Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.

Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer

Open access

Abstract

Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which allows one to study the function of excitable human organs with a sensor placed outside the human body. For instance, magnetometers can be used to detect brain activity or to study the activity of the heart. We have developed a highly sensitive miniature optically pumped magnetometer based on cesium atomic vapor kept in a paraffin-coated glass container. The magnetometer is optimized for detection of biological signals and has high temporal and spatial resolution. It is operated at room- or human body temperature and can be placed in contact with or at a mm-distance from a biological object. With this magnetometer, we detected the heartbeat of an isolated guinea-pig heart, which is an animal widely used in biomedical studies. In our recordings of the magnetocardiogram, we can detect the P-wave, QRS-complex and T-wave associated with the cardiac cycle in real time. We also demonstrate that our device is capable of measuring the cardiac electrographic intervals, such as the RR- and QT-interval, and detecting drug-induced prolongation of the QT-interval, which is important for medical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-34535-z

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Electrical recording on an isolated guinea-pig heart placed in a Langendorff setup. (a) Electrocardiogram showing the P-wave, the QRS-complex and the T-wave. Electrographic intervals RR and QT are depicted with arrows. (b) Power spectral density of the electrocardiogram of a single heartbeat lasting approximately 0.25 s (RR = 247 ms corresponding to 243 bpm).
Figure 1 Electrical recording on an isolated guinea-pig heart placed in a Langendorff setup. (a) Electrocardiogram showing the P-wave, the QRS-complex and the T-wave. Electrographic intervals RR and QT are depicted with arrows. (b) Power spectral density of the electrocardiogram of a single heartbeat lasting approximately 0.25 s (RR = 247 ms corresponding to 243 bpm).CC BY · PubMed Central
Figure 2 Experimental setup. (a) Picture of the cesium vapor cell. (b) Schematics of the experimental setup. λ/2: half-wave plate, PBS: polarizing beamsplitter. The magnetic field from the heart affects the cesium atomic spins which in turn rotates the polarization of the probe light by an angle θ. This polarization rotation is detected with a balanced polarimeter (shown inside the dashed-line box). (c) Cesium atom level scheme and laser frequencies.
Figure 2 Experimental setup. (a) Picture of the cesium vapor cell. (b) Schematics of the experimental setup. λ/2: half-wave plate, PBS: polarizing beamsplitter. The magnetic field from the heart affects the cesium atomic spins which in turn rotates the polarization of the probe light by an angle θ. This polarization rotation is detected with a balanced polarimeter (shown inside the dashed-line box). (c) Cesium atom level scheme and laser frequencies.CC BY · PubMed Central
Figure 3 Magnetic field measurements. (a) Magnetometer signal in volts. Solid line: 100 μs square magnetic pulse applied. Dashed line: single sine wave magnetic pulse with 10 ms period applied. Signals have been averaged 10 times. (b) Magnetic field in nT as calculated by deconvolving the signals in (a). (c) Magnetometer noise spectrum in V/√Hz (without any applied magnetic field). Noise spectrum has been averaged 10 times. (d) Noise spectrum in pT/√Hz. The temperature ≈26 °C of the cesium vapor cell was slightly above room temperature.
Figure 3 Magnetic field measurements. (a) Magnetometer signal in volts. Solid line: 100 μs square magnetic pulse applied. Dashed line: single sine wave magnetic pulse with 10 ms period applied. Signals have been averaged 10 times. (b) Magnetic field in nT as calculated by deconvolving the signals in (a). (c) Magnetometer noise spectrum in V/√Hz (without any applied magnetic field). Noise spectrum has been averaged 10 times. (d) Noise spectrum in pT/√Hz. The temperature ≈26 °C of the cesium vapor cell was slightly above room temperature.CC BY · PubMed Central
Figure 4 Guinea-pig heart and the magnetocardiogram. (a) Picture of an isolated guinea-pig heart inside a plastic chamber. (b) Example of a magnetometer signal (without averaging) in volts when a guinea-pig heart is placed close to the magnetometer. (c) Magnetic field from the heart in pT. The deconvoluted signal was low-pass filtered using a Type I Chebyshev filter with a cut-off frequency of 250 Hz to supress high-frequency noise. The temperature ≈26 °C of the cesium vapor cell was slightly above room temperature due to heating from the heart which was perfused with ≈37 °C warm physiological solution.
Figure 4 Guinea-pig heart and the magnetocardiogram. (a) Picture of an isolated guinea-pig heart inside a plastic chamber. (b) Example of a magnetometer signal (without averaging) in volts when a guinea-pig heart is placed close to the magnetometer. (c) Magnetic field from the heart in pT. The deconvoluted signal was low-pass filtered using a Type I Chebyshev filter with a cut-off frequency of 250 Hz to supress high-frequency noise. The temperature ≈26 °C of the cesium vapor cell was slightly above room temperature due to heating from the heart which was perfused with ≈37 °C warm physiological solution.CC BY · PubMed Central
Figure 5 Peak-to-peak value of the QRS complex as a function of distance between the heart and magnetometer.
Figure 5 Peak-to-peak value of the QRS complex as a function of distance between the heart and magnetometer.CC BY · PubMed Central
Figure 6 Effects of IKr inhibition on heart rate and QT-interval. (a) Example magnetometer signals recorded before and after administration of 0.06 μM E-4031. Traces are the averages of approximately 10 heartbeats. (b) Heart rate in beats per minute: bpm = 60/RR-interval [s]. Points are mean values averaged over 5 animals. Error bars represent the standard error of the mean. (c) QT-interval corrected for heart rate (Bazett correction35). In (b and c), heart rate and QT-intervals are measured before (t = 0 data points) and 5, 10, 15, and 20 minutes after administration of the drug.
Figure 6 Effects of IKr inhibition on heart rate and QT-interval. (a) Example magnetometer signals recorded before and after administration of 0.06 μM E-4031. Traces are the averages of approximately 10 heartbeats. (b) Heart rate in beats per minute: bpm = 60/RR-interval [s]. Points are mean values averaged over 5 animals. Error bars represent the standard error of the mean. (c) QT-interval corrected for heart rate (Bazett correction35). In (b and c), heart rate and QT-intervals are measured before (t = 0 data points) and 5, 10, 15, and 20 minutes after administration of the drug.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 84

Metadata

Authors
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S.
Affiliations
University of Copenhagen (DK)
Corresponding author
Jensen, Kasper
Venue
Scientific Reports
Published
2018-11-01
Volume
8
Issue
1
Pages
16218-16218
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2810392889
Cited by
79
References
35
Citations by year
2026: 3 · 2025: 9 · 2024: 12 · 2023: 17 · 2022: 9 · 2021: 14 · 2020: 8 · 2019: 7
FWCI
3.35
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Innovationsfonden
  • Army Research Office (W911NF, W911NF-11-0235, W911NF-11)
  • Army Research Laboratory (W911NF)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
magnetocardiography, optically pumped magnetometers, room-temperature magnetometry, isolated guinea pig heart, cardiac magnetic field, P wave, QRS complex, T wave, QT interval, RR interval, drug-induced QT prolongation, cardiac electrophysiology
MeSH terms
Algorithms, Animals, Electrocardiography, Guinea Pigs, Heart, Humans, Models, Biological, Temperature, Electrophysiologic Techniques, Cardiac, Magnetocardiography, Magnetometry, Optical Imaging, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer. https://app.cochat.ai/papers/10.1038/s41598-018-34535-z
The paper
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018). Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer. Scientific Reports. https://doi.org/10.1038/s41598-018-34535-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.