Association Between Early Hyperoxia Exposure After Resuscitation From Cardiac Arrest and Neurological Disability: Prospective Multicenter Protocol-Directed Cohort Study

Roberts, Brian W., Kilgannon, J. Hope, Hunter, Benton R., Puskarich, Michael A., Pierce, Lisa, Donnino, Michael, Leary, Marion, Kline, Jeffrey A., Jones, Alan E., Shapiro, Nathan I., Abella, Benjamin S., Trzeciak, Stephen · 2018 · Circulation

Abstract

Background: Studies examining the association between hyperoxia exposure after resuscitation from cardiac arrest and clinical outcomes have reported conflicting results. Our objective was to test the hypothesis that early postresuscitation hyperoxia is associated with poor neurological outcome. Methods: This was a multicenter prospective cohort study. We included adult patients with cardiac arrest who were mechanically ventilated and received targeted temperature management after return of spontaneous circulation. We excluded patients with cardiac arrest caused by trauma or sepsis. Per protocol, partial pressure of arterial oxygen (Pa o 2 ) was measured at 1 and 6 hours after return of spontaneous circulation. Hyperoxia was defined as a Pa o 2 >300 mm Hg during the initial 6 hours after return of spontaneous circulation. The primary outcome was poor neurological function at hospital discharge, defined as a modified Rankin Scale score >3. Multivariable generalized linear regression with a log link was used to test the association between Pa o 2 and poor neurological outcome. To assess whether there was an association between other supranormal Pa o 2 levels and poor neurological outcome, we used other Pa o 2 cut points to define hyperoxia (ie, 100, 150, 200, 250, 350, 400 mm Hg). Results: Of the 280 patients included, 105 (38%) had exposure to hyperoxia. Poor neurological function at hospital discharge occurred in 70% of patients in the entire cohort and in 77% versus 65% among patients with versus without exposure to hyperoxia respectively (absolute risk difference, 12%; 95% confidence interval, 1–23). Hyperoxia was independently associated with poor neurological function (relative risk, 1.23; 95% confidence interval, 1.11–1.35). On multivariable analysis, a 1-hour-longer duration of hyperoxia exposure was associated with a 3% increase in risk of poor neurological outcome (relative risk, 1.03; 95% confidence interval, 1.02–1.05). We found that the association with poor neurological outcome began at ≥300 mm Hg. Conclusions: Early hyperoxia exposure after resuscitation from cardiac arrest was independently associated with poor neurological function at hospital discharge.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.117.032054

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Roberts, B. W., Kilgannon, J. H., Hunter, B. R., Puskarich, M. A., Pierce, L., Donnino, M., Leary, M., Kline, J. A., Jones, A. E., Shapiro, N. I., Abella, B. S., & Trzeciak, S.
Venue
Circulation
Published
2018-05-15
Volume
137
Issue
20
Pages
2114-2124
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2979851589
Cited by
206
References
5
FWCI
30.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.