Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 256

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Predictors of Poor Outcomes After Transcatheter Aortic Valve Replacement: Results From the PARTNER (Placement of Aortic Transcatheter Valve) Trial

Open access
Arnold, Suzanne V., Reynolds, Matthew R., Lei, Yang, Magnuson, Elizabeth A., Kirtane, Ajay J., Kodali, Susheel K., Zajarias, Alan, Thourani, Vinod H., Green, Philip, Rodés-Cabau, Josep, Beohar, Nirat, Mack, Michael J., Leon, Martin B., Cohen, David J. · 2014 · Circulation

Abstract

Background—: Transcatheter aortic valve replacement (TAVR) is a less invasive option for treatment of high-risk patients with severe aortic stenosis. We sought to identify patients at high risk for poor outcome after TAVR using a novel definition of outcome that integrates quality of life with mortality. Methods and Results—: Among 2137 patients who underwent TAVR in the PARTNER (Placement of Aortic Transcatheter Valve) trial or its associated continued access registry, quality of life was assessed with the Kansas City Cardiomyopathy Questionnaire–Overall Summary Scale (KCCQ-OS; range 0–100, where a higher score equates to a better quality of life) at baseline and at 1, 6, and 12 months after TAVR. A poor 6-month outcome (defined as death, KCCQ-OS score <45, or ≥10-point decrease in KCCQ-OS score compared with baseline) occurred in 704 patients (33%). Using a split-sample design, we developed a multivariable model to identify a parsimonious set of covariates to identify patients at high risk for poor outcome. The model demonstrated moderate discrimination ( c -index=0.66) and good calibration with the observed data, performed similarly in the separate validation cohort ( c -index=0.64), and identified 211 patients (10% of the population) with a ≥50% likelihood of a poor outcome after TAVR. A second model that explored predictors of poor outcome at 1 year identified 1102 patients (52%) with ≥50% likelihood and 178 (8%) with ≥70% likelihood of a poor 1-year outcome after TAVR. Conclusions—: Using a large, multicenter cohort, we have developed and validated predictive models that can identify patients at high risk for a poor outcome after TAVR. Although model discrimination was moderate, these models may help guide treatment choices and offer patients realistic expectations of outcomes based on their presenting characteristics. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.007477

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 256

Metadata

Authors
Arnold, S. V., Reynolds, M. R., Lei, Y., Magnuson, E. A., Kirtane, A. J., Kodali, S. K., Zajarias, A., Thourani, V. H., Green, P., Rodés-Cabau, J., Beohar, N., Mack, M. J., Leon, M. B., & Cohen, D. J.
Venue
Circulation
Published
2014-06-24
Volume
129
Issue
25
Pages
2682-2690
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2885836800
Cited by
256
References
31
FWCI
18.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.