Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 510

The DOI matches its Crossref record.

Circulating Microparticles From Patients With Myocardial Infarction Cause Endothelial Dysfunction

Open access
Boulanger, Chantal M., Scoazec, Alexandra, Ebrahimian, Talin, Henry, Patrick, Mathieu, Eric, Tedgui, Alain, Mallat, Ziad·2001·Circulation

Abstract

Background Shed membrane microparticles circulate in the peripheral blood of nonischemic (NI) patients and patients with myocardial infarction (MI). We investigated whether or not these microparticles would affect endothelium-dependent responses. Methods and Results Rat aortic rings with endothelium were exposed for 24 hours to circulating microparticles isolated from 7 patients with NI syndromes and 19 patients with acute MI. Endothelium-dependent relaxations to acetylcholine were not affected by high concentrations of microparticles from NI patients ( P =0.80). However, significant impairment was observed in preparations exposed to microparticles from patients with MI at low and high concentrations, corresponding to 0.7-fold and 2-fold circulating plasma levels ( P =0.05 and 0.001, respectively). Impairment was not affected by diclofenac ( P =0.47), nor by the cell-permeable superoxide dismutase mimetic Mn(III)tetra(4-benzoic acid) porphyrin chloride ( P =0.33), but it was abolished by endothelium removal or by N ω monomethyl- l -arginine. Relaxations to the calcium ionophore ionomycin were decreased in rings exposed to microparticles from MI patients ( P =0.05 and 0.009 for low and high concentrations, respectively), but microparticles from NI patients had no effect ( P =0.81). Finally, high concentrations of microparticles from MI patients affected neither endothelium-independent relaxation to sodium nitroprusside ( P =0.59) nor expression of the endothelial nitric oxide synthase ( P =0.43). Conclusions Circulating microparticles from patients with MI selectively impair the endothelial nitric oxide transduction pathway and, therefore, could contribute to the general vasomotor dysfunction observed after MI, even in angiographically normal arteries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc4701.100516

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 510

Metadata

Authors
Boulanger, C. M., Scoazec, A., Ebrahimian, T., Henry, P., Mathieu, E., Tedgui, A., & Mallat, Z.
Venue
Circulation
Published
2001-11-27
Volume
104
Issue
22
Pages
2649-2652
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2111213998
Cited by
510
References
0
FWCI
6.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Circulating Microparticles From Patients With Myocardial Infarction Cause Endothelial Dysfunction. https://app.cochat.ai/papers/10.1161/hc4701.100516
The paper
Boulanger, C. M., Scoazec, A., Ebrahimian, T., Henry, P., Mathieu, E., Tedgui, A., & Mallat, Z. (2001). Circulating Microparticles From Patients With Myocardial Infarction Cause Endothelial Dysfunction. Circulation. https://doi.org/10.1161/hc4701.100516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.