The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Use of Intracardiac Echocardiography in Interventional Cardiology: Working With the Anatomy Rather Than Fighting It
Abstract
The indications for catheter-based structural and electrophysiological procedures have recently expanded to more complex scenarios, in which an accurate definition of the variable individual cardiac anatomy is key to obtain optimal results. Intracardiac echocardiography (ICE) is a unique imaging modality able to provide high-resolution real-time visualization of cardiac structures, continuous monitoring of catheter location within the heart, and early recognition of procedural complications, such as pericardial effusion or thrombus formation. Additional benefits are excellent patient tolerance, reduction of fluoroscopy time, and lack of need for general anesthesia or a second operator. For these reasons, ICE has largely replaced transesophageal echocardiography as ideal imaging modality for guiding certain procedures, such as atrial septal defect closure and catheter ablation of cardiac arrhythmias, and has an emerging role in others, including mitral valvuloplasty, transcatheter aortic valve replacement, and left atrial appendage closure. In electrophysiology procedures, ICE allows integration of real-time images with electroanatomic maps; it has a role in assessment of arrhythmogenic substrate, and it is particularly useful for mapping structures that are not visualized by fluoroscopy, such as the interatrial or interventricular septum, papillary muscles, and intracavitary muscular ridges. Most recently, a three-dimensional (3D) volumetric ICE system has also been developed, with potential for greater anatomic information and a promising role in structural interventions. In this state-of-the-art review, we provide guidance on how to conduct a comprehensive ICE survey and summarize the main applications of ICE in a variety of structural and electrophysiology procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Holmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Du, Z.-D., Hijazi, Z. M., Kleinman, C. S., Silverman, N. H., & Larntz, K. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01862-4 · Cited by 961
Silvestry, F. E., Cohen, M. S., Armsby, L. B., Burkule, N. J., Fleishman, C. E., Hijazi, Z. M., Lang, R. M., Rome, J. J., & Wang, Y. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.05.015 · Cited by 604
Self-citationMarrouche, N. F., Martin, D. O., Wazni, O., Gillinov, A. M., Klein, A., Bhargava, M., Saad, E., Bash, D., Yamada, H., Jaber, W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070541.83326.15 · Cited by 512
Kato, R., Lickfett, L., Meininger, G., Dickfeld, T., Wu, R., Juang, G., Angkeow, P., LaCorte, J., Bluemke, D., Berger, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000061951.81767.4e · Cited by 492
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332
Long-Term Outcomes After Transcatheter Aortic Valve Implantation
Rodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Osten, M., Feindel, C. M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.960 · Cited by 298
Callans, D. J., Ren, J., Michele, J. J., Marchlinski, F. E., & Dillon, S. M. (1999) · Circulation · doi:10.1161/01.cir.100.16.1744 · Cited by 297
Self-citationRen, J.-F., Marchlinski, F. E., & Callans, D. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.031 · Cited by 251
Self-citationBerger, F., Ewert, P., Boöjrnstad, P. G., Dähnert, I., Krings, G., Brilla-Austenat, I., Vogel, M., & Lange, P. E. (1999) · Cardiology in the Young · doi:10.1017/s1047951100005369 · Cited by 211
Daoud, E. G., KALBFLETSCH, S. J., & Hummel, J. D. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00683.x · Cited by 150
Intracardiac Echocardiography During Interventional and Electrophysiological Cardiac Catheterization
Hijazi, Z. M., Shivkumar, K., & Sahn, D. J. (2009) · Circulation · doi:10.1161/circulationaha.107.753046 · Cited by 144
Yeh, D. T., Oralkan, Ö., Wygant, I. O., O’Donnell, M., & Khuri-Yakub, B. T. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1642519 · Cited by 142
Santangeli, P., Biase, L. D., Burkhardt, J. D., Horton, R., Sánchez, J., BAILEY, S. M., ZAGRODZKY, J. D., Lakkireddy, D., Bai, R., Mohanty, P. K., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.06.023 · Cited by 129
Fluoroless Catheter Ablation of Cardiac Arrhythmias: A 5‐Year Experience
Razminia, M., WILLOUGHBY, M. C., Demo, H. N., Keshmiri, H., Wang, T., D’Silva, O., Zheutlin, T. A., JIBAWI, H., Okhumale, P. I., & Kehoe, R. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13038 · Cited by 119
Periprocedural Intracardiac Echocardiography for Left Atrial Appendage Closure
Berti, S. L., Paradossi, U., Meucci, F., Trianni, G., Tzikas, A., Rezzaghi, M., Stolkova, M., Palmieri, C., Mori, F., & Santoro, G. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.04.014 · Cited by 118
Lakkireddy, D., RANGISETTY, U., Prasad, S. K., Verma, A., Biria, M., Berenbom, L., Pimentel, R., Emert, M. P., Rosamond, T. L., Fahmy, T. S. E., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01249.x · Cited by 94
Ren, J., Marchlinski, F. E., Callans, D. J., & Zado, E. S. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.01076.x · Cited by 89
Self-citationMorton, J. B., Sanders, P., Davidson, N. C., SPARKS, P. B., Vohra, J. K., & Kalman, J. M. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02152.x · Cited by 78
Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement
Bartel, T., Bonaros, N. E., Müller, L. C., Friedrich, G. J., Grimm, M. F., Velik‐Salchner, C., Feuchtner, G. M., Pedross, F., & Müller, S. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.04.009 · Cited by 77
Anselmino, M., Blandino, A., Beninati, S., Rovera, C., Boffano, C., Belletti, M., Caponi, D., Scaglione, M., Cesarani, F., & Gaïta, F. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01853.x · Cited by 71
Schmidt, M. U., Daccarett, M., Marschang, H., Ritscher, G., Turschner, O., Brachmann, J., & Rittger, H. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01796.x · Cited by 61
Gami, A. S., Edwards, W. D., Lachman, N., Friedman, P. A., Talreja, D., Munger, T. M., Hammill, S. C., Packer, D. L., & Asirvatham, S. J. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01607.x · Cited by 57
Nölker, G., Heintze, J., Gutleben, K., Muntean, B. G., Pütz, V., Yalda, A., Vogt, J., & Horstkotte, D. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01813.x · Cited by 50
Silvestry, F. E., Kadakia, M. B., Willhide, J., & Herrmann, H. C. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.04.022 · Cited by 40
Self-citationBartel, T., Edris, A., Velik‐Salchner, C., & Müller, S. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev280 · Cited by 38
Wadehra, V., Buxton, A. E., Antoniadis, A. P., McCready, J. W., Redpath, C. J., Segal, O. R., Rowland, E., LOWE, M. D., Lambiase, P. D., & CHOW, A. W. C. (2011) · EP Europace · doi:10.1093/europace/eur155 · Cited by 35
Randomized Trial of Intracardiac Echocardiography During Cavotricuspid Isthmus Ablation
Bencsik, G., Pap, R., Makai, A., Klausz, G., Chadaide, S., TRAYKOV, V. B., Forster, T., & Sághy, L. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02331.x · Cited by 29
Electroanatomical mapping systems and intracardiac echo integration for guided endomyocardial biopsy
Casella, M., Russo, A. D., Vettor, G., Lumia, G., Catto, V., Sommariva, E., Ribatti, V., Biagioli, V., Tundo, F., Carbucicchio, C., et al. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1351875 · Cited by 28
Saji, M., Rossi, A. M., Ailawadi, G., Dent, J., Ragosta, M., & Lim, D. S. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25981 · Cited by 24
Real-time three-dimensional intracardiac echocardiography: an early single-center experience.
Maini, B. S. (2015) · PubMed · Cited by 10
Cited by
Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K., & Keshavarz-Motamed, Z. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3142058 · Cited by 89
Metadata
- Authors
- Enriquez, A., Saenz, L. C., Rosso, R., Silvestry, F. E., Callans, D., Marchlinski, F. E., & Garcia, F.
- Venue
- Circulation
- Published
- 2018-05-22
- Volume
- 137
- Issue
- 21
- Pages
- 2278-2294
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2890938642
- Cited by
- 262
- References
- 33
- FWCI
- 15.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.