The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Abstract
T he widely accepted cut-point for normal blood pressure (BP) in the office setting evolved over several decades, based on data derived from a variety of sources.The Actuarial Society of America was one of the first organizations to publish BP data on thousands of community residents, followed by other classic studies such as Framingham, Western Electric Company, Kaiser Permanente, and the Multiple Risk Factor Intervention Trial. 1,2In every instance, BP readings were based on measurements taken by specially trained health professionals following guidelines for proper BP measurement.As a result of these and other population studies examining the association between different BP levels and cardiovascular outcomes, the importance of systolic and diastolic hypertension was recognized and an office BP of 140/90 mm Hg became the universally established cut-point for separating normal BP from hypertension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“further measurement bias can be introduced to office BP if the person doing the measurement had poor adherence to measurement recommendations. 53”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Dahlöf, B., Sever, P. S., Poulter, N. R., Wedel, H., Beevers, D. G., Caulfield, M., Collins, R., Kjeldsen, S. E., Kristinsson, A., McInnes, G. T., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67185-1 · Cited by 2,909
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Fagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Alerting reaction and rise in blood pressure during measurement by physician and nurse.
Mancia, G., Parati, G., Pomidossi, G. A., Grassi, G. M., Casadei, R., & Zanchetti, A. (1987) · Hypertension · doi:10.1161/01.hyp.9.2.209 · Cited by 478
Poulter, N. R., Wedel, H., Dahlöf, B., Sever, P. S., Beevers, D. G., Caulfield, M., Kjeldsen, S. E., Kristinsson, A., McInnes, G. T., Mehlsen, J., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67186-3 · Cited by 319
Rutan, G. H., Kuller, L. H., Neaton, J. D., Wentworth, D. N., McDonald, R. H., & Smith, W. M. (1988) · Circulation · doi:10.1161/01.cir.77.3.504 · Cited by 308
Results of the Ontario Survey on the Prevalence and Control of Hypertension
Leenen, F. H. H., Dumais, J., McInnis, N. H., Turton, P., Stratychuk, L., Németh, K., Lum-Kwong, M. M., & Fodor, G. J. (2008) · Canadian Medical Association Journal · doi:10.1503/cmaj.071340 · Cited by 248
White, W. B., & Anwar, Y. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200104000-00007 · Cited by 213
Research works printed but not linked: 5
- Pickering G. High blood pressure. London: J&A Churchill Ltd; 1968: 229.
- 10.1161/circ.77.3.3277736 · DOI
- Ishikawa J. Nasothimiou E, Karpettas N, Feltheimer S, McDoniel S, Schwartz J Stergiou G, Pickering T. Automatic office blood pressure measurement without doctors or nurses present is more predictive of ambulatory blood pressure than is office blood pressure by mercury sphygmomanometer. J Hypertens. 2009; 27 (Suppl 4): S170.
- 10.1001/archinte.1993.00410240045005 · DOI
- Myers MG, Dawes M, Godwin M, Kaczorowski J, Kiss A, Tobe SW Minimum number of readings for automated office blood pressure measurement. J Hypertens. 2009; 27 (Suppl 4): S197.
Cited by
Sorted by citations
Items 101–200 of 254
Sheppard, J. P., Martin, U., Gill, P. S., Stevens, R., Hobbs, R. F., Mant, J., Godwin, M. S., Hanley, J., McKinstry, B., Myers, M. G., et al. (2018) · BMJ · doi:10.1136/bmj.k2478 · Cited by 21
Self-citationEffects of Reduced Kidney Function Because of Living Kidney Donation on Left Ventricular Mass
Altmann, U., Böger, C. A., Farkas, S. A., Mack, M., Luchner, A., Hamer, O. W., Zeman, F., Debl, K., Fellner, C., Jungbauer, C. G., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08175 · Cited by 21
Taking blood pressure: Too important to trust to humans?
Vidt, D. G., Lang, R. S., Seballos, R. J., Misra‐Hebert, A. D., Campbell, J., & Bena, J. (2010) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.77a.09155 · Cited by 20
Fishman, P. A., Anderson, M. L., Cook, A. J., Ralston, J. D., Catz, S. L., Carlson, J., Larson, E. B., & Green, B. B. (2011) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2011.00528.x · Cited by 20
Automated Office Blood Pressure Measurement
Myers, M. G. (2018) · Korean Circulation Journal · doi:10.4070/kcj.2018.0066 · Cited by 20
Self-citationBo, Y., Kwok, K. O., Chu, K. K.-Y., Leung, E. Y.-H., Yu, C. P., Wong, S. Y. S., & Lee, E. K. P. (2021) · Current Hypertension Reports · doi:10.1007/s11906-020-01118-1 · Cited by 19
Hypertension up to date: SPRINT to SPYRAL
Kulenthiran, S., Ewen, S., Böhm, M., & Mahfoud, F. (2017) · Clinical Research in Cardiology · doi:10.1007/s00392-017-1095-0 · Cited by 18
Impact of the SPRINT Trial on Hypertension Management
Ghazi, L., & Oparil, S. (2018) · Annual Review of Medicine · doi:10.1146/annurev-med-050416-024516 · Cited by 18
Cardiovascular risk factors in patients with first-episode psychosis in São Paulo, Brazil
Benseñor, I. M., Brunoni, A. R., Pilan, L. A., Goulart, A. C., Busatto, G. F., Lotufo, P. A., Scazufca, M., & Menezes, P. R. (2012) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2011.12.010 · Cited by 18
Screening For Hypertension Annually Compared With Current Practice
Garrison, G. M., & Oberhelman, S. S. (2013) · The Annals of Family Medicine · doi:10.1370/afm.1467 · Cited by 18
Mirdamadi, A., & Etebari, M. (2017) · PubMed Central · Cited by 18
Yeung, S. E., & Thornton, W. L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0177424 · Cited by 18
Clinical Implications of Different Blood Pressure Measurement Techniques
Drawz, P. E. (2017) · Current Hypertension Reports · doi:10.1007/s11906-017-0751-0 · Cited by 18
Blood Pressure Measurement in the Post-SPRINT Era
Myers, M. G., Cloutier, L., Gelfer, M., Padwal, R. S., & Kaczorowski, J. A. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07598 · Cited by 18
Self-citationPfister, C.-L., Govender, S., Dyer, R. A., Rayner, B. L., Flint, M., Roodt, F., Davids, J., Nejthardt, M., Swanevelder, J. L., Chiu, C.-J. E., et al. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004966 · Cited by 17
Age-dependent changes in blood pressure over consecutive office measurements
Veloudi, P., Blizzard, C. L., Srikanth, V. K., Breslin, M. C., Schultz, M. G., & Sharman, J. E. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001227 · Cited by 17
Do We Need a New Definition of Hypertension After SPRINT?
Schiffrin, E. L., Calhoun, D. A., & Flack, J. M. (2016) · American Journal of Hypertension · doi:10.1093/ajh/hpw068 · Cited by 17
Papademetriou, V., Tsioufis, C. P., Chung, A., Geladari, C. V., & Andreadis, E. A. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13371 · Cited by 16
Effects of Noise and Public Setting on Blood Pressure Readings
Ishigami, J., Liu, H., Zhao, D., Sabit, A. H., Pathiravasan, C. H., Charleston, J. B., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M. (2025) · Annals of Internal Medicine · doi:10.7326/annals-24-00873 · Cited by 16
Twenty-four-hour ambulatory blood pressure monitoring in hypertension: an evidence-based analysis.
(2012) · Europe PMC (PubMed Central) · Cited by 16
Comparison of Acceptability of Traditional and Novel Blood Pressure Measurement Methods
Lindroos, A. S., Jula, A., Puukka, P. J., Kantola, I. M., Salomaa, V. V., Juhanoja, E. P., Sivén, S. S. E., Jousilahti, P., & Niiranen, T. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv167 · Cited by 15
Boonyasai, R. T., McCannon, E. L., & Landavaso, J. E. (2019) · Current Hypertension Reports · doi:10.1007/s11906-019-0936-9 · Cited by 15
Chapman, N., McWhirter, R., Jose, K., Schultz, M. G., Ezzy, D., Nelson, M. R., & Sharman, J. E. (2021) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13569 · Cited by 15
Österreichischer Blutdruckkonsens 2019
Hypertensiologie, Ö. G. F., Weber, T., Atherosklerosegesellschaft, Ö., Gesellschaft, Ö. D., Angiologie, Ö. G. F. I., Nephrologie, Ö. G. F., Gesellschaft, Ö. K., Neurologie, Ö. G. F., Schlaganfall-Gesellschaft, Ö., Allgemeinmedizin, Ö. G. F., et al. (2019) · Wiener klinische Wochenschrift · doi:10.1007/s00508-019-01565-0 · Cited by 15
Lee, J. Y., & Azar, S. H. (2010) · Experimental Biology and Medicine · doi:10.1258/ebm.2010.010081 · Cited by 15
Under pressure: the lifelong cardiovascular health of children and youth with primary hypertension
Chanchlani, R., Brady, T. M., Kruger, R., & Sinha, M. D. (2025) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(25)00302-5 · Cited by 15
Why Automated Office Blood Pressure Should Now Replace the Mercury Sphygmomanometer
Myers, M. G. (2010) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2010.00301.x · Cited by 13
Self-citationShould blood pressure goal be individualized in hypertensive patients?
Yannoutsos, A., Fekih, R. E., Halimi, J., Safar, M. E., & Blacher, J. (2016) · Pharmacological Research · doi:10.1016/j.phrs.2016.11.037 · Cited by 13
Patil, S. J., Wareg, N. K., Hodges, K. L., Smith, J. B., Kaiser, M. S., & LeFevre, M. L. (2020) · The Annals of Family Medicine · doi:10.1370/afm.2491 · Cited by 13
Doane, J., Flynn, M. C., Archibald, M., Ramírez, D. D. L. A., Conroy, M. B., & Stults, B. M. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13840 · Cited by 13
More Versus Less Blood Pressure Lowering: An Update
Atkins, E. R., & Rodgers, A. (2016) · Clinical Therapeutics · doi:10.1016/j.clinthera.2016.08.007 · Cited by 12
Solà, J., Vybornova, A., Fallet, S., Olivero, E., Marco, B. D., Grossenbacher, O., Ignjatovic, N., Ignjatovic, B., Favre-Bulle, M., Levinson, N., et al. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176286 · Cited by 12
Automated office blood pressure—the preferred method for recording blood pressure
Myers, M. G. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.01.007 · Cited by 12
Self-citationAutomatic office blood pressure measured without doctors or nurses present
Ishikawa, J., Nasothimiou, E. G., Karpettas, N., McDoniel, S. O., Feltheimer, S. D., Stergiou, G. S., Pickering, T. G., & Schwartz, J. E. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328352ade4 · Cited by 11
Diagnostic Performance of Blood Pressure Measurement Modalities in Living Kidney Donor Candidates
Armanyous, S. R., Ohashi, Y., Lioudis, M., Schold, J. D., Thomas, G., Poggio, E. D., & Augustine, J. J. (2019) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02780218 · Cited by 11
Relationship between arterial stiffness and unattended or attended blood pressure values
Paini, A., Aggiusti, C., Bertacchini, F., Stassaldi, D., Capellini, S., Ciuceis, C. D., Saccà, G., Verzeri, L., Gatta, R., Rosei, E. A., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002232 · Cited by 11
García‐Donaire, J. A., Baqué, A. D., Anso, C. S., Castillo, D. U., Debén, F. M., López, N. O., Núñez, J. L. P., Martín-Oterino, J.-Á., Herreros, J. G.-N., García, J. D. M., et al. (2012) · Medicina Clínica · doi:10.1016/j.medcli.2011.10.030 · Cited by 11
D’Sa, L., Senaratne, N., Woodcock-Smith, J., Miles, K. M., Wilkinson, I. B., & McEniery, C. M. (2018) · Hypertension Research · doi:10.1038/s41440-018-0120-7 · Cited by 10
Cheng, H., Sung, S., Chen, C.-H., Yu, W., Yang, S.-M., Guo, C., Chuang, S., & Chiang, C. (2019) · Trials · doi:10.1186/s13063-019-3366-8 · Cited by 10
Short-Term Test-Retest Reliability of Respiratory Sinus Arrhythmia (RSA) in Young Adults
Borges, C., Mathewson, K. J., & Schmidt, L. A. (2017) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000187 · Cited by 10
Fink, J. T., Magnan, E. M., Johnson, H. M., Bednarz, L., Allen, G. O., Greenlee, R. T., Bolt, D. M., & Smith, M. A. (2018) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-018-0284-x · Cited by 9
Huang, Z., Li, X., Liu, X., Xu, Y., Feng, H., & Ren, L. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1298612 · Cited by 10
Why Use Automated Office Blood Pressure Measurements in Clinical Practice?
Andreadis, E. A., Angelopoulos, E. T., Agaliotis, G. D., Tsakanikas, A. P., & Mousoulis, G. P. (2011) · High Blood Pressure & Cardiovascular Prevention · doi:10.2165/11593510-000000000-00000 · Cited by 9
Roush, G. C., Zubair, A., Singh, K. N., Kostis, W. J., Sica, D. A., & Kostis, J. B. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002079 · Cited by 9
Measurement of blood pressure: New developments and challenges
Kaczorowski, J. A., Dawes, M. G., & Gelfer, M. (2012) · Cited by 9
Self-citationKumar, D., Singh, S., Kashyap, V., & Singh, S. K. (2020) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_796_19 · Cited by 9
Blood pressure targets in chronic kidney disease: still no consensus
Lucas, B. J., & Taal, M. W. (2023) · Current Opinion in Nephrology & Hypertension · doi:10.1097/mnh.0000000000000920 · Cited by 8
Yarows, S. A. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13101 · Cited by 8
Hypertension Canada’s 2016 Canadian Hypertension Education Program guidelines for pharmacists
Hamarneh, Y. N. A., Houle, S. K. D., Padwal, R. S., & Tsuyuki, R. T. (2016) · Canadian Pharmacists Journal / Revue des Pharmaciens du Canada · doi:10.1177/1715163516671747 · Cited by 8
Palomba, C., Donadio, S., Canciello, G., Losi, M. A., Izzo, R., Manzi, M. V., Pisapia, F. D., Mancusi, C., & LUCA, N. D. (2019) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-019-00337-1 · Cited by 8
Vinyoles, E., Camafort, M., Doménech, M., Coca, A., & Sobrino, J. (2015) · Revista Clínica Española · doi:10.1016/j.rce.2015.06.007 · Cited by 8
Why Is It That We Continue to Deny Patients Ambulatory Blood Pressure Monitoring?
O'Brien, E. T. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06777 · Cited by 8
Contributions to Hypertension Public Policy and Clinical Practice: A Review of Recent Reports
Weber, M. A., & Lackland, D. T. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12902 · Cited by 7
An analysis of blood pressure measurement in a primary care hospital in Swaziland
Mlawanda, G., Pather, M. K., & Govender, S. (2014) · African Journal of Primary Health Care & Family Medicine · doi:10.4102/phcfm.v6i1.590 · Cited by 7
Makowsky, M. J., Prebtani, A. P. H., Gelfer, M., Manohar, A., & Jones, C. (2012) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2012.09.002 · Cited by 6
Myers, M. G. (2011) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2011.00505.x · Cited by 6
Self-citationDasgupta, K., Padwal, R. S., Poirier, L., & Quinn, R. R. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.131440 · Cited by 6
Cao, D. X., & Tran, R. J. C. (2018) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1002/phar.2081 · Cited by 6
Puig, A. O., Pibernat, A. D., Rosas, N., Isaac, E. M., Pérez-Romero, L. Á., Llorach, E. G., & Pibernat, A. D. (2014) · Hipertensión y Riesgo Vascular · doi:10.1016/j.hipert.2014.09.001 · Cited by 5
New trends in hypertension management: of salt, going solo and single pill combos
Dresser, G. K., & Feldman, R. D. (2010) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e32833a6e09 · Cited by 5
Automated office blood pressure measurement for routine clinical practice
Myers, M. G., Nelson, M. R., & Head, G. A. (2012) · The Medical Journal of Australia · doi:10.5694/mja11.11545 · Cited by 5
Self-citationTreatment of hypertension in older people
Wing, L. M. H., & Gabb, G. M. (2018) · Journal of Pharmacy Practice and Research · doi:10.1002/jppr.1417 · Cited by 5
The frequency and determinants of blood pressure measurement by a health professional in Germany
Diederichs, C., & Neuhauser, H. K. (2019) · Medicine · doi:10.1097/md.0000000000015093 · Cited by 5
What Is the Hypertension “Phenotype”?
Burnier, M., & Wuerzner, G. (2015) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-015-0438-5 · Cited by 5
Fujiwara, T., & Kario, K. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13037 · Cited by 5
Hypertension Prevalence and Control: Impact of Method of Blood Pressure Measurement
Cloutier, L., & Schiffrin, E. L. (2012) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-012-0247-z · Cited by 5
Should the measurement of blood pressure in the office be redefined?
Stergiou, G. S., & Parati, G. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328358a221 · Cited by 5
Blood pressure - Methods to record & numbers that are significant
Wander, G. S., & Ram, C. V. S. (2018) · The Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_842_18 · Cited by 5
Lan, P. G., Clayton, P. A., Hyett, J. A., & Gillin, A. G. (2013) · Hypertension in Pregnancy · doi:10.3109/10641955.2013.843007 · Cited by 4
Gorbunov, V. M. (2018) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2018-14-1-122-130 · Cited by 4
Gorbunov, V. M., Fedorova, E. Y., & Вячеславовна, П. Е. (2020) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2020-02-10 · Cited by 4
Machado, A. P. (2020) · Chronobiology International · doi:10.1080/07420528.2020.1781358 · Cited by 4
Sheppard, J. P., Martin, U., Gill, P. S., Stevens, R., & McManus, R. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012607 · Cited by 3
Resistant Hypertension in Adults With Type 1 or 2 Diabetes: A Structured Diagnostic Approach
McFarlane, P. A. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2018.01.001 · Cited by 3
The role of clinic blood pressure for the diagnosis of hypertension
Ayan, M., Kadavath, S. M., & Campbell, P. T. (2018) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000528 · Cited by 3
Kwun, J.-S., Kim, S., Kang, S., Yoon, C., Lee, H., Kim, K., Youn, T., Chae, I., & Kim, C. (2020) · Clinical Hypertension · doi:10.1186/s40885-020-0137-5 · Cited by 3
Michea, L., Toro, L., Alban, N., Contreras, D., Morgado, P., Paccot, M., Escobar, M. C., & Lorca, E. (2021) · Southern Medical Journal · doi:10.14423/smj.0000000000001206 · Cited by 3
Utility of 24-hour ambulatory blood pressure monitoring in potential living kidney donors
Aslam, N., Memon, S. H., Wadei, H. M., Lesser, E. R., & Niazi, S. K. (2021) · Clinical Hypertension · doi:10.1186/s40885-021-00172-4 · Cited by 3
Sisó‐Almirall, A., Kostov, B., Blat, E., García, N., de Andres, B., Roura, S., Sierra-Benito, C., Alvira-Balada, M. C., Colungo, C., Benavent-Àreu, J., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000003029 · Cited by 3
Atasoy, S., Henningsen, P., Johar, H., Middeke, M., Sattel, H. C., Linkohr, B., Rückert‐Eheberg, I., Heier, M., Peters, A., & Ladwig, K. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003629 · Cited by 3
Ma, J., Tang, X., Zhao, J., Zhang, J., Wang, Q., Wang, Y., Yang, Q., Shi, Y., Cheng, M., Wang, Y., et al. (2024) · Hypertension Research · doi:10.1038/s41440-024-01687-7 · Cited by 3
Cohen, D. L., & Townsend, R. R. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12527 · Cited by 3
Seo, J., Lee, C. J., Hwang, J., Oh, J., Lee, S., Kang, S., Choi, D., Kim, H. C., & Park, S. (2018) · American Journal of Hypertension · doi:10.1093/ajh/hpy081 · Cited by 3
Philibert, W., Andersen, A. M., Hoffman, E. A., Philibert, R. A., & Dogan, M. V. (2021) · Processes · doi:10.3390/pr9040699 · Cited by 3
Measurement of Blood Pressure in the Office
Martin, C., Cameron, J. D., Chen, S. S., & McGrath, B. P. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.154625 · Cited by 3
Targeting the myocardium in hypertensive left ventricular hypertrophy
Chin, C. W.-L. (2017) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2017.1361320 · Cited by 3
Ewen, S., Lobo, M. D., Pathak, A., Schmieder, R. E., Tsioufis, C. P., Wijns, W. C., & Mahfoud, F. (2016) · EuroIntervention · doi:10.4244/eijv12i6a132 · Cited by 2
Design of Ambulatory Blood Pressure Monitoring for IOT-Based Hypertension Patients
Sari, A. N., Nugraha, P. C., Mak’ruf, M. R., Ariswati, H. G., Putra, M. P. A. T., & Maghfiroh, A. M. (2024) · Jurnal Teknokes · doi:10.35882/teknokes.v17i1.646 · Cited by 2
Aslam, N., Missick, S., & Haley, W. E. (2019) · Advances in Chronic Kidney Disease · doi:10.1053/j.ackd.2019.02.001 · Cited by 2
Target levels of blood pressure in patients with arterial hypertension and coronary heart disease
Cherniaeva, M. S., & Ostroumova, O. D. (2020) · Arterial’naya Gipertenziya (Arterial Hypertension) · doi:10.18705/1607-419x-2020-26-1-15-26 · Cited by 2
Evaluation of Hypertension in Living Donor Candidates
Doshi, M. D., & Taler, S. J. (2021) · Springer eBooks · doi:10.1007/978-3-030-53618-3_5 · Cited by 2
Nurse prescribing for the management of hypertension
Bostock-Cox, B. (2013) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2013.8.11.531 · Cited by 2
What is the Cost of Measuring a Blood Pressure?
Yarows, S. A. (2018) · Annals of Clinical Hypertension · doi:10.29328/journal.ach.1001012 · Cited by 2
Predictive Factors for White-Coat Hypertension
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2014) · Springer eBooks · doi:10.1007/978-3-319-07410-8_4 · Cited by 2
New developments and challenges
Xie, I., & Matusiak, K. K. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-417112-1.00011-9 · Cited by 2
Sobana, R., & Parthasarathy, S. (2018) · Asian Journal of Pharmaceutical and Clinical Research · doi:10.22159/ajpcr.2018.v11i2.21959 · Cited by 2
Warda, H. M., Elshorbagy, A. K., Habib, A., Wagdi, A., Mihailidou, A. S., & Warda, M. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.14048 · Cited by 2
Alqaderi, H. E., Al‐Ozairi, E., Bin‐Hasan, S., Tavares, M. A., Goodson, J. M., Alsumait, A., Abu‐Farha, M., Abubaker, J. A., Devarajan, S., Almuhana, N., et al. (2020) · Biomarkers in Medicine · doi:10.2217/bmm-2020-0282 · Cited by 2
Blood pressure monitoring through pharmacies and team-based care of hypertension
Santschi, V., Wuerzner, G., & Chioléro, A. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000073 · Cited by 2
Lowering the Norms for Blood Pressure
Taler, S. J. (2023) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2023.01.014 · Cited by 2
Metadata
- Authors
- Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J.
- Affiliations
- Memorial University of Newfoundland (CA)
- ORCID
- Venue
- Hypertension
- Published
- 2010-02
- Volume
- 55
- Issue
- 2
- Pages
- 195-200
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2171867406
- Cited by
- 260
- References
- 37
- Citations by year
- 2026: 2 · 2025: 7 · 2024: 7 · 2023: 8 · 2022: 4 · 2021: 17 · 2020: 18 · 2019: 22 · 2018: 31 · 2017: 27 · 2016: 34 · 2015: 16 · 2014: 15 · 2013: 14 · 2012: 19
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
- Keywords
- office blood pressure measurement, normotension, systolic hypertension, diastolic hypertension, cardiovascular outcomes, Framingham Heart Study, Multiple Risk Factor Intervention Trial
- MeSH terms
- Blood Pressure Determination, Female, Humans, Hypertension, Male, Office Visits, Ontario, Reference Standards, Risk Factors, Self Care, Reproducibility of Results, Blood Pressure Monitors, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review