The DOI matches its Crossref record.
Chronic Amiodarone Evokes No Torsade de Pointes Arrhythmias Despite QT Lengthening in an Animal Model of Acquired Long-QT Syndrome
Open accessAbstract
Background Amiodarone is an effective antiarrhythmic drug rarely associated with torsade de pointes arrhythmias (TdP). The noniodinated compound dronedarone could resemble amiodarone and be devoid of the adverse effects. In the dog with chronic complete atrioventricular (AV) block (CAVB) and acquired long-QT syndrome, the electrophysiological and proarrhythmic properties of the drugs were compared after 4 weeks of oral treatment. Methods and Results Amiodarone (n=7, 40 mg · kg −1 · d −1 ) and dronedarone (n=8, 20 mg/kg BID) were started at 6 weeks of CAVB (baseline). Six dogs served as controls. Surface ECGs and endocardially placed monophasic action potential catheters in the left (LV) and right (RV) ventricles were recorded to assess QTc time, action potential duration (APD), interventricular dispersion (ΔAPD=LV APD minus RV APD), early afterdepolarizations (EADs), ectopic beats, and TdP. Both amiodarone (+21%) and dronedarone (+31%) increased QTc time. Amiodarone showed no increase in ΔAPD in 4 of 7 dogs, whereas dronedarone augmented ΔAPD in 7 of 8 animals. After dronedarone, TdP occurred in 4 of 8 dogs with the highest ΔAPD (105±20 ms). TdP was never seen with amiodarone, not even in the dogs that had ΔAPD values comparable to those with dronedarone. Furthermore, a difference existed in EADs and ectopic activity incidence (dronedarone 3 of 8; amiodarone 0 of 7), which was also seen during an epinephrine challenge. Conclusions In the CAVB dog model, both amiodarone and dronedarone prolong QT time (class III effect). The absence of TdP with amiodarone seems to be related to homogeneous APD lengthening in the majority of dogs and the lack of EADs and/or ventricular ectopic beats in all.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrophysiological Effects of Ranolazine, a Novel Antianginal Agent With Antiarrhythmic Properties
Antzelevitch, C., Belardinelli, L., Zygmunt, A. C., Burashnikov, A., Di Diego, J. M., Fish, J. M., Cordeiro, J. M., & Thomas, G. (2004) · Circulation · doi:10.1161/01.cir.0000139333.83620.5d · Cited by 675
Drug‐Induced Torsades de Pointes and Implications for Drug Development
FENICHEL, R. R., MALIK, M., ANTZELEVITCH, C., SANGUINETTI, M., RODEN, D. M., PRIORI, S. G., RUSKIN, J. N., LIPICKY, R. J., CANTILENA, L. R., & Independent Academic Task Force (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03534.x · Cited by 346
Assessing predictors of drug-induced torsade de pointes
Belardinelli, L., Antzelevitch, C., & Vos, M. A. (2003) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2003.10.002 · Cited by 302
Self-citationHinterseer, M., Thomsen, M. B., Beckmann, B.-M., Pfeufer, A., Schimpf, R., Wichmann, H.-E., Steinbeck, G., Vos, M. A., & Kaab, S. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm586 · Cited by 126
Self-citation
Metadata
- Authors
- van Opstal, J. M., Schoenmakers, M., Verduyn, S. C., de Groot, S. H. M., Leunissen, J. D. M., van der Hulst, F. F., Molenschot, M. M. C., Wellens, H. J. J., & Vos, M. A.
- Venue
- Circulation
- Published
- 2001-11-27
- Volume
- 104
- Issue
- 22
- Pages
- 2722-2727
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2005534939
- Cited by
- 193
- References
- 0
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Amiodarone Evokes No Torsade de Pointes Arrhythmias Despite QT Lengthening in an Animal Model of Acquired Long-QT Syndrome. https://app.cochat.ai/papers/10.1161/hc4701.099579
- The paper
- van Opstal, J. M., Schoenmakers, M., Verduyn, S. C., de Groot, S. H. M., Leunissen, J. D. M., van der Hulst, F. F., Molenschot, M. M. C., Wellens, H. J. J., & Vos, M. A. (2001). Chronic Amiodarone Evokes No Torsade de Pointes Arrhythmias Despite QT Lengthening in an Animal Model of Acquired Long-QT Syndrome. Circulation. https://doi.org/10.1161/hc4701.099579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.