The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry
Open accessAbstract
Background: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. Methods: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. Results: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA 2 DS 2 -VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289–421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%–80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P =0.001). Acute major adverse events occurred in 1.9% of patients. Conclusions: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationMembrane Electroporation and Electropermeabilization: Mechanisms and Models
Kotnik, T., Rems, L., Tarek, M., & Miklavčič, D. (2019) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-052118-115451 · Cited by 813
Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
Reddy, V. Y., Neuzil, P., Koruth, J. S., Petru, J., Funosako, M., Cochet, H., Sediva, L., Chovanec, M., Dukkipati, S. R., & Jais, P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.04.021 · Cited by 700
Self-citationPulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Verma, A., Haines, D. E., Boersma, L. V., Sood, N., Natale, A., Marchlinski, F. E., Calkins, H., Sanders, P., Packer, D. L., Kuck, K.-H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.063988 · Cited by 613
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Reddy, V. Y., Dukkipati, S. R., Neuzil, P., Anic, A., Petru, J., Funasako, M., Cochet, H., Minami, K., Breskovic, T., Sikiric, I., et al. (2021) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.02.014 · Cited by 558
Self-citationPulsed Field Ablation in Patients With Persistent Atrial Fibrillation
Reddy, V. Y., Anic, A., Koruth, J., Petru, J., Funasako, M., Minami, K., Breskovic, T., Sikiric, I., Dukkipati, S. R., Kawamura, I., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.07.007 · Cited by 418
Self-citationEkanem, E., Reddy, V. Y., Schmidt, B., Reichlin, T., Neven, K. G. E. J., Metzner, A., Hansen, J., Blaauw, Y., Maury, P., Arentz, T., et al. (2022) · EP Europace · doi:10.1093/europace/euac050 · Cited by 382
Self-citation
Cited by
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
Reddy, V. Y., Gerstenfeld, E. P., Natale, A., Whang, W., Cuoco, F. A., Patel, C., Mountantonakis, S. E., Gibson, D. N., Harding, J. D., Ellis, C. R., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307291 · Cited by 970
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Self-citation
Metadata
- Authors
- Turagam, M. K., Neuzil, P., Schmidt, B., Reichlin, T., Neven, K., Metzner, A., Hansen, J., Blaauw, Y., Maury, P., Arentz, T., Sommer, P., Anic, A., Anselme, F., Boveda, S., Deneke, T., Willems, S., van der Voort, P., Tilz, R., Funasako, M., Scherr, D., Wakili, R., Steven, D., Kautzner, J., Vijgen, J., Jais, P., Petru, J., Chun, J., Roten, L., Füting, A., Lemoine, M. D., Ruwald, M., Mulder, B. A., Rollin, A., Lehrmann, H., Fink, T., Jurisic, Z., Chaumont, C., Adeliño, R., Nentwich, K., Gunawardene, M., Ouss, A., Heeger, C.-H., Manninger, M., Bohnen, J.-E., Sultan, A., Peichl, P., Koopman, P., Derval, N., Kueffer, T., Rahe, G., & Reddy, V. Y.
- Venue
- Circulation
- Published
- 2023-07-04
- Volume
- 148
- Issue
- 1
- Pages
- 35-46
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W4377010952
- Cited by
- 381
- References
- 17
- FWCI
- 67.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry. https://app.cochat.ai/papers/10.1161/circulationaha.123.064959
- The paper
- Turagam, M. K., Neuzil, P., Schmidt, B., Reichlin, T., Neven, K., Metzner, A., Hansen, J., Blaauw, Y., Maury, P., Arentz, T., Sommer, P., Anic, A., Anselme, F., Boveda, S., Deneke, T., Willems, S., van der Voort, P., Tilz, R., Funasako, M., . . . Reddy, V. Y. (2023). Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry. Circulation. https://doi.org/10.1161/circulationaha.123.064959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.