Cited by 5Cardiac Imaging and DiagnosticsLipoproteins and Cardiovascular HealthCoronary Interventions and Diagnostics

Effects of Real-Time Notification of AI-Detected Incidental Coronary Artery Calcium on Statin Prescription: The NOTIFY-PICTURE Trial

Open access
Dudum, Ramzi, Jain, Sneha S., Mastrodicasa, Domenico, Furst, Adam, Xu, Shiqin, Ngo, Summer, Eng, David, Khandwala, Nishith +6 more·2026·Circulation

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.125.078155

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Patient and clinician notifications based on AI-CAC results improved statin prescription and downstream lipid testing, statin persistence, LDL-C reduction and CAD evaluation.

    “Patient and clinician notifications based on AI-CAC results improved statin prescription and downstream lipid testing, statin persistence, low-density lipoprotein cholesterol (LDL-C) reduction and CAD evaluation.41–43”

    From Prognostication and clinical opportunities with AI for coronary artery calcium: a scoping review (2026) · cites this paper as [42]

    The NOTIFY-PICTURE results (page unavailable) report more statin prescriptions with notification than with usual care, particularly among patients without baseline ASCVD. The limitations state that statin adherence was not assessed and the trial lacked power to detect LDL-C changes; the paper does not report improved downstream lipid testing or CAD evaluation and says healthcare utilization did not increase. (LLM, conf=0.91)

    Experimental — accuracy not yet measured
  • Notification of patients and clinicians based on AI-CAC results increases cardiovascular preventive discussions, statin prescription rates and statin persistence.

    “Notification of patients and clinicians based on these results has been shown to increase cardiovascular preventive discussions, statin prescription rates and statin persistence.40–43”

    From Prognostication and clinical opportunities with AI for coronary artery calcium: a scoping review (2026) · cites this paper as [42]

    The NOTIFY-PICTURE results report higher statin prescription rates after notification (44% versus 9.8% with usual care), with the increase seen among patients without ASCVD but not those with ASCVD. The paper does not report an increase in cardiovascular preventive discussions, and its limitations state that statin adherence was not assessed; it therefore does not establish increased statin persistence. The supplied copy has no page numbers. (LLM, conf=0.90)

    Experimental — accuracy not yet measured
  • Three included studies employed an AI algorithm (Bunkerhill Health) in which co-investigator CPL holds equity interest.

    “Three included studies41–43 employed an AI algorithm (Bunkerhill Health) in which co-investigator CPL holds equity interest.”

    From Prognostication and clinical opportunities with AI for coronary artery calcium: a scoping review (2026) · cites this paper as [42]

    The NOTIFY-PICTURE methods passage (page not specified) says the trial screened CT scans using an AI algorithm, supporting its identification as one study that employed AI. Our copy does not name Bunkerhill Health as the algorithm’s provider or address CPL’s equity interest; this source also cannot establish how many studies the citing paper included. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dudum, R., Jain, S. S., Mastrodicasa, D., Furst, A., Xu, S., Ngo, S., Eng, D., Khandwala, N., Sousa, D., Chaudhari, A., Langlotz, C., Sandhu, A. T., Maron, D. J., & Rodriguez, F.
Affiliations
  • University of California, San Francisco (US)
  • Stanford Medicine (US)
  • University of Washington (US)
  • VA Palo Alto Health Care System (US)
  • Bunkerhill Health, Palo Alto, CA (D.E., N.K.).
  • Patient Representative, Hollister, CA (D.S.).
  • Department of Medicine, Division of Cardiovascular Medicine (S.S.J., A.F., S.X., S.N., A.T.S., D.J.M., F.R.), Stanford University, Stanford, CA.
Venue
Circulation
Published
2026-01-20
Volume
153
Issue
3
Pages
210-212
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W4416082460
Cited by
5
References
5
Citations by year
2026: 5
FWCI
2.88
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion)
Funders
  • Doris Duke Foundation (Grant #2022051)
  • HHS | NIH | National Heart, Lung, and Blood Institute (R01HL168188, R01HL167974, R01HL169345)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Surgery › Lipoproteins and Cardiovascular Health
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
Keywords
coronary artery calcium, incidental finding, artificial intelligence, real-time alerts, statin prescribing, statin therapy, cardiovascular risk

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review