In Utero Diagnosis of Long QT Syndrome by Magnetocardiography
Open accessThe DOI matches its Crossref record.
Abstract
Background—: The electrophysiology of long QT syndrome (LQTS) in utero is virtually unstudied. Our goal here was to evaluate the efficacy of fetal magnetocardiography (fMCG) for diagnosis and prognosis of fetuses at risk of LQTS. Methods and Results—: We reviewed the pre/postnatal medical records of 30 fetuses referred for fMCG because of a family history of LQTS (n=17); neonatal/childhood sudden cardiac death (n=3), or presentation of prenatal LQTS rhythms (n=12): 2° atrioventricular block, ventricular tachycardia, heart rate < 3 rd percentile. We evaluated heart rate and reactivity, cardiac time intervals, T-wave characteristics, and initiation/termination of Torsade de Pointes, and compared these with neonatal ECG findings. After birth, subjects were tested for LQTS mutations. Based on accepted clinical criteria, 21 subjects (70%; 9 KCNQ1, 5 KCNH2, 2 SCN5A, 2 other, 3 untested) had LQTS. Using a threshold of corrected QT= 490 ms, fMCG accurately identified LQTS fetuses with 89% (24/27) sensitivity and 89% (8/9) specificity in 36 sessions. Four fetuses (2 KCNH2 and 2 SCN5A), all with corrected QT ≥ 620 ms, had frequent episodes of Torsade de Pointes, which were present 22–79% of the time. Although some episodes initiated with a long-short sequence, most initiations showed QRS aberrancy and a notable lack of pause dependency. T-wave alternans was strongly associated with severe LQTS phenotype. Conclusions—: Corrected QT prolongation (≥490 ms) assessed by fMCG accurately identified LQTS in utero; extreme corrected QT prolongation (≥620 ms) predicted Torsade de Pointes. FMCG can play a critical role in the diagnosis and management of fetuses at risk of LQTS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“and measurement of the QTc by fMCG or fetal electrocardiography if available.(436) Fetal treatment is not recommended”
MethodSelf-citationStrand, S., Lutter, W., Strasburger, J. F., Shah, V., Baffa, O., & Wakai, R. T. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.013436 · Cited by 136
Self-citationJensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Wacker‐Gussmann, A., Strasburger, J. F., & Wakai, R. T. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.025224 · Cited by 58
Self-citationBrala, D., Thevathasan, T., Grahl, S., Barrow, S., Violano, M., Bergs, H., Golpour, A., Suwalski, P., Poller, W., Skurk, C., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.027619 · Cited by 54
Complex and novel arrhythmias precede stillbirth in fetuses with de novo long QT syndrome
Strand, S., Strasburger, J. F., Cuneo, B. F., & Wakai, R. T. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.119.008082 · Cited by 50
Self-citationTao, R., Zhang, S., Zhang, R., Shen, C., Ma, J., Cui, J., Chen, Y., Wang, B., Li, H., Xie, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90615-x · Cited by 14
Ultra-sensitive vector magnetometer for magnetocardiographic mapping
Gusev, N. A., Vetoshko, P. M., Kuzmichev, A. N., Chepurnova, D. A., Samoilova, E. V., Zvezdin, A. K., Korotaeva, A. A., & Belotelov, V. I. (2017) · Biomedical Engineering · doi:10.1007/s10527-017-9705-8 · Cited by 9
Metadata
- Authors
- Cuneo, B. F., Strasburger, J. F., Yu, S., Horigome, H., Hosono, T., Kandori, A., & Wakai, R. T.
- Venue
- Circulation
- Published
- 2013-11-12
- Volume
- 128
- Issue
- 20
- Pages
- 2183-2191
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2085752358
- Cited by
- 118
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.