Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 224

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling

Open access
Barbone, Alessandro, Holmes, Jeff W., Heerdt, Paul M., The’, Andrew H.S., Naka, Yoshifumni, Joshi, Neel, Daines, Michael, Marks, Andrew R., Oz, Mehmet C., Burkhoff, Daniel·2001·Circulation

Abstract

Background — Left ventricular assist devices (LVAD) reverse ventricular, myocardial, and systemic abnormalities characteristic of severe heart failure (reverse remodeling). The relative contributions of hemodynamic unloading and normalized biochemical milieu to reverse remodeling are unknown. Methods and Results — Structural and functional characteristics were measured from 53 hearts of patients undergoing transplantation without LVAD support (medical support) and 33 hearts from patients receiving a median of 46 days of LVAD support (range, 8 to 360 days). Compared with medical support alone, patients receiving LVAD support for ≥30 days had higher central venous pressures (11±6 versus 8±5 mm Hg, P =0.04), lower pulmonary artery diastolic pressures (14±9 versus 21±9 mm Hg, P =0.01), and higher cardiac outputs (5.1±1.6 versus 3.7±1.0 L/min, P <0.001). In LVAD versus transplantation hearts, V 30 (ex vivo volume yielding ventricular pressure of 30 mm Hg) was decreased in the left ventricle (LV) (179±75 versus 261±118 mL, P =0.005) but not in the right ventricle (RV) (140±59 versus 148±52 mL, P =NS). LV myocyte diameter decreased more significantly after LVAD support (17%, P =0.05) than in the RV (11%, P =NS). Compared with transplantation, LVAD support increased normalized SERCA2a content in the LV (0.51±0.26 versus 1.04±0.34, P <0.001) but not in the RV (0.48±34 versus 0.67±0.55, P =NS). Finally, LVAD support improved force-frequency relations of isolated superfused LV trabeculae ( P =0.01) but not RV trabeculae. Conclusions — Reduction of hemodynamic load is a primary factor underlying several important features of reverse remodeling. These findings do not preclude a possible primary role of neurohormonal factors underlying other facets of reverse remodeling during LVAD support.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc3101.093903

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
Barbone, A., Holmes, J. W., Heerdt, P. M., The’, A. H. S., Naka, Y., Joshi, N., Daines, M., Marks, A. R., Oz, M. C., & Burkhoff, D.
Venue
Circulation
Published
2001-08-07
Volume
104
Issue
6
Pages
670-675
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2115607473
Cited by
224
References
1
FWCI
9.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling. https://app.cochat.ai/papers/10.1161/hc3101.093903
The paper
Barbone, A., Holmes, J. W., Heerdt, P. M., The’, A. H. S., Naka, Y., Joshi, N., Daines, M., Marks, A. R., Oz, M. C., & Burkhoff, D. (2001). Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling. Circulation. https://doi.org/10.1161/hc3101.093903

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.