The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Staphylococcus aureus Bacteremia in Patients With Permanent Pacemakers or Implantable Cardioverter-Defibrillators
Open accessAbstract
Background Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcus aureus bacteremia (SAB). Methods and Results A cohort of all adult patients with SAB and permanent pacemakers or implantable cardioverter-defibrillators over a 6-year period was evaluated prospectively. The overall incidence of confirmed CDI was 15 of 33 (45.4%). Confirmed CDI occurred in 9 of the 12 patients (75%) with early SAB (<1 year after device placement). Fifteen of 21 patients (71.5%) with late SAB (≥1 year after device placement) had either confirmed (6 of 21, 28.5%) or possible (9 of 21, 43%) CDI. In 60% of the patients (9 of 15) with confirmed CDI, no local signs or symptoms suggesting generator pocket infection were noted. Conclusions The incidence of CDI among patients with SAB and cardiac devices is high. Neither physical examination nor echocardiography can exclude the possibility of CDI. In patients with early SAB, the device is usually involved, and ≈40% of these patients have obvious clinical signs of cardiac device involvement. Conversely, in patients with late SAB, the cardiac device is rarely the initial source of bacteremia, and there is a paucity of local signs of device involvement. The cardiac device is involved, however, in ≥28% of these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Practice of Infectious Diseases.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-818_5 · Cited by 12,025
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Weinstein, M. P., Towns, M. L., Quartey, S. M., Mirrett, S., Reimer, L. G., Parmigiani, G., & Barth Reller, L. (1997) · Clinical Infectious Diseases · doi:10.1093/clind/24.4.584 · Cited by 1,228
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Fowler, V. G., Li, J., Corey, G. R., Boley, J., Marr, K. A., Gopal, A. K., Kong, L. K., Gottlieb, G., Donovan, C. L., Sexton, D. J., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00250-7 · Cited by 423
Self-citationPacemaker infective endocarditis
Cacoub, P., Leprince, P., Nataf, P., Hausfater, P., Dorent, R., Wechsler, B., Bors, V., Pavie, A., Piette, J. C., & Gandjbakhch, I. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00365-8 · Cited by 314
Risk factors for the development of prosthetic valve endocarditis.
Calderwood, S. B., Swinski, L. A., Waternaux, C. M., Karchmer, A. W., & Buckley, M. J. (1985) · Circulation · doi:10.1161/01.cir.72.1.31 · Cited by 271
Pacemaker Endocarditis Report of 44 Cases and Review of the Literature
Arber, N., Pras, E., Copperman, Y., Schapiro, J. M., Meiner, V., Lossos, I. S., Militianu, A., Hassin, D., Pras, E., Shai, A., et al. (1994) · Medicine · doi:10.1097/00005792-199411000-00003 · Cited by 251
Pacemaker lead infection: echocardiographic features, management, and outcome
Victor, F., De Place, C., Camus, C., Le Breton, H., Leclercq, C., Pavin, D., Mabo, P., & Daubert, C. (1999) · Heart · doi:10.1136/hrt.81.1.82 · Cited by 221
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Self-citationLiu, C., Bayer, A., Cosgrove, S. E., Daum, R. S., Fridkin, S. K., Gorwitz, R. J., Kaplan, S. L., Karchmer, A. W., Levine, D. P., Murray, B. E., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/ciq146 · Cited by 4,191
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.020 · Cited by 1,024
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Predictors of Mortality in Staphylococcus aureus Bacteremia
van Hal, S. J., Jensen, S. O., Vaska, V. L., Espedido, B. A., Paterson, D. L., & Gosbell, I. B. (2012) · Clinical Microbiology Reviews · doi:10.1128/cmr.05022-11 · Cited by 932
Fowler, V. G., Durack, D. T., Selton-Suty, C., Athan, E., Bayer, A. S., Chamis, A. L., Dahl, A., DiBernardo, L., Durante-Mangoni, E., Duval, X., et al. (2023) · Clinical Infectious Diseases · doi:10.1093/cid/ciad271 · Cited by 782
Self-citationManagement and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Nonvalvular Cardiovascular Device–Related Infections
Baddour, L. M., Bettmann, M. A., Bolger, A. F., Epstein, A. E., Ferrieri, P., Gerber, M. A., Gewitz, M. H., Jacobs, A. K., Levison, M. E., Newburger, J. W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093201.57771.47 · Cited by 496
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Self-citationPermanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Campoccia, D., Montanaro, L., & Arciola, C. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.048 · Cited by 340
Clinical Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac Devices
Chu, V. H. (2012) · JAMA · doi:10.1001/jama.2012.497 · Cited by 324
Wu, J. A., Kusuma, C., Mond, J. J., & Kokai-Kun, J. F. (2003) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.47.11.3407-3414.2003 · Cited by 289
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Shin, J., Yan, Y., Bai, W., Xue, Y., Gamble, P., Tian, L., Kandela, I., Haney, C. R., Spees, W., Lee, Y., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0300-4 · Cited by 263
Fowler, V. G., Justice, A., Moore, C., Benjamin, D. K., Woods, C. W., Campbell, S., Reller, L. B., Corey, G. R., Day, N. P. J., & Peacock, S. J. (2005) · Clinical Infectious Diseases · doi:10.1086/427806 · Cited by 262
Self-citationSurgical Treatment of Pacemaker and Defibrillator Lead Endocarditis
del Río, A., Anguera, I., Miró, J. M., Mont, L., Fowler, V. G., Azqueta, M., & Mestres, C. A. (2003) · Chest · doi:10.1378/chest.124.4.1451 · Cited by 256
Self-citation
Metadata
- Authors
- Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G.
- Venue
- Circulation
- Published
- 2001-08-28
- Volume
- 104
- Issue
- 9
- Pages
- 1029-1033
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2033138353
- Cited by
- 292
- References
- 30
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.