Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators: Long-Term Results of a Prospective Multinational Registry
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
U ntil 2015, consensus statements 1,2 advised against sports participation more vigorous than golf for patients with implantable cardioverter-defibrillators (ICDs) because of the postulated risks of death caused by failure to defibrillate, injury resulting from arrhythmia-related syncope or shock, or device damage.The multinational, prospective, observational ICD Sports Safety Registry quantified risks associated with sports participation for athletes receiving ICDs on the basis of standard criteria.Initial results (2013 3 ) demonstrated no death, failure to defibrillate, or injury resulting from arrhythmia or shock during sports.On the basis of these data, the 2015 eligibility and disqualification recommendations for competitive athletes with cardiovascular disease 4 now state that competitive sports may be considered for athletes with ICDs.This report describes 4-year follow-up of the completed registry.3 Methods are as reported previously.3 The Yale University Human Investigation Committee approved the study.All participants gave written informed consent.Among 440 participants, 393 in organized sports and 47 in high-risk sports, the most common diagnoses were long-QT syndrome (n=87, 20%), hypertrophic cardiomyopathy (n=75, 17%), and arrhythmogenic right ventricular cardiomyopathy (n=55, 13%).Of 201 subjects with a preimplantation history of ventricular fibrillation (VF) or tachycardia (VT), 61 (30%) had VT/VF during sports.At enrollment, median time since implantation was 26 months (interquartile range, 11-59 months), with 126 subjects (29%) enrolled within 1 year of implantation.The most common organized sports were running, basketball, and soccer; the most common dangerous sport was skiing.Seventy-seven subjects (18%) engaged in varsity/junior varsity/ traveling team competition, (highly competitive subgroup).Seventy-two postcollege athletes (16%) participated at a national/international level.Median follow-up was 44 months (interquartile range, 30-48 months), totaling 1446 person-years.Thirty-seven participants did not complete the study: 20 were lost to follow-up (all confirmed alive), 5 withdrew, 6 developed worsening cardiac/ medical conditions, 4 had the ICD removed, and 2 died (neither death was sports related, as reported previously 3 ).There were no tachyarrhythmic deaths or externally resuscitated tachyarrhythmias during or after sports participation or injury resulting from arrhythmia-related syncope or shock during sports.The 95% confidence interval for the occurrence of adverse event based on 376 participants followed up at least 2 years was 0% to 0.9% and based on 167 participants followed up at least 4 years was 0% to 2.2%.The numbers and rhythms of shocks received for the overall group and the highly competitive subgroup are shown in the Table .Forty-six (10%) received appropriate shocks (for VT/VF) during competition or practice, a rate of 3 per 100 person-years (identical to the initial report 3 ).More participants received shocks during competition/ practice or physical activity than rest (20% versus 10%; P<0.0001), but the proportion receiving a shock during competition/practice was similar to the proportion receiving a shock during other physical activity (12% versus 10%; P=0.56).Similarly, the
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Shared decision making — The pinnacle of patient-centered care
Barry, M. J., & Edgman-Levitan, S. (2012) · New England Journal of Medicine · doi:10.1056/nejmp1109283 · Cited by 3,433
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Sudden Death in Young Competitive Athletes: Clinical, Demographic, and Pathological Profiles
Maron, B. J. (1996) · JAMA · doi:10.1001/jama.1996.03540030033028 · Cited by 1,693
Self-citationDoes sports activity enhance the risk of sudden death in adolescents and young adults?
Corrado, D., Basso, C., Rizzoli, G., Schiavon, M., & Thiene, G. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.03.002 · Cited by 1,311
Triggering of Sudden Death from Cardiac Causes by Vigorous Exertion
Albert, C. M., Mittleman, M. A., Chae, C. U., Lee, I.-M., Hennekens, C. H., & Manson, J. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011093431902 · Cited by 1,020
Pelliccia, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi325 · Cited by 983
Maron, B. J., & Zipes, D. P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.006 · Cited by 616
Self-citationKirchhof, P., Fabritz, L., Zwiener, M., Witt, H., Schäfers, M., Zellerhoff, S., Paul, M., Athai, T., Hiller, K.-H., Baba, H. A., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.624502 · Cited by 429
Heidbüchel, H. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00282-3 · Cited by 395
Self-citation
Cited by
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2020 ESC guidelines on sports cardiology and exercise in patients with cardiovascular disease
Pelliccia, A., Sharma, S., Gati, S., Bäck, M., Börjesson, M., Caselli, S., Collet, J.-P., Corrado, D., Drezner, J. A., Halle, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa605 · Cited by 1,958
Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., Kantor, P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.044 · Cited by 994
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Metadata
- Authors
- Lampert, R., Olshansky, B., Heidbuchel, H., Lawless, C., Saarel, E., Ackerman, M., Calkins, H., Estes, N. A. M., Link, M. S., Maron, B. J., Marcus, F., Scheinman, M., Wilkoff, B. L., Zipes, D. P., Berul, C. I., Cheng, A., Jordaens, L., Law, I., Loomis, M., Willems, R., Barth, C., Broos, K., Brandt, C., Dziura, J., Li, F., Simone, L., Vandenberghe, K., & Cannom, D.
- Venue
- Circulation
- Published
- 2017-06-06
- Volume
- 135
- Issue
- 23
- Pages
- 2310-2312
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3155397230
- Cited by
- 156
- References
- 20
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators: Long-Term Results of a Prospective Multinational Registry. https://app.cochat.ai/papers/10.1161/circulationaha.117.027828
- The paper
- Lampert, R., Olshansky, B., Heidbuchel, H., Lawless, C., Saarel, E., Ackerman, M., Calkins, H., Estes, N. A. M., Link, M. S., Maron, B. J., Marcus, F., Scheinman, M., Wilkoff, B. L., Zipes, D. P., Berul, C. I., Cheng, A., Jordaens, L., Law, I., Loomis, M., . . . Cannom, D. (2017). Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators: Long-Term Results of a Prospective Multinational Registry. Circulation. https://doi.org/10.1161/circulationaha.117.027828
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.