Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 372

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

New Gestational Phase–Specific Cutoff Values for the Use of the Soluble fms-Like Tyrosine Kinase-1/Placental Growth Factor Ratio as a Diagnostic Test for Preeclampsia

Verlohren, Stefan, Herraiz, Ignacio, Lapaire, Olav, Schlembach, Dietmar, Zeisler, Harald, Calda, Pavel, Sabria, Joan, Markfeld-Erol, Filiz, Galindo, Alberto, Schoofs, Katharina, Denk, Barbara, Stepan, Holger·2014·Hypertension

Abstract

To establish gestational phase adapted cutoffs for the use of the soluble fms-like tyrosine kinase-1 (sFlt-1)/placental growth factor (PlGF) ratio as a diagnostic tool for preeclampsia in the clinical setting, a multicenter case–control study including a total of 1149 patients was performed. We report normal values of sFlt-1, PlGF, and the sFlt-1/PlGF ratio based on the analysis of a total of 877 patients with uneventful pregnancy outcome. A total of 234 patients with preeclampsia and a matched cohort consisting of 468 patients with normal pregnancy outcome were compared, and sFlt-1 and PlGF were measured on an automated platform. Separate cutoffs for the sFlt-1/PlGF ratio were determined for the early (20+0–33+6 weeks) and the late gestational phase (34+0 weeks–delivery). For each of the 2 gestational phases, 2 independent cutoffs framing an equivocal zone were determined: the first cutoff with focus on high sensitivity, and the second focusing on high specificity. Between 20+0 and 33+6 weeks, the cutoffs at ≤33 and ≥85 resulted in a sensitivity/specificity of 95%/94% and 88%/99.5%, respectively. An sFlt-1/PlGF ratio of ≤33 had the lowest likelihood of a negative test (0.05; 95% confidence interval, 0.02–0.13), whereas values ≥85 had the highest likelihood of a positive test (176; 95% confidence interval, 24.88–1245). After 34+0 weeks, the cutoffs at ≤33 and ≥110 yielded a sensitivity/specificity of 89.6%/73.1% and 58.2%/95.5%, respectively. The approach to use multiple cutoffs for the early and late gestational phase enhances the diagnostic accuracy of the sFlt-1/PlGF ratio as a diagnostic tool for preeclampsia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.113.01787

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 372

Metadata

Authors
Verlohren, S., Herraiz, I., Lapaire, O., Schlembach, D., Zeisler, H., Calda, P., Sabria, J., Markfeld-Erol, F., Galindo, A., Schoofs, K., Denk, B., & Stepan, H.
Venue
Hypertension
Published
2014-02
Volume
63
Issue
2
Pages
346-352
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2170867031
Cited by
372
References
23
FWCI
20.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New Gestational Phase–Specific Cutoff Values for the Use of the Soluble fms-Like Tyrosine Kinase-1/Placental Growth Factor Ratio as a Diagnostic Test for Preeclampsia. https://app.cochat.ai/papers/10.1161/hypertensionaha.113.01787
The paper
Verlohren, S., Herraiz, I., Lapaire, O., Schlembach, D., Zeisler, H., Calda, P., Sabria, J., Markfeld-Erol, F., Galindo, A., Schoofs, K., Denk, B., & Stepan, H. (2014). New Gestational Phase–Specific Cutoff Values for the Use of the Soluble fms-Like Tyrosine Kinase-1/Placental Growth Factor Ratio as a Diagnostic Test for Preeclampsia. Hypertension. https://doi.org/10.1161/hypertensionaha.113.01787

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.