CoChat

Detecting Sodium-Sensitivity in Hypertensive Patients: Information From 24-Hour Ambulatory Blood Pressure Monitoring

Open access
Castiglioni, Paolo, Parati, Gianfranco, Brambilla, Lorenzo, Brambilla, Valerio, Gualerzi, Massimo, Di Rienzo, Marco, Coruzzi, Paolo · 2011 · Hypertension
Cited by 59

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Sodium sensitivity is an important cardiovascular risk factor for which a diagnosis requires a time-consuming protocol, the implementation of which is often challenging for patients and physicians. Our aim was to assess the reliability of an easier approach based on data from 24-hour ambulatory blood pressure monitoring performed in hypertensive subjects during daily-life conditions and habitual diet. We enrolled 46 mild to moderate hypertensive subjects who underwent 24-hour ambulatory blood pressure monitoring during usual sodium intake. Patients were divided into 3 classes of sodium sensitivity risk on the basis of ambulatory blood pressure monitoring data: low risk if dippers and a 24-hour heart rate ≤70 bpm; high risk if nondippers and a 24-hour heart rate of >70 bpm; intermediate risk with the remaining combinations (dippers with heart rate >70 bpm or nondippers with heart rate ≤70 bpm). Then patients underwent a traditional sodium sensitivity test for the dichotomous classification as sodium sensitive or sodium resistant and for evaluating the sodium sensitivity index. Prevalence of sodium-sensitive patients and mean value of sodium sensitivity index were calculated in the 3 risk classes. The sodium sensitivity index markedly and significantly increased from the low-risk to the high-risk class, being equal to 19.9±14.4, 37.8±8.3, and 68.3±17.0 mm Hg/(mol/day) in the low-risk, intermediate-risk, and high-risk classes, respectively (M±SEM). Also, the prevalence of sodium-sensitive patients increased significantly from the low-risk class (25%) to the intermediate-risk (40%) and high-risk (70%) classes. Thus, performance of 24-hour ambulatory blood pressure monitoring in daily-life conditions and habitual diet may give useful information on the sodium sensitivity condition of hypertensive subjects in an easier manner than with the traditional sodium sensitivity test approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.110.158972

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 59

Metadata

Authors
Castiglioni, P., Parati, G., Brambilla, L., Brambilla, V., Gualerzi, M., Di Rienzo, M., & Coruzzi, P.
Venue
Hypertension
Published
2011-02
Volume
57
Issue
2
Pages
180-185
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2119302001
Cited by
59
References
3
FWCI
4.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting Sodium-Sensitivity in Hypertensive Patients: Information From 24-Hour Ambulatory Blood Pressure Monitoring. https://app.cochat.ai/papers/10.1161/hypertensionaha.110.158972
The paper
Castiglioni, P., Parati, G., Brambilla, L., Brambilla, V., Gualerzi, M., Di Rienzo, M., & Coruzzi, P. (2011). Detecting Sodium-Sensitivity in Hypertensive Patients: Information From 24-Hour Ambulatory Blood Pressure Monitoring. Hypertension. https://doi.org/10.1161/hypertensionaha.110.158972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.