Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Improved Survival After Out-of-Hospital Cardiac Arrest and Use of Automated External Defibrillators

Open access
Blom, Marieke T., Beesems, Stefanie G., Homma, Petronella C.M., Zijlstra, Jolande A., Hulleman, Michiel, van Hoeijen, Daniel A., Bardai, Abdennasser, Tijssen, Jan G.P., Tan, Hanno L., Koster, Rudolph W.·2014·Circulation

Abstract

Background—: In recent years, a wider use of automated external defibrillators (AEDs) to treat out-of-hospital cardiac arrest was advocated in The Netherlands. We aimed to establish whether survival with favorable neurologic outcome after out-of-hospital cardiac arrest has significantly increased, and, if so, whether this is attributable to AED use. Methods and Results—: We performed a population-based cohort study, including patients with out-of-hospital cardiac arrest from cardiac causes between 2006 and 2012, excluding emergency medical service–witnessed arrests. We determined survival status at each stage (to emergency department, to admission, and to discharge) and examined temporal trends using logistic regression analysis with year of resuscitation as an independent variable. By adding each covariable subsequently to the regression model, we investigated their impact on the odds ratio of year of resuscitation. Analyses were performed according to initial rhythm (shockable versus nonshockable) and AED use. Rates of survival with favorable neurologic outcome after out-of-hospital cardiac arrest increased significantly (N=6133, 16.2% to 19.7%; P for trend=0.021), although solely in patients presenting with a shockable initial rhythm (N=2823; 29.1% to 41.4%; P for trend<0.001). In this group, survival increased at each stage but was strongest in the prehospital phase (odds ratio, 1.11 [95% CI, 1.06–1.16]). Rates of AED use almost tripled during the study period (21.4% to 59.3%; P for trend <0.001), thereby decreasing time from emergency call to defibrillation-device connection (median, 9.9 to 8.0 minutes; P <0.001). AED use statistically explained increased survival with favorable neurologic outcome by decreasing the odds ratio of year of resuscitation to a nonsignificant 1.04. Conclusions—: Increased AED use is associated with increased survival in patients with a shockable initial rhythm. We recommend continuous efforts to introduce or extend AED programs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.114.010905

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Research works printed but not linked: 2

  1. 10.1016/S0196-0644(95)70356-X · doi:10.1016/s0196-0644(95)70356-x
  2. 10.1016/j.resuscitation.2006.12.014 · doi:10.1016/j.resuscitation.2006.12.014

Cited by

See all 362

Metadata

Authors
Blom, M. T., Beesems, S. G., Homma, P. C. M., Zijlstra, J. A., Hulleman, M., van Hoeijen, D. A., Bardai, A., Tijssen, J. G. P., Tan, H. L., & Koster, R. W.
Venue
Circulation
Published
2014-11-18
Volume
130
Issue
21
Pages
1868-1875
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2101027297
Cited by
362
References
25
FWCI
36.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Survival After Out-of-Hospital Cardiac Arrest and Use of Automated External Defibrillators. https://app.cochat.ai/papers/10.1161/circulationaha.114.010905
The paper
Blom, M. T., Beesems, S. G., Homma, P. C. M., Zijlstra, J. A., Hulleman, M., van Hoeijen, D. A., Bardai, A., Tijssen, J. G. P., Tan, H. L., & Koster, R. W. (2014). Improved Survival After Out-of-Hospital Cardiac Arrest and Use of Automated External Defibrillators. Circulation. https://doi.org/10.1161/circulationaha.114.010905

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.