CoChat

Murine Recombinant Angiotensin-Converting Enzyme 2: Effect on Angiotensin II–Dependent Hypertension and Distinctive Angiotensin-Converting Enzyme 2 Inhibitor Characteristics on Rodent and Human Angiotensin-Converting Enzyme 2

Open access
Ye, Minghao, Wysocki, Jan, Gonzalez-Pacheco, Francisco R., Salem, Mahmoud, Evora, Karla, Garcia-Halpin, Laura, Poglitsch, Marko, Schuster, Manfred, Batlle, Daniel · 2012 · Hypertension
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A newly produced murine recombinant angiotensin (Ang)-converting enzyme 2 (ACE2) was characterized in vivo and in vitro. The effects of available ACE2 inhibitors (MLN-4760 and 2 conformational variants of DX600, linear and cyclic) were also examined. When murine ACE2 was given to mice for 4 weeks, a marked increase in serum ACE2 activity was sustainable. In acute studies, mouse ACE2 (1 mg/kg) obliterated hypertension induced by Ang II infusion by rapidly decreasing plasma Ang II. These effects were blocked by MLN-4760 but not by either form of DX600. In vitro, conversion from Ang II to Ang-(1-7) by mouse ACE2 was blocked by MLN-4760 (10 −6 m ) but not by either form of DX600 (10 −5 m ). Quantitative analysis of multiple Ang peptides in plasma ex vivo revealed formation of Ang-(1-9) from Ang I by human but not by mouse ACE2. Both human and mouse ACE2 led to the dissipation of Ang II with formation of Ang (1-7). By contrast, mouse ACE2-driven Ang-(1-7) formation from Ang II was blocked by MLN-4760 but not by either linear or cyclic DX600. In conclusion, sustained elevations in serum ACE2 activity can be accomplished with murine ACE2 administration, thereby providing a strategy for ACE2 amplification in chronic studies using rodent models of hypertension and cardiovascular disease. Human but not mouse ACE2 degrades Ang I to form Ang-(1-9). There are also species differences regarding rodent and human ACE2 inhibition by known inhibitors such that MLN-4760 inhibits both human and mouse ACE2, whereas DX600 only blocks human ACE2 activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.112.198622

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 107

Metadata

Authors
Ye, M., Wysocki, J., Gonzalez-Pacheco, F. R., Salem, M., Evora, K., Garcia-Halpin, L., Poglitsch, M., Schuster, M., & Batlle, D.
Venue
Hypertension
Published
2012-09
Volume
60
Issue
3
Pages
730-740
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2106243495
Cited by
107
References
1
FWCI
3.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Murine Recombinant Angiotensin-Converting Enzyme 2: Effect on Angiotensin II–Dependent Hypertension and Distinctive Angiotensin-Converting Enzyme 2 Inhibitor Characteristics on Rodent and Human Angiotensin-Converting Enzyme 2. https://app.cochat.ai/papers/10.1161/hypertensionaha.112.198622
The paper
Ye, M., Wysocki, J., Gonzalez-Pacheco, F. R., Salem, M., Evora, K., Garcia-Halpin, L., Poglitsch, M., Schuster, M., & Batlle, D. (2012). Murine Recombinant Angiotensin-Converting Enzyme 2: Effect on Angiotensin II–Dependent Hypertension and Distinctive Angiotensin-Converting Enzyme 2 Inhibitor Characteristics on Rodent and Human Angiotensin-Converting Enzyme 2. Hypertension. https://doi.org/10.1161/hypertensionaha.112.198622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.