Mobile Phone Detection of Atrial Fibrillation With Mechanocardiography: The MODE-AF Study (Mobile Phone Detection of Atrial Fibrillation)
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
atrial fibrillation ◼ mobile health B ecause of the frequent asymptomatic presentation of atrial fibrillation (AF), stroke is too often its first manifestation. 1 For effective stroke prevention, timely diagnosis of AF is crucial.Mobile devices are becoming ubiquitous, providing significant possibilities for screening applications.In mechanocardiography, mechanical cardiac activity is recorded with accelerometers and gyroscopes, standard components of modern smartphones.2 In our previous proof-of-concept study, smartphone mechanocardiography demonstrated 94% sensitivity and 100% specificity for detecting AF among 39 subjects.2 Here, we validate smartphone mechanocardiography detection of AF against visual interpretation of telemetry electrocardiographic recordings in hospitalized patients.For the present case-control study, 150 consecutive patients in AF and 150 ageand sex-matched patients in sinus rhythm (SR) were enrolled from the cardiology and internal medicine wards of Turku University Hospital, Finland, between April and September 2017.After informed consent was obtained, a 3-minute mechanocardiography recording was acquired from each subject with a Sony Xperia smartphone placed on the sternum, and a simultaneously obtained 5-lead telemetry electrocardiography (Philips IntelliVue MX40) recording was used as the comparison method to assess rhythm and the number of supraventricular and ventricular extrasystoles.Electrocardiographic rhythm classifications were confirmed by 2 independent cardiologists, and a third cardiologist made the final decision if interpretations diverged.In addition, physical measurements were recorded, and electronic patient records were searched for the subjects' clinical history and investigations conducted during the index hospitalization.The institutional ethics review board approved the study protocol.The mechanocardiography recordings were analyzed with an algorithm developed beforehand by investigators blinded to the underlying rhythm.The data were first preprocessed by applying a band-pass filter to remove signal noise and bias.The algorithm then examined each of the 6 data axes of the signal with 5-second autocorrelation windows to find evidence of constant beat-to-beat intervals.Finally, for classification as AF or SR, the share of signal segments with regularity was determined.A visual presentation of mechanocardiography data is shown in the Figure.The mean age of all subjects was 74.8 years (95% confidence interval [CI], 73.7-75.9),and 132 (44.0%) were female.The mechanocardiography algorithm correctly classified AF in 143 of 150 cases and SR in 144 of 150 controls.Altogether, 4 of the 6 cases in SR misclassified as AF had marked sinus arrhythmia, whereas no
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chan, P.-H., Wong, C.-K., Pun, L., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2017) · Circulation · doi:10.1161/circulationaha.116.024439 · Cited by 79
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 234
Kaisti, M., Panula, T., Leppänen, J., Punkkinen, R., Jafari Tadi, M., Vasankari, T., Jaakkola, S., Kiviniemi, T., Airaksinen, J., Kostiainen, P., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0117-x · Cited by 164
“photoplethysmography and mechanocardiography-based methods.(47,48) We envision that using the presented approach a new class of pressure sensors could be harnessed into a broad range of home monitoring solutions either as a stand-alone solution or integrated with other sensing modalities in the future.”
MethodSelf-citationMobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
“0%.(35,41) The diagnostic accuracy of smartbands and smartwatches was variable among studies depending on the different algorithms utilized, populations studied, and the testing conditions (most of the good quality data will be acquired when subjects are sleeping or sitting still).”
BackgroundVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Metadata
- Authors
- Jaakkola, J., Jaakkola, S., Lahdenoja, O., Hurnanen, T., Koivisto, T., Pänkäälä, M., Knuutila, T., Kiviniemi, T. O., Vasankari, T., & Airaksinen, K. E. J.
- Venue
- Circulation
- Published
- 2018-04-03
- Volume
- 137
- Issue
- 14
- Pages
- 1524-1527
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2791249085
- Cited by
- 66
- References
- 1
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mobile Phone Detection of Atrial Fibrillation With Mechanocardiography: The MODE-AF Study (Mobile Phone Detection of Atrial Fibrillation). https://app.cochat.ai/papers/10.1161/circulationaha.117.032804
- The paper
- Jaakkola, J., Jaakkola, S., Lahdenoja, O., Hurnanen, T., Koivisto, T., Pänkäälä, M., Knuutila, T., Kiviniemi, T. O., Vasankari, T., & Airaksinen, K. E. J. (2018). Mobile Phone Detection of Atrial Fibrillation With Mechanocardiography: The MODE-AF Study (Mobile Phone Detection of Atrial Fibrillation). Circulation. https://doi.org/10.1161/circulationaha.117.032804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.