Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 249

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Subclinical Atrial Fibrillation in Older Patients

Open access
Healey, Jeff S., Alings, Marco, Ha, Andrew, Leong-Sit, Peter, Birnie, David H., de Graaf, Jacob J., Freericks, Michel, Verma, Atul, Wang, Jia, Leong, Darryl, Dokainish, Hisham, Philippon, Francois, Barake, Walid, McIntyre, William F., Simek, Kim, Hill, Michael D., Mehta, Shamir R., Carlson, Mark, Smeele, Frank, Pandey, A. Shekhar, Connolly, Stuart J. · 2017 · Circulation

Abstract

Background: Long-term continuous electrocardiographic monitoring shows a substantial prevalence of asymptomatic, subclinical atrial fibrillation (SCAF) in patients with pacemakers and patients with cryptogenic stroke. Whether SCAF is also common in other patients without these conditions is unknown. Methods: We implanted subcutaneous electrocardiographic monitors (St. Jude CONFIRM-AF) in patients ≥65 years of age attending cardiovascular or neurology outpatient clinics if they had no history of atrial fibrillation but had any of the following: CHA 2 DS 2 -VASc score of ≥2, sleep apnea, or body mass index >30 kg/m 2 . Eligibility also required either left atrial enlargement (≥4.4 cm or volume ≥58 mL) or increased (≥290 pg/mL) serum NT-proBNP (N-terminal pro–B-type natriuretic peptide). Patients were monitored for SCAF lasting ≥5 minutes. Results: Two hundred fifty-six patients were followed up for 16.3±3.8 months. Baseline age was 74±6 years; mean CHA 2 DS 2 -VASc score was 4.1±1.4; left atrial diameter averaged 4.7±0.8 cm; and 48% had a prior stroke, transient ischemic attack, or systemic embolism. SCAF ≥5 minutes was detected in 90 patients (detection rate, 34.4%/y; 95% confidence interval [CI], 27.7–42.3). Baseline predictors of SCAF were increased age (hazard ratio [HR] per decade, 1.55; 95% CI, 1.11–2.15), left atrial dimension (HR per centimeter diameter, 1.43; 95% CI, 1.09–1.86), and blood pressure (HR per 10 mm Hg, 0.87; 95% CI, 0.78–0.98), but not prior stroke. The rate of occurrence of SCAF in those with a history of stroke, systemic embolism, or transient ischemic attack was 39.4%/y versus 30.3%/y without ( P =0.32). The cumulative SCAF detection rate was higher (51.9%/y) in those with left atrial volume above the median value of 73.5 mL. Conclusions: SCAF is frequently detected by continuous electrocardiographic monitoring in older patients without a history of atrial fibrillation who are attending outpatient cardiology and neurology clinics. Its clinical significance is unclear. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01694394.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.117.028845

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 249

Metadata

Authors
Healey, J. S., Alings, M., Ha, A., Leong-Sit, P., Birnie, D. H., de Graaf, J. J., Freericks, M., Verma, A., Wang, J., Leong, D., Dokainish, H., Philippon, F., Barake, W., McIntyre, W. F., Simek, K., Hill, M. D., Mehta, S. R., Carlson, M., Smeele, F., Pandey, A. S., & Connolly, S. J.
Venue
Circulation
Published
2017-10-03
Volume
136
Issue
14
Pages
1276-1283
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2743797071
Cited by
249
References
7
FWCI
20.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.