Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 289

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Effects of Rapid Atrial Pacing on the Arrhythmogenic Activity of Single Cardiomyocytes From Pulmonary Veins: Implication in Initiation of Atrial Fibrillation

Open access
Chen, Yi-Jen, Chen, Shih-Ann, Chen, Yao-Chang, Yeh, Hung-I, Chan, Paul, Chang, Mau-Song, Lin, Cheng-I · 2001 · Circulation

Abstract

Background Pulmonary veins (PVs) are important sources of paroxysmal atrial fibrillation. Long-term rapid atrial pacing (RAP) changes atrial electrophysiology and facilitates the maintenance of atrial fibrillation. It is not clear whether RAP alters the arrhythmogenic activity of PVs. The purpose of this study was to isolate single PV cardiomyocytes from control and RAP dogs and evaluate their electrophysiological characteristics. Methods and Results The action potential and ionic currents were investigated in PV cardiomyocytes from control and long-term (6 to 8 weeks) RAP (780 bpm) dogs by use of the whole-cell clamp technique. Dissociation of PVs yielded rod-shaped single cardiomyocytes without (n=91, 60%) or with (n=60, 40%) pacemaker activity. Compared with the control group, the RAP dog PV cardiomyocytes had faster beating rates (0.86±0.28 versus 0.45±0.07 Hz, P <0.05) and shorter action potential duration. The RAP dog PV cardiomyocytes with pacemaker activity have a higher incidence of delayed (59% versus 7%, P <0.001) or early (24% versus 0%, P <0.005) afterdepolarization. The RAP dog PV cardiomyocytes with pacemaker activity had smaller slow inward and transient outward but larger transient inward (0.017±0.004 versus 0.009±0.002 pA/pF, P <0.05) and pacemaker (0.111±0.019 versus 0.028±0.008 pA/pF, P <0.001) currents. The RAP dog PV cardiomyocytes without pacemaker activity had only smaller slow inward and transient outward and larger pacemaker currents. Conclusions PVs contain multiple cardiomyocytes with distinct electrophysiological characteristics. RAP changes the electrophysiological characteristics and arrhythmogenic activity of PVs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc4801.099736

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 289

Metadata

Authors
Chen, Y.-J., Chen, S.-A., Chen, Y.-C., Yeh, H.-I., Chan, P., Chang, M.-S., & Lin, C.-I.
Venue
Circulation
Published
2001-12-04
Volume
104
Issue
23
Pages
2849-2854
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2148644439
Cited by
289
References
18
FWCI
13.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Rapid Atrial Pacing on the Arrhythmogenic Activity of Single Cardiomyocytes From Pulmonary Veins: Implication in Initiation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/hc4801.099736
The paper
Chen, Y.-J., Chen, S.-A., Chen, Y.-C., Yeh, H.-I., Chan, P., Chang, M.-S., & Lin, C.-I. (2001). Effects of Rapid Atrial Pacing on the Arrhythmogenic Activity of Single Cardiomyocytes From Pulmonary Veins: Implication in Initiation of Atrial Fibrillation. Circulation. https://doi.org/10.1161/hc4801.099736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.