CoChat

Pulse Pressure Is Inversely Related to Aortic Root Diameter Implications for the Pathogenesis of Systolic Hypertension

Open access
Farasat, S. Morteza, Morrell, Christopher H., Scuteri, Angelo, Ting, Chih-Tai, Yin, Frank C.P., Spurgeon, Harold A., Chen, Chen-Huan, Lakatta, Edward G., Najjar, Samer S. · 2008 · Hypertension
Cited by 85

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Hypertension accelerates the age-associated increase in aortic root diameter (AoD), likely because of chronically elevated distending pressures. However, the pulsatile component of blood pressure may have a different relationship with AoD. We sought to assess the relationship between AoD and pulse pressure (PP) while accounting for left ventricular and central arterial structural and functional properties, which are known to influence PP. The study population was composed of 1256 individuals, aged 30 to 79 years (48% women and 48% hypertensive), none of whom were on antihypertensive medications. Blood pressure was measured in the sitting position with conventional sphygmomanometry. PP was calculated as the difference between systolic and diastolic blood pressures. AoD was measured at end diastole at the level of the sinuses of Valsalva with echocardiography. The relationship between AoD and PP was evaluated with multiple regression analyses. PP was 50±14 mm Hg in men and 54±18 mm Hg in women, and AoD was 31.9±3.5 mm in men and 28.9±3.5 mm in women. After adjusting for age, age 2 , height, weight, and mean arterial pressure, AoD was independently and inversely associated with PP in both sexes. After further adjustments for central arterial stiffness and wall thickness, reflected waves, and left ventricular geometry, AoD remained inversely associated with PP in both men (coefficient=−0.48; P =0.0003; model R 2 =0.51) and women (coefficient=−0.40; P =0.01; model R 2 =0.61). Thus, AoD is inversely associated with PP, suggesting that a small AoD may contribute to the pathogenesis of systolic hypertension. Longitudinal studies are needed to examine this possibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.107.099515

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 85

Metadata

Authors
Farasat, S. M., Morrell, C. H., Scuteri, A., Ting, C.-T., Yin, F. C. P., Spurgeon, H. A., Chen, C.-H., Lakatta, E. G., & Najjar, S. S.
Venue
Hypertension
Published
2008-02
Volume
51
Issue
2
Pages
196-202
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2102615651
Cited by
85
References
7
FWCI
2.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse Pressure Is Inversely Related to Aortic Root Diameter Implications for the Pathogenesis of Systolic Hypertension. https://app.cochat.ai/papers/10.1161/hypertensionaha.107.099515
The paper
Farasat, S. M., Morrell, C. H., Scuteri, A., Ting, C.-T., Yin, F. C. P., Spurgeon, H. A., Chen, C.-H., Lakatta, E. G., & Najjar, S. S. (2008). Pulse Pressure Is Inversely Related to Aortic Root Diameter Implications for the Pathogenesis of Systolic Hypertension. Hypertension. https://doi.org/10.1161/hypertensionaha.107.099515

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.