The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Improving the Diagnosis of Infective Endocarditis in Prosthetic Valves and Intracardiac Devices With 18 F-Fluordeoxyglucose Positron Emission Tomography/Computed Tomography Angiography: Initial Results at an Infective Endocarditis Referral Center
Abstract
Background—: The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography (PET)/computed tomography (CT) and 18 F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit. Methods and Results—: Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% ( P <0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT ( P =0.006) or echocardiography ( P <0.001). Conclusions—: 18 F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pencina, M. J., D' Agostino, R. B., D' Agostino, R. B., & Vasan, R. S. (2008) · Statistics in Medicine · doi:10.1002/sim.2929 · Cited by 6,493 · cited 1×
“Possible 50 (54) 8 (9) 12 (13) 17 (18) 5 (5)”
Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009)
Endorsed by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and by the International Society of Chemotherapy (ISC) for Infection and Cancer, Habib, G., Hoen, B., Tornos, P., Thuny, F., Prendergast, B., Vilacosta, I., Moreillon, P., de Jesus Antunes, M., Thilen, U., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp285 · Cited by 2,014
Self-citationRecommendations for the practice of echocardiography in infective endocarditis
Habib, G., (France), Badano, L., (Italy), Tribouilloy, C., (France), Vilacosta, I., (Spain), Zamorano, J. L., (Spain), et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq004 · Cited by 621
EANM/SNMMI Guideline for18F-FDG Use in Inflammation and Infection
Jamar, F., Buscombe, J., Chiti, A., Christian, P. E., Delbeke, D., Donohoe, K. J., Israel, O., Martin-Comin, J., & Signore, A. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.112524 · Cited by 577
Positron Emission Tomography/Computed Tomography for Diagnosis of Prosthetic Valve Endocarditis
Saby, L., Laas, O., Habib, G., Cammilleri, S., Mancini, J., Tessonnier, L., Casalta, J.-P., Gouriet, F., Riberi, A., Avierinos, J.-F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.092 · Cited by 503
Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Rafique, A., Farkouh, M., Fuster, V., & Fayad, Z. A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.05.024 · Cited by 423
Multislice Computed Tomography in Infective Endocarditis
Feuchtner, G. M., Stolzmann, P., Dichtl, W., Schertler, T., Bonatti, J., Scheffel, H., Mueller, S., Plass, A., Mueller, L., Bartel, T., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.01.077 · Cited by 422
Sarrazin, J.-F., Philippon, F., Tessier, M., Guimond, J., Molin, F., Champagne, J., Nault, I., Blier, L., Nadeau, M., Charbonneau, L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.059 · Cited by 285
Infection imaging using whole-body FDG-PET
Stumpe, K. D. M., Dazzi, H., Schaffner, A., & von Schulthess, G. K. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000277 · Cited by 266
Rouzet, F., Chequer, R., Benali, K., Lepage, L., Ghodbane, W., Duval, X., Iung, B., Vahanian, A., Le Guludec, D., & Hyafil, F. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.141895 · Cited by 230
Cited by
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
Self-citation2024 ESC Guidelines for the management of peripheral arterial and aortic diseases
Mazzolai, L., Teixido-Tura, G., Lanzi, S., Boc, V., Bossone, E., Brodmann, M., Bura-Rivière, A., De Backer, J., Deglise, S., Della Corte, A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae179 · Cited by 993
Habib, G., Erba, P. A., Iung, B., Donal, E., Cosyns, B., Laroche, C., Popescu, B. A., Prendergast, B., Tornos, P., Sadeghpour, A., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz620 · Cited by 911
Self-citationChallenges in Infective Endocarditis
Cahill, T. J., Baddour, L. M., Habib, G., Hoen, B., Salaun, E., Pettersson, G. B., Schäfers, H. J., & Prendergast, B. D. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.066 · Cited by 715
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Changing Landscape of Congenital Heart Disease
Bouma, B. J., & Mulder, B. J. M. (2017) · Circulation Research · doi:10.1161/circresaha.116.309302 · Cited by 437
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Pettersson, G. B., Coselli, J. S., Pettersson, G. B., Coselli, J. S., Hussain, S. T., Griffin, B., Blackstone, E. H., Gordon, S. M., LeMaire, S. A., & Woc-Colburn, L. E. (2017) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2016.09.093 · Cited by 410
Holland, T. L., Baddour, L. M., Bayer, A. S., Hoen, B., Miro, J. M., & Fowler, V. G. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.59 · Cited by 406
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz296 · Cited by 318
Diagnostic value of imaging in infective endocarditis: a systematic review
Gomes, A., Glaudemans, A. W. J. M., Touw, D. J., van Melle, J. P., Willems, T. P., Maass, A. H., Natour, E., Prakken, N. H. J., Borra, R. J. H., van Geel, P. P., et al. (2017) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(16)30141-4 · Cited by 277
Characterization of 18 F-Fluorodeoxyglucose Uptake Pattern in Noninfected Prosthetic Heart Valves
Mathieu, C., Mikaïl, N., Benali, K., Iung, B., Duval, X., Nataf, P., Jondeau, G., Hyafil, F., Le Guludec, D., & Rouzet, F. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.005585 · Cited by 102
Targeting Cardiovascular Implant Infection: Multimodality and Molecular Imaging
Sohns, J. M., Bavendiek, U., Ross, T. L., & Bengel, F. M. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.005376 · Cited by 24
Metadata
- Authors
- Pizzi, M. N., Roque, A., Fernández-Hidalgo, N., Cuéllar-Calabria, H., Ferreira-González, I., Gonzàlez-Alujas, M. T., Oristrell, G., Gracia-Sánchez, L., González, J. J., Rodríguez-Palomares, J., Galiñanes, M., Maisterra-Santos, O., Garcia-Dorado, D., Castell-Conesa, J., Almirante, B., Aguadé-Bruix, S., & Tornos, P.
- Venue
- Circulation
- Published
- 2015-09-22
- Volume
- 132
- Issue
- 12
- Pages
- 1113-1126
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2176021874
- Cited by
- 401
- References
- 26
- FWCI
- 27.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.