The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer
Open accessAbstract
Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which allows one to study the function of excitable human organs with a sensor placed outside the human body. For instance, magnetometers can be used to detect brain activity or to study the activity of the heart. We have developed a highly sensitive miniature optically pumped magnetometer based on cesium atomic vapor kept in a paraffin-coated glass container. The magnetometer is optimized for detection of biological signals and has high temporal and spatial resolution. It is operated at room- or human body temperature and can be placed in contact with or at a mm-distance from a biological object. With this magnetometer, we detected the heartbeat of an isolated guinea-pig heart, which is an animal widely used in biomedical studies. In our recordings of the magnetocardiogram, we can detect the P-wave, QRS-complex and T-wave associated with the cardiac cycle in real time. We also demonstrate that our device is capable of measuring the cardiac electrographic intervals, such as the RR- and QT-interval, and detecting drug-induced prolongation of the QT-interval, which is important for medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





![Figure 6 Effects of IKr inhibition on heart rate and QT-interval. (a) Example magnetometer signals recorded before and after administration of 0.06 μM E-4031. Traces are the averages of approximately 10 heartbeats. (b) Heart rate in beats per minute: bpm = 60/RR-interval [s]. Points are mean values averaged over 5 animals. Error bars represent the standard error of the mean. (c) QT-interval corrected for heart rate (Bazett correction35). In (b and c), heart rate and QT-intervals are measured before (t = 0 data points) and 5, 10, 15, and 20 minutes after administration of the drug.](https://figures.cochat.ai/paper-figures/3abc85d8d19d46caa7a28246e4418af6/magnetocardiography-on-an-isolated-animal-heart-with-a-room-temperature-figure-6.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Moreover, MCG has proven useful for the non-invasive study of experimental intact animals (84) and contactless high-resolution investigation of experimental electrophysiology of isolated heart (85) and cardiac tissue models (86).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Prevalence of the Congenital Long-QT Syndrome
Schwartz, P. J., Stramba-Badiale, M., Crotti, L., Pedrazzini, M., Besana, A., Bosi, G., Gabbarini, F., Goulene, K., Insolia, R., Mannarino, S., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.863209 · Cited by 1,072
(2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181aef106 · Cited by 895
Retrograde heart perfusion: The Langendorff technique of isolated heart perfusion
Bell, R. M., Mocanu, M. M., & Yellon, D. M. (2011) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2011.02.018 · Cited by 505
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Quantum Noise Limited and Entanglement-Assisted Magnetometry
Wasilewski, W., Jensen, K., Krauter, H., Renema, J. J., Balabas, M. V., & Polzik, E. S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.133601 · Cited by 434
Self-citationSpin-exchange-relaxation-free magnetometry with Cs vapor
Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V. (2008) · Physical Review A · doi:10.1103/physreva.77.033408 · Cited by 399
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“This can lead to a clinical decision for medical intervention, even before birth [4].”
BackgroundCriticality-Enhanced Quantum Sensing via Continuous Measurement
Ilias, T., Yang, D., Huelga, S. F., & Plenio, M. B. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010354 · Cited by 208
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
“Most MEMS vapor cells are filled with buffer gas, although antirelaxation-coated cells may offer advantages for biological applications where elevated-temperature operation is problematic [24, 155].”
BackgroundMillimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Metadata
- Authors
- Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S.
- Affiliations
- University of Copenhagen (DK)
- Corresponding author
- Jensen, Kasper
- ORCID
- Venue
- Scientific Reports
- Published
- 2018-11-01
- Volume
- 8
- Issue
- 1
- Pages
- 16218-16218
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6212485
- OpenAlex
- W2810392889
- Cited by
- 79
- References
- 35
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 12 · 2023: 17 · 2022: 9 · 2021: 14 · 2020: 8 · 2019: 7
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Innovationsfonden
- Army Research Office (W911NF, W911NF-11-0235, W911NF-11)
- Army Research Laboratory (W911NF)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- magnetocardiography, optically pumped magnetometers, room-temperature magnetometry, isolated guinea pig heart, cardiac magnetic field, P wave, QRS complex, T wave, QT interval, RR interval, drug-induced QT prolongation, cardiac electrophysiology
- MeSH terms
- Algorithms, Animals, Electrocardiography, Guinea Pigs, Heart, Humans, Models, Biological, Temperature, Electrophysiologic Techniques, Cardiac, Magnetocardiography, Magnetometry, Optical Imaging, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer. https://app.cochat.ai/papers/10.1038/s41598-018-34535-z
- The paper
- Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018). Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer. Scientific Reports. https://doi.org/10.1038/s41598-018-34535-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.