The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement
Open accessAbstract
Background—: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results—: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P <0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P <0.001) and balloon postdilatation (22.6% versus 0.0%, P =0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23–36.91; P <0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67–26.33; P <0.001) were associated with aortic root contained/noncontained rupture. Conclusions—: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationGénéreux, P., Head, S. J., Van Mieghem, N. M., Kodali, S., Kirtane, A. J., Xu, K., Smith, C., Serruys, P. W., Kappetein, A. P., & Leon, M. B. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.022 · Cited by 593
Self-citationNoninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Self-citationJilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Self-citationWillson, A. B., Webb, J. G., LaBounty, T. M., Achenbach, S., Moss, R., Wheeler, M., Thompson, C., Min, J. K., Gurvitch, R., Norgaard, B. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.015 · Cited by 407
Self-citationMultidetector Computed Tomography in Transcatheter Aortic Valve Implantation
Leipsic, J., Gurvitch, R., LaBounty, T. M., Min, J. K., Wood, D., Johnson, M., Ajlan, A. M., Wijesinghe, N., & Webb, J. G. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.014 · Cited by 287
Self-citationEwe, S. H., Ng, A. C. T., Schuijf, J. D., van der Kley, F., Colli, A., Palmen, M., de Weger, A., Marsan, N. A., Holman, E. R., de Roos, A., et al. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.07.007 · Cited by 227
Hamdan, A., Guetta, V., Konen, E., Goitein, O., Segev, A., Raanani, E., Spiegelstein, D., Hay, I., Di Segni, E., Eldar, M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.045 · Cited by 195
Blanke, P., Reinöhl, J., Schlensak, C., Siepe, M., Pache, G., Euringer, W., Geibel-Zehender, A., Bode, C., Langer, M., Beyersdorf, F., et al. (2012) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.111.967349 · Cited by 158
Self-citationWillson, A. B., Webb, J. G., Freeman, M., Wood, D. A., Gurvitch, R., Thompson, C., Moss, R., Toggweiler, S., Binder, R., Munt, B. I., et al. (2012) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2012.10.002 · Cited by 98
Self-citationRupture of the Device Landing Zone During Transcatheter Aortic Valve Implantation
Pašić, M., Unbehaun, A., Dreysse, S. T., Buz, S., Drews, T., Kukucka, M., D’Ancona, G., Seifert, B., & Hetzer, R. (2012) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.967315 · Cited by 96
Binder, R. K., Rodés‐Cabau, J., Wood, D. A., & Webb, J. G. (2012) · EuroIntervention · doi:10.4244/eijv8sqa15 · Cited by 56
Self-citationTransfemoral Aortic Valve Replacement with the SAPIEN XT Valve: Step-by-Step
Willson, A., Toggweiler, S., & Webb, J. G. (2011) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2011.04.005 · Cited by 28
Self-citation
Cited by
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
VARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citationAbdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., et al. (2014) · JAMA · doi:10.1001/jama.2014.3316 · Cited by 686
Blanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Nørgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.12.003 · Cited by 610
Self-citation
Metadata
- Authors
- Barbanti, M., Yang, T.-H., Rodès Cabau, J., Tamburino, C., Wood, D. A., Jilaihawi, H., Blanke, P., Makkar, R. R., Latib, A., Colombo, A., Tarantini, G., Raju, R., Binder, R. K., Nguyen, G., Freeman, M., Ribeiro, H. B., Kapadia, S., Min, J., Feuchtner, G., Gurtvich, R., Alqoofi, F., Pelletier, M., Ussia, G. P., Napodano, M., de Brito, F. S., Kodali, S., Norgaard, B. L., Hansson, N. C., Pache, G., Canovas, S. J., Zhang, H., Leon, M. B., Webb, J. G., & Leipsic, J.
- Venue
- Circulation
- Published
- 2013-07-16
- Volume
- 128
- Issue
- 3
- Pages
- 244-253
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2143427268
- Cited by
- 601
- References
- 14
- FWCI
- 31.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.