Catheter Stimulation of Cardiac Parasympathetic Nerves in Humans: A Novel Approach to the Cardiac Autonomic Nervous System
The DOI matches its Crossref record.
Abstract
Background Cardiac parasympathetic nerves run alongside the superior vena cava (SVC) and accumulate particularly epicardially adjacent to the orifice of the coronary sinus (CS). In animals, these nerves can be electrically stimulated inside the SVC or CS, which results in negative chronotropic/dromotropic effects and negative inotropic effects in the atria but not the ventricles. Parasympathetic nerve stimulation (PS) with 20 Hz in the CS, however, also excites the atria, thereby inducing atrial fibrillation. The present study overcomes this limitation by applying high-frequency nerve stimuli within the atrial refractory period. Using this technique, we investigated for the first time whether neurophysiological effects similar to those in animals can be obtained in humans. Methods and Results In 25 patients, parasympathetic nerves were stimulated via a multipolar electrode catheter placed in the SVC (stimulation with 20 Hz; n=14) or CS (pulsed 200-Hz stimuli; n=11). A significant sinus rate decrease and prolongation of the antegrade Wenckebach period was achieved during PS in the SVC. During PS in the CS, a graded-response prolongation of the antegrade Wenckebach interval was observed with increasing PS voltage until third-degree AV block occurred in 8 of 11 patients. The negative chronotropic/dromotropic effects started and terminated immediately after the onset and termination of PS, respectively. Atropine abolished these effects (n=11). Conclusions Human parasympathetic efferent nerve stimulation induces reversible negative chronotropic and dromotropic effects. PS may serve as an adjunctive tool for the diagnosis/treatment of supraventricular tachycardias and may be beneficial for ventricular rate slowing during tachycardic atrial fibrillation in patients with congestive heart failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac electrophysiology in mice: a matter of size
Kaese, S., & Verheule, S. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00345 · Cited by 196
“Chiamvimonvat et al., 1998; Schauerte et al., 2001; Dorian et al., 2007 33–80 Thomas et al., 1998; Verheule et al., 1999; Kovoor et al., 2001; Korte et al., 2002; Saba et al., 2005; van Veen et al., 2005; Zhang et al., 2005; Sawaya et al., 2007; Schrickel et al., 2007; Li et al., 2009; Stein et…”
Vagus nerve stimulation: From pre-clinical to clinical application: Challenges and future directions
De Ferrari, G. M., & Schwartz, P. J. (2011) · Heart Failure Reviews · doi:10.1007/s10741-010-9216-0 · Cited by 169
Saburkina, I., Rysevaite, K., Pauziene, N., Mischke, K., Schauerte, P., Jalife, J., & Pauza, D. H. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.02.036 · Cited by 69
Self-citationSalman, I. M. (2016) · Current Hypertension Reports · doi:10.1007/s11906-016-0625-x · Cited by 66
Metadata
- Authors
- Schauerte, P., Mischke, K., Plisiene, J., Waldmann, M., Zarse, M., Stellbrink, C., Schimpf, T., Knackstedt, C., Sinha, A., & Hanrath, P.
- Venue
- Circulation
- Published
- 2001-11-13
- Volume
- 104
- Issue
- 20
- Pages
- 2430-2435
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2137298524
- Cited by
- 73
- References
- 0
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.