The DOI matches its Crossref record.
Gas Exchange Detection of Exercise-Induced Right-to-Left Shunt in Patients With Primary Pulmonary Hypertension
Abstract
Background — Because of high pulmonary vascular resistance in patients with primary pulmonary hypertension (PPH), right atrial pressure may exceed left atrial pressure during exercise, resulting in a right-to-left shunt via a patent foramen ovale (PFO). This shunting would disturb arterial P co 2 and H + homeostasis if the pulmonary blood were not simultaneously hyperventilated to compensate for the high CO 2 and H + in the shunted blood. This article first hypothesizes and then describes unique changes in gas exchange when right-to-left exercise-induced shunting (EIS) occurs. Methods and Results — Retrospectively, the cardiopulmonary exercise tests of 71 PPH patients were studied. Criteria postulated to document hyperventilation of the pulmonary blood flow due to a right-to-left EIS were (1) an abrupt and sustained increase in end-tidal O 2 with a simultaneous sustained decrease in end-tidal CO 2 ; (2) an abrupt and sustained increase in the respiratory exchange ratio; and (3) usually, an associated decline in pulse oximetry saturation. Each patient was evaluated for a PFO with resting echocardiography. The investigators interpreting the gas exchange evidence of EIS were blinded to the echocardiographic readings. Forty-five percent of the patients had demonstrable EIS by gas exchange criteria. Almost all were also positive for a PFO by echocardiography. Using the resting echocardiograph as the reference, the sensitivity, specificity, positive and negative predictive values, and accuracy were all between 90% to 96%. Conclusions — Exercise-induced right-to-left shunting can be detected by noninvasive, cardiopulmonary exercise testing in patients with PPH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Guazzi, M., Adams, V., Conraads, V., Halle, M., Mezzani, A., Vanhees, L., Arena, R., Fletcher, G. F., Forman, D. E., Kitzman, D. W., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31826fb946 · Cited by 822
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
How to assess physical activity? How to assess physical fitness?
Vanhees, L., Lefevre, J., Philippaerts, R., Martens, M., Huygens, W., Troosters, T., & Beunen, G. (2005) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/00149831-200504000-00004 · Cited by 586
Wensel, R., Opitz, C. F., Anker, S. D., Winkler, J., Höffken, G., Kleber, F. X., Sharma, R., Hummel, M., Hetzer, R., & Ewert, R. (2002) · Circulation · doi:10.1161/01.cir.0000022687.18568.2a · Cited by 567
Metadata
- Authors
- Sun, X.-G., Hansen, J. E., Oudiz, R. J., & Wasserman, K.
- Venue
- Circulation
- Published
- 2002-01
- Volume
- 105
- Issue
- 1
- Pages
- 54-60
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2093076321
- Cited by
- 179
- References
- 0
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gas Exchange Detection of Exercise-Induced Right-to-Left Shunt in Patients With Primary Pulmonary Hypertension. https://app.cochat.ai/papers/10.1161/hc0102.101509
- The paper
- Sun, X.-G., Hansen, J. E., Oudiz, R. J., & Wasserman, K. (2002). Gas Exchange Detection of Exercise-Induced Right-to-Left Shunt in Patients With Primary Pulmonary Hypertension. Circulation. https://doi.org/10.1161/hc0102.101509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.