Blood Pressure Variability and Organ Damage in a General Population: Results from the PAMELA Study
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
In hypertensive patients, 24-hour blood pressure (BP) variability (V) shows a positive relationship with organ damage, organ damage progression, and cardiovascular morbidity. The clinical relevance of BPV in the population has never been investigated. In a sample of 3200 individuals, randomly selected from the general population of Monza (Milan, Italy), we evaluated BP by an automatic oscillometric device every 20 minutes for 24 hours and left ventricular mass index (LVMI) by echocardiography. In each subject, individual systolic and diastolic BP readings were averaged to obtain a 24-hour mean. Systolic BPV was obtained by calculating (1) the standard deviation of the 24-hour mean, which was taken as the overall BPV, (2) the cyclic components (Fourier spectral analysis) that in the population as a whole explained >95% of the overall BPV, and (3) the fraction of the overall BPV that in each subject was not accounted for by the 2 cyclic components, termed individual residual BPV. A similar procedure was used for diastolic BP and heart rate. Participation rate was 64.1%. Patients receiving antihypertensive therapy (n=403) were excluded from the analysis, which was therefore limited to 1648 participants. In the population as a whole, LVMI significantly related to 24-hour systolic and diastolic BP mean (β=0.40 and β=0.37, respectively, P <0.001 for both) but not to the 2 cyclic components that accounted for most of the BPV. On the other hand, the individual residual BPV (which accounts on average for about 50% of overall BPV) showed a significant positive relationship with LVMI (β =0.38 and β=0.88 for systolic and diastolic BP, respectively, P <0.05 and P <0.01). No relationship was found between LVMI and heart rate values. These findings provide evidence that there is a relationship between LVMI and 24-hour average BP values in the population. They also provide the first demonstration that in the population there is also a positive independent association between LVMI and BPV. This association, however, can be exclusively seen with the BPV component that has an erratic rather than a cyclic nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.
Devereux, R. B., & Reichek, N. (1977) · Circulation · doi:10.1161/01.cir.55.4.613 · Cited by 4,485
WHO MONICA Project Principal Invest (1988) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(88)90084-4 · Cited by 1,794
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?: The Framingham Heart Study
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,759
Kornitzer, M., Berghmans, L., Wilmet, M. D., Darquennes, H., Lagasse, R., & Payen, R. (1988) · Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) · Cited by 1,270
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Self-citationEchocardiographic criteria for left ventricular hypertrophy: The Framingham heart study
Levy, D., Savage, D. D., Garrison, R. J., Anderson, K. M., Kannel, W. B., & Castelli, W. P. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)91133-7 · Cited by 799
Blood pressure and heart rate variabilities in normotensive and hypertensive human beings.
Mancia, G., Ferrari, A., Gregorini, L., Parati, G., Pomidossi, G., Bertinieri, G., Grassi, G., di Rienzo, M., Pedotti, A., & Zanchetti, A. (1983) · Circulation Research · doi:10.1161/01.res.53.1.96 · Cited by 776
Self-citationPrognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Self-citation
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationAssessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Tobin, M. D., Sheehan, N. A., Scurrah, K. J., & Burton, P. R. (2005) · Statistics in Medicine · doi:10.1002/sim.2165 · Cited by 691
Mascha, E. J., Yang, D., Weiss, S., & Sessler, D. I. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000686 · Cited by 387
Mancia, G., Bombelli, M., Facchetti, R., Madotto, F., Corrao, G., Trevano, F. Q., Grassi, G., & Sega, R. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.088708 · Cited by 376
Self-citationTwenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
Amin, R. S., Carroll, J. L., Jeffries, J. L., Grone, C., Bean, J. A., Chini, B., Bokulic, R., & Daniels, S. R. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1305oc · Cited by 354
Parving, H.-H., Brenner, B. M., McMurray, J. J. V., de Zeeuw, D., Haffner, S. M., Solomon, S. D., Chaturvedi, N., Ghadanfar, M., Weissbach, N., Xiang, Z., et al. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn721 · Cited by 304
Tatasciore, A., Renda, G., Zimarino, M., Soccio, M., Bilo, G., Parati, G., Schillaci, G., & De Caterina, R. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090084 · Cited by 292
Schillaci, G., Bilo, G., Pucci, G., Laurent, S., Macquin-Mavier, I., Boutouyrie, P., Battista, F., Settimi, L., Desamericq, G., Dolbeau, G., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.197491 · Cited by 285
Left Ventricular Hypertrophy and Clinical Outcomes in Hypertensive Patients
Ruilope, L. M., & Schmieder, R. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.16 · Cited by 258
Brouwers, S., Sudano, I., Kokubo, Y., & Sulaica, E. M. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00221-x · Cited by 257
Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka-Jaszcz, K., Mancia, G., & Parati, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32829c6a60 · Cited by 246
Self-citationBlood Pressure Variability: Assessment, Predictive Value, and Potential as a Therapeutic Target
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2015) · Current Hypertension Reports · doi:10.1007/s11906-015-0537-1 · Cited by 215
Zhang, Y., Agnoletti, D., Safar, M. E., & Blacher, J. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.174383 · Cited by 162
Verreth, W., De Keyzer, D., Pelat, M., Verhamme, P., Ganame, J., Bielicki, J. K., Mertens, A., Quarck, R., Benhabilès, N., Marguerie, G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000147614.85888.7a · Cited by 131
Bombelli, M., Facchetti, R., Sega, R., Carugo, S., Fodri, D., Brambilla, G., Giannattasio, C., Grassi, G., & Mancia, G. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.175125 · Cited by 126
Self-citationParati, G., Ochoa, J. E., Bilo, G., Agarwal, R., Covic, A., Dekker, F. W., Fliser, D., Heine, G. H., Jager, K. J., Gargani, L., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06896 · Cited by 112
Hoshide, S., Yano, Y., Shimizu, M., Eguchi, K., Ishikawa, J., & Kario, K. (2012) · Hypertension Research · doi:10.1038/hr.2012.46 · Cited by 28
Association of blood pressure variability with orthostatic intolerance symptoms
Sunwoo, J.-S., Yang, T.-W., Kim, D.-Y., Lim, J.-A., Kim, T.-J., Byun, J.-I., Moon, J., Lee, S.-T., Jung, K.-H., Park, K.-I., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0179132 · Cited by 16
Chi, C., Yu, S.-K., Auckle, R., Argyris, A. A., Nasothimiou, E., Tountas, C., Aissopou, E., Blacher, J., Safar, M. E., Sfikakis, P. P., et al. (2017) · Journal of Human Hypertension · doi:10.1038/jhh.2017.37 · Cited by 12
Yu, S., Chi, C., Protogerou, A. D., Safar, M. E., Blacher, J., Argyris, A. A., Nasothimiou, E. G., Sfikakis, P. P., Papaioannou, T. G., Xu, H., et al. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13226 · Cited by 9
Metadata
- Authors
- Sega, R., Corrao, G., Bombelli, M., Beltrame, L., Facchetti, R., Grassi, G., Ferrario, M., & Mancia, G.
- Venue
- Hypertension
- Published
- 2002-02
- Volume
- 39
- Issue
- 2
- Pages
- 710-714
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2126467846
- Cited by
- 276
- References
- 23
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.