Abstract
Ventricular assist device has rapidly emerged as a durable and safe therapy for end-stage heart failure patients with >22 000 implantations to date. Though originally conceived for bridge-to-transplant indication, significant advancements in medical management as well as technology with arrivals of newer generation devices have improved patient outcomes, leading to increasing use as destination therapy. Despite such improvement, however, the burden of adverse events remains significant and defines the most pressing issue in the current state of ventricular assist device therapy. Eventual use of ventricular assist device technology as a comparable alternative to heart transplantation will ultimately rely on our ability to mitigate these risks. Therefore, this review article provides the narrative surrounding the rapid integration of this technology into the heart failure paradigm, specifically in the context of the most recent data on its outcomes and adverse event profiles. It describes ongoing investigations and general trends that may have significant implications for future improvements in device-related outcomes, as the field continues to grow as the epitome of synergy between advancements in engineering and clinical medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8807 · Cited by 3,304
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Roger, V. L. (2013) · Circulation Research · doi:10.1161/circresaha.113.300268 · Cited by 1,728
Feldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Unexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis
Starling, R. C., Moazami, N., Silvestry, S. C., Ewald, G., Rogers, J. G., Milano, C. A., Rame, J. E., Acker, M. A., Blackstone, E. H., Ehrlinger, J., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313385 · Cited by 786
Self-citationIntrapericardial Left Ventricular Assist Device for Advanced Heart Failure
Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1602954 · Cited by 758
Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure
Mehra, M. R., Goldstein, D. J., Uriel, N., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C., Walsh, M. N., Milano, C. A., Patel, C. B., Ewald, G. A., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1800866 · Cited by 722
Metadata
- Authors
- Han, J. J., Acker, M. A., & Atluri, P.
- Venue
- Circulation
- Published
- 2018-12-11
- Volume
- 138
- Issue
- 24
- Pages
- 2841-2851
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2903851611
- Cited by
- 201
- References
- 42
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine. https://app.cochat.ai/papers/10.1161/circulationaha.118.035566
- The paper
- Han, J. J., Acker, M. A., & Atluri, P. (2018). Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine. Circulation. https://doi.org/10.1161/circulationaha.118.035566
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.