Appropriate Time Interval to Repeat Ambulatory Blood Pressure Monitoring in Patients With White-Coat Resistant Hypertension
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Resistant hypertension is defined as uncontrolled office blood pressure, despite the use of ≥3 antihypertensive drugs. Ambulatory blood pressure monitoring (ABPM) is mandatory to diagnose 2 different groups, those with true and white-coat resistant hypertension. Patients are found to change categories between controlled/uncontrolled ambulatory pressures without changing their office blood pressures. In this way, ABPM should be periodically repeated. The aim of this study was to evaluate the most appropriate time interval to repeat ABPM to assure sustained blood pressure control in patients with white-coat resistant hypertension. This prospective study enrolled 198 patients (69% women; mean age: 68.9±9.9 years) diagnosed as white-coat resistant hypertension on ABPM. Patients were submitted to a second confirmatory examination 3 months later and repeated twice at 6-month intervals. Statistical analyses included Bland-Altman repeatability coefficients and multivariate logistic regression. Mean office blood pressure was 163±20/84±17 mm Hg, and mean 24-hour blood pressure was 118±8/66±7 mm Hg. White-coat resistant hypertension diagnosis presented a moderate reproducibility and was confirmed in 144 patients after 3 months. In the third and fourth ABPMs, 74% and 79% of patients sustained the diagnosis. In multivariate regression, a daytime systolic blood pressure ≤115 mm Hg in the confirmatory ABPM triplicated the chance of white-coat resistant hypertension status persistence after 1 year. In conclusion, a confirmatory ABPM is necessary after 3 months of the first white-coat–resistant hypertension diagnosis, and the procedure should be repeated at 6-month intervals, except in patients with daytime systolic blood pressure ≤115 mm Hg, in whom it may be repeated annually.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
de la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809
Mancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
PIERDOMENICO, S., LAPENNA, D., BUCCI, A., DITOMMASO, R., DIMASCIO, R., MANENTE, B., CALDARELLA, M., NERI, M., CUCCURULLO, F., & MEZZETTI, A. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.05.014 · Cited by 409 · cited 1×
“Nighttime SBP, mm Hg 108 (11) 107 (12) 112 (8) 0.”
Prognostic Influence of Office and Ambulatory Blood Pressures in Resistant Hypertension
Salles, G. F., Cardoso, C. R. L., & Muxfeldt, E. S. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.21.2340 · Cited by 293
Self-citationPrognostic Value of Nocturnal Blood Pressure Reduction in Resistant Hypertension
Muxfeldt, E. S., Cardoso, C. R. L., & Salles, G. F. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.68 · Cited by 155
Self-citation
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Drawz, P. E., Alper, A. B., Anderson, A. H., Brecklin, C. S., Charleston, J., Chen, J., Deo, R., Fischer, M. J., He, J., Hsu, C.-Y., et al. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.08530815 · Cited by 199
Metadata
- Authors
- Muxfeldt, E. S., Fiszman, R., de Souza, F., Viegas, B., Oliveira, F. C., & Salles, G. F.
- Venue
- Hypertension
- Published
- 2012-02
- Volume
- 59
- Issue
- 2
- Pages
- 384-389
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2027469867
- Cited by
- 59
- References
- 6
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Appropriate Time Interval to Repeat Ambulatory Blood Pressure Monitoring in Patients With White-Coat Resistant Hypertension. https://app.cochat.ai/papers/10.1161/hypertensionaha.111.185405
- The paper
- Muxfeldt, E. S., Fiszman, R., de Souza, F., Viegas, B., Oliveira, F. C., & Salles, G. F. (2012). Appropriate Time Interval to Repeat Ambulatory Blood Pressure Monitoring in Patients With White-Coat Resistant Hypertension. Hypertension. https://doi.org/10.1161/hypertensionaha.111.185405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.