edwards valve (Cribier-Edwards, Edwards SAPIEN and Edwards SAPIEN XT) by Edwards Lifesciences, and the selfexpandable CoreValve by Medtronic, have been described in detail elsewhere. 3,4Despite the evolving technology of transcatheter valves, PVL post-TAVR is common, with a wide range of reported incidences (Table 1).Most importantly, PVL has been associated with increased short-and long-term mortality post-TAVR, and is seen as a barrier to more widespread use of this promising technique.[5][6][7][8][9][10][11][12][13] This article describes the incidence, causes, and predictors of PVL, as well as its impact on clinical outcomes.Methods of prevention, diagnosis, and treatment of PVL are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 1×
“The Agatston Score is derived from ECG-gated multislice contrast-enhanced computed tomography and has been used to characterize total valve and individual cusp calcification.(42) High Agatston Score was correlated with higher degrees of PVL as well as the need for repeat maneuvers during implantation.”
MethodTranscatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345 · cited 1×
“397 Transcatheter aortic valve replacement (TAVR) is now well-established as the standard of care for patients with severe symptomatic aortic stenosis who are deemed inoperable,(1) and is seen as an alternative treatment option to surgical aortic valve replacement (SAVR) in a subset of patients with high postoperative…”
BackgroundRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884 · cited 1×
“6% with the Edwards implants).(13) This finding has not been replicated in other studies.”
ResultTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306 · cited 1×
“Two types of Transcatheter Heart Valves (THV) that have been widely used, the balloon-expandable Edwards valve (Cribier-Edwards, Edwards SAPIEN and Edwards SAPIEN XT) by Edwards Lifesciences, and the selfexpandable CoreValve by Medtronic, have been described in detail elsewhere.(3,4) Despite the evolving technology of…”
Method
Cited by
Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu384 · Cited by 446
Self-citationAccurate Assessment of Aortic Stenosis: A Review of Diagnostic Modalities and Hemodynamics
Saikrishnan, N., Kumar, G., Sawaya, F. J., Lerakis, S., & Yoganathan, A. P. (2014) · Circulation · doi:10.1161/circulationaha.113.002310 · Cited by 182
Self-citationCurrent progress in tissue engineering of heart valves: multiscale problems, multiscale solutions
Cheung, D. Y., Duan, B., & Butcher, J. T. (2015) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2015.1051527 · Cited by 160
“However, for the transcatheter treatment to be completely viable, it must overcome the challenge of the high incidence of paravalvular leakages (50 -- 85%) in current TAVI/TAVR procedures [95].”
Background
Metadata
- Authors
- Lerakis, S., Hayek, S. S., & Douglas, P. S.
- Venue
- Circulation
- Published
- 2013-01-22
- Volume
- 127
- Issue
- 3
- Pages
- 397-407
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1984782104
- Cited by
- 215
- References
- 6
- FWCI
- 19.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement: Current Knowledge. https://app.cochat.ai/papers/10.1161/circulationaha.112.142000
- The paper
- Lerakis, S., Hayek, S. S., & Douglas, P. S. (2013). Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement: Current Knowledge. Circulation. https://doi.org/10.1161/circulationaha.112.142000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.