Five-Year Clinical and Echocardiographic Outcomes From the NOTION Randomized Clinical Trial in Patients at Lower Surgical Risk

Open access
Thyregod, Hans Gustav Hørsted, Ihlemann, Nikolaj, Jørgensen, Troels Højsgaard, Nissen, Henrik, Kjeldsen, Bo Juel, Petursson, Petur, Chang, Yanping, Franzen, Olaf Walter, Engstrøm, Thomas, Clemmensen, Peter, Hansen, Peter Bo, Andersen, Lars Willy, Steinbruüchel, Daniel Andreas, Olsen, Peter Skov, Søndergaard, Lars · 2019 · Circulation

Abstract

Background: The NOTION trial (Nordic Aortic Valve Intervention) was designed to compare transcatheter aortic valve replacement (TAVR) with surgical aortic valve replacement (SAVR) in patients ≥70 years old with isolated severe aortic valve stenosis. Clinical and echocardiographic outcomes are presented after 5 years. Methods: Patients were enrolled at 3 Nordic centers and randomized 1:1 to TAVR using the self-expanding CoreValve prosthesis (n=145) or SAVR using any stented bioprostheses (n=135). The primary composite outcome was the rate of all-cause mortality, stroke, or myocardial infarction at 1 year defined according to Valve Academic Research Consortium-2 criteria. Results: Baseline characteristics were similar. The mean age was 79.1±4.8 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 3.0%±1.7%. After 5 years, there were no differences between TAVR and SAVR in the composite outcome (Kaplan-Meier estimates 38.0% versus 36.3%, log-rank test P =0.86) or any of its components. TAVR patients had larger prosthetic valve area (1.7 cm 2 versus 1.2 cm 2 , P <0.001) with a lower mean transprosthetic gradient (8.2 mm Hg versus 13.7 mm Hg, P <0.001), both unchanged over time. More TAVR patients had moderate/severe total aortic regurgitation (8.2% versus 0.0%, P <0.001) and a new pacemaker (43.7% versus 8.7%, P <0.001). Four patients had prosthetic reintervention and no difference was found for functional outcomes. Conclusions: These are currently the longest follow-up data comparing TAVR and SAVR in lower risk patients, demonstrating no statistical difference for major clinical outcomes 5 years after TAVR with a self-expanding prosthesis compared to SAVR. Higher rates of prosthetic regurgitation and pacemaker implantation were seen after TAVR. Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT01057173.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.036606

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 337

Metadata

Authors
Thyregod, H. G. H., Ihlemann, N., Jørgensen, T. H., Nissen, H., Kjeldsen, B. J., Petursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., Hansen, P. B., Andersen, L. W., Steinbruüchel, D. A., Olsen, P. S., & Søndergaard, L.
Venue
Circulation
Published
2019-06-11
Volume
139
Issue
24
Pages
2714-2723
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2981517894
Cited by
337
References
30
FWCI
31.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Five-Year Clinical and Echocardiographic Outcomes From the NOTION Randomized Clinical Trial in Patients at Lower Surgical Risk. https://app.cochat.ai/papers/10.1161/circulationaha.118.036606
The paper
Thyregod, H. G. H., Ihlemann, N., Jørgensen, T. H., Nissen, H., Kjeldsen, B. J., Petursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., Hansen, P. B., Andersen, L. W., Steinbruüchel, D. A., Olsen, P. S., & Søndergaard, L. (2019). Five-Year Clinical and Echocardiographic Outcomes From the NOTION Randomized Clinical Trial in Patients at Lower Surgical Risk. Circulation. https://doi.org/10.1161/circulationaha.118.036606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.